Summary
The Pulsar Plus is one of the smallest and most widely fitted home chargers in the UK, sold tethered in 5 m and 7 m lengths at 7.4 kW single-phase (a 22 kW three-phase version exists and is common in Ireland and Europe). It has no screen and no buttons: everything is done through the LED halo around the cable gland and the Wallbox app, which talks to the charger over Bluetooth when you are standing next to it and over Wi-Fi via the Wallbox cloud when you are not. That architecture explains a large share of "faults": a Bluetooth pairing that has been lost, a 2.4 GHz Wi-Fi network that has been renamed, or an app that is looking at the cloud while the charger is offline.
Genuine faults are signalled by a red halo. Wallbox's own documentation describes red as a detected safety issue with the electrical connection or the vehicle and tells users not to attempt to charge, and the app shows a numeric error code. Wallbox publishes meanings for only a few codes; third-party sites list many more, often contradicting each other, so this article sticks to what Wallbox itself documents and gives you the electrical method for everything else.
For the brand-independent branch (supply, RCD type, Control Pilot, PME earthing) see ev charger faults and ev charger fault finding. For how the Pulsar compares with zappi, Ohme and Hypervolt see ev charger brands compared.
Key Facts
- Models — Pulsar Plus (2019 onward; 7.4 kW single-phase or 22 kW three-phase; tethered Type 2, 5 m or 7 m), Pulsar Plus Socket (untethered, some markets), Pulsar Max (2022 onward; 7.4 kW or 22 kW; larger body, same LED language, higher ingress protection). A revised Pulsar Plus hardware version (PUP2) ships with the halo switched off by default to meet standby-power rules, so a dark halo on a new unit can be normal.
- No screen — status is the LED halo; diagnostics are in the Wallbox app (formerly myWallbox). Bluetooth is used for local setup and control; Wi-Fi (2.4 GHz) or an optional Ethernet adapter for cloud features.
- Red halo = fault — the charger has detected a safety issue with the electrical connection or the vehicle. Wallbox's instruction is not to charge and to contact support if the code does not clear.
- Error 101 — connection or internal fault. Wallbox's fix: restart the charger, then use the app's restore function.
- Error 102 — relay stuck closed (output contactor welded or not releasing). Wallbox's fix: power cycle at the breaker. If it recurs the contactor has failed and the unit is a warranty claim.
- Red for about 30 seconds (Power Sharing) — secondary chargers misconfigured; the problem originates at the primary unit's configuration, not at the secondary that shows red.
- Blinking turquoise (Power Boost) — the car is waiting for power to become available under dynamic load management; charging starts when household load falls.
- Blinking orange (MID meter) — communication between the charger and its MID-approved energy meter has failed (Power Boost or Power Sharing installations only).
- Integrated PEN fault protection (UK units) — Wallbox's UK material states the Pulsar Plus connects directly to a PME supply with no earth rod, using the Regulation 722.411.4.1 voltage-monitoring method.
- 6 mA DC leakage detection built in — allows a Type A upstream RCD. The datasheet still lists an external Type A RCCB as required; the Pulsar does not replace the circuit RCD.
- Current limit 6–32 A — set in the app at commissioning. A customer complaining of slow charging may have a unit left at 16 A or capped by Power Boost.
- Smart Charge Points Regulations 2021 — UK units sold from 30 June 2022 ship with a default off-peak schedule and a randomised start delay of up to 600 seconds. Blinking turquoise with nothing happening is often this.
- Lock — yellow halo. The charger will not start a session until unlocked in the app; Wallbox also offers auto-lock.
- Firmware — solid white is an update in progress. Do not isolate the unit during an update.
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Halo | Meaning | Fault? | First action |
|---|---|---|---|
| Green, solid | Powered and ready, no vehicle | No | None |
| Turquoise, solid | Vehicle connected, communication established, waiting | No | Check schedule, lock and Power Boost headroom |
| Turquoise, blinking | Scheduled session ready to start, or Power Boost waiting for available power | No | Edit or cancel schedule; reduce household load |
| Dark blue, pulsing | Charging | No | None |
| Yellow | Locked | No | Unlock in app |
| White, solid | Firmware updating | No | Wait; do not isolate |
| Orange, blinking | MID meter communication error | Yes (configuration) | Check meter wiring (RS-485 polarity) and meter settings |
| Red, about 30 s then clears | Power Sharing: secondaries misconfigured | Yes (configuration) | Reconfigure at the primary charger |
| Red, steady | Safety issue with electrical connection or vehicle | Yes | Read code in app; 101 restart and restore; 102 power cycle at breaker; otherwise test installation |
| Off | PUP2 hardware with halo disabled, or no power | Maybe | App online = normal; app offline and dark = check RCBO and isolator |
