Carbon Monoxide Safety: Alarm Placement, Flue Checks & Landlord Obligations

Quick Answer: Carbon monoxide (CO) is an odourless, colourless gas produced by incomplete combustion. CO alarms must be fitted in any room containing a fixed combustion appliance (gas boiler, gas fire, wood burner, oil boiler) under the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 (England). Alarms must comply with BS EN 50291-1. Scotland has required CO alarms since 2022 under the Tolerable Standard. Landlords must install CO alarms and test them at the start of each tenancy.

Summary

Carbon monoxide poisoning kills around 40–50 people in the UK each year and causes hundreds more to be hospitalised or suffer lasting health effects. The tragedy is that most of these deaths are preventable with a functioning CO alarm. Despite this, CO alarm fitting is inconsistently applied, and many gas engineers still don't advise clients strongly enough about the need for CO detection adjacent to every combustion appliance.

CO is produced when any fuel (gas, oil, wood, coal) burns incompletely due to restricted air supply, incorrect burner adjustment, or a blocked or damaged flue. The critical danger is that CO has no smell, taste, or colour — by the time symptoms appear (headache, dizziness, nausea), significant exposure has already occurred. People have died without waking from sleep because CO levels were not high enough to trigger obvious symptoms before incapacitation.

For gas engineers in particular, understanding CO — its sources, how to test for it, and how to advise clients — is part of professional competence. Checking combustion efficiency and CO levels in flue gases at every service and installation is best practice, and identifying sources of CO risk before they become dangerous is part of the duty of care to clients.

Key Facts

Quick Reference Table

Need to quote gas work? squote generates accurate, professional quotes fast.

Try squote free →
CO Level (ppm) Effect Alarm Action Required?
0–9 Normal ambient (typical urban air <1–3 ppm) No
10–50 Low but notable; investigate source BS EN 50291-1 alarm may not trigger; investigate
50 Occupational exposure limit (8h TWA) Alarms may begin to trigger (exposure-dependent)
100–200 Headache, dizziness within 2–3 hours Alarm should trigger
200–400 Severe headache, vomiting; incapacitation within 1 hour Alarm triggers
400+ Life-threatening within 1 hour Alarm triggers — evacuate immediately
1600+ Death within 1 hour

Detailed Guidance

CO Alarm Placement

BS EN 50292 recommends:

Minimum required positions (England, Smoke and CO Alarm Regulations 2022):

Common placement for boilers: if the boiler is in a kitchen, position the CO alarm on the ceiling between the boiler and the sleeping areas — typically in the hallway outside the kitchen, or on the landing if the boiler is on the ground floor. This provides early warning before CO reaches sleeping occupants.

For wood burners and multi-fuel stoves: fit a CO alarm in the same room as the appliance AND on the landing above. CO from stoves can accumulate in sleeping areas via air leakage around doors.

Flue Spillage Testing

Gas appliances with open flues (traditional gas fires, back boilers, older boilers) can "spill" combustion products into the room if the flue is blocked, the draught is insufficient, or the appliance is in a very airtight room.

Open flue check procedure (at every service):

  1. With appliance running, hold a smoke match or smoke pencil at the draught diverter or draught hood — smoke should be drawn in
  2. If smoke is blown out, there is flue spillage — investigate: blocked flue, flue terminal obstruction, inadequate air supply
  3. Close all doors and windows — if spillage stops, the room is too airtight; ventilation is required
  4. If spillage persists, use a CO analyser at the draught diverter — any reading above 10 ppm suggests a spillage issue; above 50 ppm is potentially dangerous

Room-sealed appliances (balanced flue boilers) cannot spill combustion products into the room — all combustion air is drawn from outside and all flue gases are discharged outside. However, a cracked or damaged heat exchanger can still allow CO into the heated water (not typically dangerous) or, more rarely, into the room if the flue system has a defect.

Combustion Analysis at Service

Every service of a gas appliance should include combustion analysis with a calibrated flue gas analyser. Check:

A CO/CO₂ ratio above 0.004 is a warning sign. Above 0.01 (1%), investigate immediately. This is an "at risk" (AR) situation under the Gas Industry Unsafe Situations Procedure.

Suspected CO Poisoning — What to Do

If you suspect a client has been exposed to CO (they report persistent headaches, flu-like symptoms without fever, symptoms that improve when away from home):

  1. Advise them to leave the property immediately — get into fresh air
  2. Do not re-enter until the source has been identified and isolated
  3. Seek medical attention — CO poisoning requires hyperbaric oxygen treatment in severe cases; blood CO level (carboxyhaemoglobin) should be measured at A&E
  4. Call 999 if symptoms are severe (confusion, loss of consciousness, vomiting)
  5. Call the gas emergency line (0800 111 999 for National Gas Emergency) to report a suspected gas/CO leak
  6. If you are the attending gas engineer: test ambient air CO levels with a CO detector, find and isolate the source, classify as ID or AR as appropriate, label the appliance, and record everything

Landlord Obligations (England)

Under the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022:

Best practice for landlords: document CO alarm testing in the tenancy check-in report with a photograph showing the alarm and its battery/test status. Replace CO alarms at their end-of-life date (check manufacture date on the back).

Frequently Asked Questions

Where exactly should I fit a CO alarm in a room with a boiler?

Ceiling-mounted between 300mm and 3m from the boiler (not directly above it — that position can give elevated readings during normal operation). For a boiler in a kitchen, fit on the ceiling in the hallway just outside the kitchen door, so it protects the sleeping areas above without being in the highest-activity area.

Can a CO alarm substitute for a gas leak detector?

No. CO alarms detect carbon monoxide — a combustion product. They do not detect natural gas or LPG leaks (methane, propane, butane). A gas alarm for unburned gas is a separate device (methane detector or combined unit). CO alarms and gas alarms are different products with different sensors.

My client's CO alarm keeps going off but there's no source I can find — why?

Several possibilities: (1) the alarm is at end of life and the sensor has degraded, causing false triggers — check the manufacture date and replace if >5–7 years old; (2) low-level CO from a vehicle in a garage below the room; (3) neighbours burning waste near air bricks; (4) a very minor flue defect not detectable on visual inspection — use a combustion analyser and do a full flue spillage test; (5) the alarm is responding to solvents or cleaning products (unlikely with a good-quality alarm, but possible with cheaper units).

Is a CO alarm on its own sufficient protection?

No — alarms are the last line of defence. The primary protection is: correct installation and commissioning of all gas appliances by Gas Safe registered engineers, annual servicing, working flue and ventilation, and correct combustion at the burner. A CO alarm is essential but should not substitute for maintaining appliances correctly.

Regulations & Standards