Summary

Easee is a Norwegian brand that sold in volume in the UK from 2021 and gained a reputation for the smallest wall unit on the market, a built-in SIM for 4G connectivity (so it does not rely on home Wi-Fi), and a modular "backplate plus charging unit" design that lets a faulty unit be swapped in minutes. It also carries more protection inside the box than most rivals: an integrated RCD rated for 30 mA AC and 6 mA DC, open-PEN detection, and continuous self-tests that produce numbered error codes. That is helpful for diagnosis, and it is also why Easee attracted regulatory attention in 2023, when the Swedish electrical safety authority banned sales of the Home and Charge models over the design of the integrated RCD. Easee disputed the findings; the Easee One, launched for the UK with a revised RCD design and UK-specific PEN protection, is the current product.

Like every smart charger, most Easee call-outs are not faults. The unit is often waiting for a schedule, for an authorisation (the car is plugged in but the owner has not tapped their key or enabled charging without authentication), or for the Equalizer load-balancer to free up current. The LED strip tells you which, and the app's warning text names any real fault.

This article covers the Easee LED language, the self-test codes, the named app warnings and how to resolve each one on site. For the brand-independent branch see ev charger faults and ev charger fault finding.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Indication Where Meaning First action
Steady white LED strip Standby, no car connected None
Steady blue LED strip Car connected, not charging: awaiting authorisation, schedule, smart charging or load limit Tap key; check schedule and Equalizer limit
Pulsing blue LED strip Charging None
Brief red blink after tap LED strip Charge authorisation rejected Check user and key permissions in app
Red blinking on/off, persistent LED strip Fault: read the warning in the app Read app; follow the warning
Red slowly pulsing (brightening and dimming) LED strip Safe mode, charger blocked from use Read app; isolate and investigate
Steady red LED strip Charger error Read app; reboot once; contact support if persistent
Red flashing with warning sounds LED strip Critical error, charger locked, cannot be reset by user Stop using; isolate; contact Easee
Steady red with warning sounds LED strip Wires connected incorrectly or broken PEN Isolate; check polarity and PEN; electrician only
Code 2 App self-test Failed to connect to cellular network Check 4G signal; use Wi-Fi
Code 3 App self-test Failed to connect to Wi-Fi Check 2.4 GHz network and password
Code 4 App self-test Easee Link radio not working Affects load balancing between units; contact support
Code 5 App self-test Power board not responding Reboot once; replace charging unit
Code 7 App self-test Error reading backplate RFID tag Reseat charging unit; replacement backplate tag
Code 9 App self-test Cable lock fault Do not force; check socket for debris; replace unit
Code 10 App self-test Pilot signal fault Try another cable and car; then unit
Code 11 App self-test RCD self-test failed Isolate; unit replacement
Code 12 / 13 App self-test Relay failed to open / close Isolate; unit replacement
Code 14 App self-test Temperature reading fault Unit replacement
Code 15 App self-test Current sensor reading fault Unit replacement
"Overcurrent" App warning Car drew more than allowed Unplug and retry; check car's charger behaviour
"Ground fault" App warning Earth fault between car and charger Reconnect; try another cable; then car
"Insulation fault" App warning Fault in cable, connector or car Another cable; another car
"Incoming supply issue" App warning Voltage outside 207–253 V Measure; DNO if persistent
"High temperature" App warning Charger paused on temperature Check sun exposure, ventilation, terminal heating
"Power grid change" / "Invalid grid" App warning Grid configuration changed or not detected Reboot; check wiring and installer grid setting
"Critical fault" App warning Charger permanently locked Contact Easee

Detailed Guidance

Decision tree

EASEE WON'T CHARGE
==================
1. Strip colour?
   Steady blue -> go to 2 (waiting)
   Steady white with car plugged in -> go to 3 (no handshake)
   Any red -> go to 4 (fault)
   Nothing lit -> go to 5 (power)

2. WAITING
   - Authorisation: tap RFID key or approve in app; enable
     "charge without authentication" if the customer wants it.
   - Schedule: check smart charging / schedule in app.
   - Equalizer or circuit limit: app shows available current.
     0 A = house at its limit or Equalizer fault (code 4 / comms).
   - Car's own timer or charge limit.
   - Random delay (up to 10 min) on UK units.
   - Charges after override -> healthy.

3. NO HANDSHAKE
   - Reseat cable both ends; inspect CP pin; try another cable.
   - Code 10 in self-test -> pilot fault in unit.
   - Car on another charger OK and cable OK -> unit.

4. RED
   a. Brief blink after key tap -> permissions, not a fault.
   b. Open the app. Named warning?
      Overcurrent / ground fault / insulation fault -> vehicle or
        cable: swap cable, swap car, then unit.
      Incoming supply issue -> measure L-N and N-E at terminals.
      High temperature -> environment, terminal torque, current.
      Power grid change / invalid grid -> reboot; check installer
        grid-type setting and L/N wiring.
      Critical fault -> stop; isolate; Easee support.
   c. Warning sounds with steady red -> MISWIRING or BROKEN PEN.
      Isolate at once. Check L/N polarity, PEN/N-E voltage. DNO
      on 105 if the supply neutral is suspect.
   d. Run self-test in app; codes 5, 9-15 are hardware -> swap
      the charging unit on the backplate.