Detailed Guidance
Decision tree
PULSAR WON'T CHARGE
===================
1. Halo colour?
Turquoise / yellow -> go to 2 (settings)
Green with car plugged in -> go to 3 (no handshake)
Red -> go to 4 (fault)
Off -> go to 5 (power or PUP2)
App won't connect at all -> go to 6 (Bluetooth/Wi-Fi)
2. SETTINGS
- Yellow: locked. Unlock in app (or check auto-lock).
- Turquoise solid: waiting. Check schedule; check Power Boost
headroom (CT reading vs house limit); check car's own timer.
- Turquoise blinking: scheduled or waiting for power. Cancel
schedule to test; switch off a high load (shower, oven).
- Charges after override -> healthy.
3. GREEN WITH CAR CONNECTED (no Control Pilot handshake)
- Reseat plug; inspect pins for water, debris, bent CP pin.
- Check car's charge port flap sensor and charge limit.
- Try car on another charger; try another car on this one.
- Still green -> cable or CP circuit fault in unit, warranty.
4. RED
a. Read the code in the app.
101 -> restart charger, then "Restore" in app.
102 -> isolate at breaker 30 s, restore. Recurs -> relay
failed, warranty.
Other code -> note it exactly, then b-d.
b. Red with no car connected -> supply. Measure L-N (207-253 V)
and N-E at terminals. Out of range = PEN/DNO issue.
c. Red only with one car -> vehicle DC leakage or cable.
d. Upstream RCD/RCBO also tripped -> earth fault; IR test the
circuit with charger disconnected.
5. HALO OFF
- PUP2: app online -> normal; enable halo in app if wanted.
- App offline: check RCBO, external isolator, 230 V at terminals.
6. CAN'T CONNECT
- Stand within 2 m, Bluetooth ON, location permission granted.
- Wi-Fi: 2.4 GHz only; SSID/password changed?; router rebooted?
- Charger may be fine and charging locally. Confirm at the car.
Red halo: working through it electrically
Wallbox's documentation is deliberately brief about the red state. From the installer's side it covers the same protective functions as every UK charger:
- Open-PEN and voltage window. The Pulsar's PEN protection works by monitoring the supply voltage. A supply that sits above 253 V (common with large PV exports on rural networks) or dips under load because of a poor termination will trip it. Measure L–N with and without a 3 kW load; measure N–E. A rising N–E voltage with a drifting L–N is a broken PEN on the DNO network: make safe and call 105. Do not reset repeatedly.
- DC residual current. The 6 mA RDC-DD trips on DC leakage from the vehicle's on-board charger. If red appears only with one car and clears with another, the vehicle is the fault.
- Relay (error 102). The output contactor has stayed closed after the session ended, or has not opened on command. One power cycle is Wallbox's remedy; a second occurrence means the contactor is damaged and the unit must come off the wall under warranty. Never leave a charger in service with a known stuck relay: the cable is live with no car connected.
- Internal or connection fault (error 101). Covers loss of communication between the charger's boards or with the cloud during a session. Restart, then "Restore" from the app. If it recurs daily, check the Wi-Fi signal and the supply for brown-outs before condemning the unit.
- Upstream RCD trip. A dark halo with the RCBO off is an earth fault on the circuit or the vehicle, not a charger "error". Reset once; if it trips again, isolate and test. See rcd types explained for why a Type AC device is not acceptable here.
Power Boost and Power Sharing faults
Power Boost uses a MID meter clamped or wired on the incoming supply to throttle the charger below the house limit set in the app. Blinking turquoise with the car "not charging" means household load is at the limit; it is working. Blinking orange means the charger cannot talk to the meter: check the RS-485 A/B polarity, the meter's address and baud settings, and that the correct meter model is selected in the installer menu. Power Sharing links several Pulsars on one supply; a red halo for about 30 seconds after power-up on the secondaries means the primary's configuration (number of secondaries, current limits) is wrong. See load management explained.
