Boiler Siting and Location Rules: Flue Terminals, Bedrooms, Cupboards and Garages
Where a boiler may go: Regulation 30 of the Gas Safety (Installation and Use) Regulations 1998 (room-sealed only in bathrooms and shower rooms; room-sealed in sleeping accommodation, with the 14 kW gross atmosphere-sensing alternative) and BS 7671 Section 701 zones; fanned-flue terminal clearances from BS 5440-1:2008 and Approved Document J Diagram 35 (300 mm from openings, ground and corners, 75 mm below gutters, 200 mm below eaves, 600 mm from a facing surface, 1,200 mm from a facing terminal, guards below 2 m) and plume management; flues in voids and TB 008 inspection hatches; cupboards and airing cupboards with manufacturer clearances, BS 5440-2:2023 cooling vents and the 13 mm perforated partition; loft installations under BS 6798:2014 (fixed access, boarded platform, guard rail, lighting, isolation at the hatch, frost protection); garages and outbuildings; condensate in 22 mm internally or 32 mm insulated externally and PRV discharge; the electrical spur; the CO alarm requirement in Approved Document J since 1 October 2022; and notification.