5. NOTHING LIT
   - RCBO/RCD at consumer unit; external isolator.
   - 230 V at backplate terminals (safe isolation first).
   - Power present -> charging unit dead; swap it.

The integrated RCD: what it does and does not replace

Easee's RCD is rated 30 mA AC and 6 mA DC, and the manufacturer's position is that it can provide the circuit's RCD protection if, and only if, the charger is the only equipment on that circuit and the installer identifies no other reason for an external device. In practice most UK installers still fit a Type A RCBO at the board, because BS 7671:2018+A4:2026 Regulation 722.531.3.101 requires RCD protection to be provided by a device complying with the recognised product standards, and many certification bodies and scheme inspectors expect to see one. If an upstream RCBO trips rather than the Easee itself, the fault is almost always on the vehicle or circuit, not the charger. See rcd types explained.

Self-test code 11 means the charger's own RCD failed its periodic self-test. The unit is not to be used and the charging unit is swapped; it is not a site-wiring fault.

Steady red with sound: miswiring and PEN

Easee's manuals link steady red with warning sounds to incorrect wiring or a broken PEN lead. On a new installation, check live and neutral polarity at the backplate first: a reversed L/N is the most common cause on day one and is the installer's error. On an existing installation that has worked for months, treat it as a supply fault. Measure line-to-neutral and neutral-to-earth at the terminals. A rising N–E voltage with L–N wandering indicates a broken PEN on the DNO network: isolate the charger, warn the customer about touching metalwork, and call the DNO on 105. Never repeatedly reboot a charger that is reporting a PEN fault.

Connectivity codes 2, 3 and 4

Code 2 means the built-in SIM cannot reach a 4G network. Garages with thick walls and metal doors are the usual cause; moving to Wi-Fi (code 3 if that fails) is the fix. An offline Easee will still charge if authentication is disabled or an RFID key is tapped, but schedules and dynamic load balancing need the cloud. Code 4 is the Easee Link radio between chargers failing; a single charger on its own is unaffected, but a pair sharing a circuit will fall back to a safe (low) current until it is resolved.

Overcurrent, ground fault and insulation fault

All three are detected on the output side and almost always originate in the cable or the vehicle. The quickest discrimination is to swap the cable (untethered sockets make this easy) and then to try a different car. A car that produces "ground fault" on two different chargers has a DC leakage or earth fault in its on-board charger and should be referred to the vehicle dealer. Document the warning text and time from the app for the customer.

Installation checks when the unit keeps faulting

  1. Safe isolation and proving dead to GS38 (safe isolation procedure).
  2. Polarity and torque at the backplate; Easee's terminals accept up to 16 mm² but a poorly stripped conductor heats and triggers "high temperature".
  3. L–N under load and N–E voltage; grid-type setting in the installer menu matches the supply (single-phase TN for a standard UK PME supply).
  4. Earthing arrangement and whether an upstream RCBO is fitted (pme earthing ev charging).
  5. Insulation resistance of the circuit with the charging unit removed from the backplate: 1 MΩ minimum at 500 V DC.
  6. Zs and prospective fault current against the commissioning certificate (ev charger testing commissioning).
  7. Run the app self-test and record every code before and after any change.

Frequently Asked Questions

Does the Easee One need an upstream RCD?

Easee says its integrated 30 mA AC / 6 mA DC RCD can serve as the circuit's protection only when the charger is the sole load on the circuit and the installer finds no other reason for an external device. Most UK installers fit a Type A RCBO at the board regardless, and scheme inspectors generally expect one. Follow the current Easee installer guide and BS 7671:2018+A4:2026 Section 722, and record your decision on the certificate.

Can I just swap the charging unit?

Yes, that is the design intent. The backplate carries the wiring and the RFID identity; the charging unit clips on and off. Hardware self-test codes (5, 9 to 15) are resolved by a replacement charging unit from Easee under warranty, with no rewiring. Code 7 (backplate RFID) needs a replacement tag or backplate.

The strip is red but the app shows nothing wrong. What now?

Run the self-test from the app and check whether the red was a brief blink after a key tap, which is a permissions message rather than a fault. If the strip stays red and the app has no warning, reboot once at the isolator. Persistent red with no warning is a hardware or connectivity problem for Easee support; record the LED pattern (blinking, pulsing, steady, with or without sound) because Easee's documentation distinguishes them.

Is my pre-2023 Easee Home safe after the Swedish ban?

The ban applied to sales in Sweden; UK units were not recalled and the UK did not issue a prohibition. The concern was the design of the integrated RCD and DC protection. Most UK installations also have an upstream Type A RCBO, which provides conventional protection. If a customer is worried, confirm the upstream RCBO is present and trip-tests correctly, and keep the firmware updated.

Why does it charge at 6 A with nothing else on?

Check the circuit current limit and the charger limit in the installer settings, the Equalizer's house limit if fitted, and whether code 4 is present (loss of Easee Link between units makes them fall back to a low current). A charger set to 6 A delivers about 1.4 kW.

Regulations & Standards