Bluetooth and Wi-Fi: the non-electrical "faults"
The app pairs by Bluetooth, so the phone must be within a couple of metres with Bluetooth and location permissions enabled. Cloud features need 2.4 GHz Wi-Fi; a router that has been replaced, renamed or set to 5 GHz-only will take the charger offline. An offline Pulsar still charges when a car is plugged in, unless a schedule or lock is active. Confirm what the customer actually cannot do before booking an electrician's visit.
Installation checks when red keeps returning
- Safe isolation to GS38 (safe isolation procedure).
- Terminal torque on L, N and E; the Pulsar's compact terminal block is unforgiving of loose conductors, and heat marks on the insulation are a tell.
- Supply voltage under load and N–E voltage.
- Earthing: PME with integrated protection, or TT with an electrode and the earthing selected accordingly in the installer menu. See pme earthing ev charging.
- Upstream 30 mA Type A RCD or RCBO, trip-tested at 1× and 5× IΔn.
- Insulation resistance of the circuit with the charger disconnected, 500 V DC, 1 MΩ minimum.
- Zs and prospective fault current against the commissioning certificate (ev charger testing commissioning).
Healthy readings plus a red halo with no vehicle connected is an internal fault. Record the code and contact Wallbox; the unit is sealed and not user-repairable.
Frequently Asked Questions
Is there a full list of Wallbox error codes?
Wallbox publishes meanings for a small number of app codes, including 101 and 102, and treats the rest through its support channel. Lists on third-party websites disagree with each other and with Wallbox's own material, so do not act on them. Record the exact code shown in the app and work through the electrical checks above; if they pass, raise it with Wallbox support quoting the code and the charger serial.
Does the Pulsar Plus need an earth rod?
Not on a UK PME supply. Wallbox's UK documentation states the unit has integrated PEN fault protection using the voltage-monitoring method permitted by BS 7671:2018+A4:2026 Regulation 722.411.4.1. The installer must still confirm the supply type, fit the upstream Type A RCD or RCBO, and record the arrangement on the certificate.
The halo is off on a brand-new unit. Is it dead?
Possibly not. The PUP2 hardware revision ships with the halo disabled to meet standby energy rules. If the app shows the charger online, the unit is fine and the halo can be turned on in settings. If the app shows it offline and nothing happens when a car is plugged in, check the RCBO and isolator.
My customer says it charges slowly. Is that a fault?
Check the maximum current setting first. Installers sometimes leave a unit at 16 A or 20 A, and Power Boost will cap the charger whenever the house is busy. A 7.4 kW Pulsar charging at 3.6 kW with no error is almost always a settings or load-management outcome.
Can I reset error 102 and carry on?
Once, by isolating at the breaker. Error 102 means the output relay did not open, which leaves the tethered plug live with no car connected. If it recurs the unit must be taken out of service and replaced under warranty.
Regulations & Standards
BS 7671:2018+A4:2026 — Section 722; Regulation 722.411.4.1 (PME supplies and open-PEN protection); Regulation 722.531.3.101 (RCD type and DC fault detection).
IET Code of Practice for Electric Vehicle Charging Equipment Installation (5th edition, 2023).
Electric Vehicles (Smart Charge Points) Regulations 2021 — default off-peak schedule and randomised delay on UK units sold from 30 June 2022.
BS EN IEC 61851-1 — Mode 3 conductive charging and Control Pilot signalling.
BS EN IEC 62196-2:2026 — Type 2 connectors.
BS EN 62955 — residual direct current detecting devices (RDC-DD).
Building Regulations 2010, Approved Document P — notification of new charger circuits in England and Wales.
Electricity Safety, Quality and Continuity Regulations 2002 — DNO supply voltage limits and PEN integrity duties.
Wallbox Help Center: Pulsar Plus status LED colours — official halo meanings.
Wallbox Help Center: Understanding Wallbox app error codes — codes 101 and 102.
Wallbox Help Center: Troubleshooting guide for all Wallbox chargers — connectivity and reset steps.
Wallbox UK: Pulsar Plus earthing solution — integrated PEN fault protection statement.
Wallbox Pulsar Plus datasheet — external Type A RCCB requirement and DC leakage protection.
The Electric Vehicles (Smart Charge Points) Regulations 2021
ev charger faults — brand-agnostic EV charger fault diagnosis.
ev charger fault codes zappi — myenergi zappi codes.
ev charger fault codes hypervolt — Hypervolt LED states and red-light diagnosis.
ev charger fault codes easee — Easee self-test codes and LED patterns.
load management explained — how Power Boost and Power Sharing style load management works.
pme earthing ev charging — PEN fault protection options.