Summary

Hypervolt is a British-designed charger that sells heavily through installer networks and on its app features: solar matching (Eco and Super Eco modes), scheduling against time-of-use tariffs, a software lock and load management via a CT clamp. Like every smart charger, most of its "it's broken" call-outs are the charger doing what it was told: waiting for a schedule, waiting for surplus solar, or holding the mandatory random delay before a session starts. Reading the glow colour correctly and opening the app before touching a screwdriver will clear the majority of jobs in minutes.

Where Hypervolt differs from zappi, Pod Point or Ohme is in how it tells you about a genuine fault. There is no two-digit code on a display, because there is no display. The unit goes red, the app shows a status, and the troubleshooting is driven from the app's status text and the installation. That makes it important to know what the red state covers (RCD, open-PEN, over-voltage, under-voltage, output fault and internal protection) and how to narrow it down with a meter.

This article covers the Hypervolt-specific LED language, the app statuses, the protective functions inside the unit and the installation checks that resolve each red-light scenario. For the brand-agnostic branch (supply, RCD type, Control Pilot, PME earthing) see ev charger faults and ev charger fault finding.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
LED state Meaning Fault? First action
No light Plug-and-charge standby on some models (Home 3.0 quick-start guide), or no power Maybe Open the app: if it shows the charger online, standby; if offline and dark, check the RCBO and isolator
Solid blue Standby, ready, no vehicle connected (Home 2.0 and app descriptions) No None
Solid green Charging No None
Flashing green Randomised start delay before charging (Smart Charge Points Regulations 2021) No Wait up to 10 minutes; explain to customer
Solid purple Schedule set, no vehicle connected No Check schedule in app
Pulsing purple Vehicle connected, waiting for scheduled start No Use Boost or edit the schedule to charge now
Flashing yellow Super Eco waiting for surplus solar No Check CT clamp reading and export; switch to Eco or Boost to prove the unit charges
Solid orange Charger locked No Unlock in app or with paired card
Flashing orange Attempt to use a locked charger No Unlock; check who has access
Pulsing white No internet connection No (connectivity) Check router, Wi-Fi signal at the unit, Ethernet on Home 3 Pro
Solid or pulsing red Safety system activated; charging stopped Yes Isolator off 5 seconds, on; read app status; if red returns, test the installation (below)

Colours have shifted slightly between Home 2.0, Home 3.0 and Home 3 Pro firmware. Treat the app status as authoritative and the colour as a prompt.

Detailed Guidance

Decision tree

HYPERVOLT WON'T CHARGE
======================
1. What colour is the glow?
   Purple / yellow / orange / flashing green -> go to 2 (not a fault)
   Pulsing white -> go to 3 (offline)
   Red (solid or pulsing) -> go to 4 (safety trip)
   No light at all -> go to 5 (supply)

2. MODE OR SCHEDULE
   - Purple: schedule active. Press Boost in the app -> charges? Healthy.
   - Flashing yellow: Super Eco. Check live export in app; switch to
     Eco or Boost -> charges? Healthy; it's a solar question.
   - Orange: locked. Unlock in app.
   - Flashing green: random delay. Wait up to 10 min.
   - Still nothing after override -> go to 4

3. OFFLINE
   - Does the unit still charge in plug-and-charge? Yes -> connectivity only.
   - Check Wi-Fi signal at the unit (garage walls, metal doors).
   - Home 3 Pro: try Ethernet. Reboot router, then charger.
   - Reconnect via app onboarding if the home network changed.

4. RED - SAFETY TRIP
   a. Isolator OFF, wait 5 s, ON. Red clears and charging resumes?
      -> transient (voltage excursion, DC leakage event). Note and monitor.
   b. Red returns with NO car connected
      -> supply problem. Measure L-N at the unit: outside 207-253 V = PEN
         or DNO issue; inside range = internal fault, contact Hypervolt.
   c. Red returns ONLY with a particular car connected
      -> vehicle or cable: DC leakage from the on-board charger, damaged
         cable, water in the inlet. Test the car on another charge point.
   d. Upstream RCBO/RCD also tripped
      -> earth fault on circuit or vehicle. Insulation-resistance test the
         circuit with the charger disconnected; check RCD type (A minimum).

5. NO LIGHT, APP OFFLINE
   - Check dedicated RCBO/RCD at the consumer unit and the external isolator.
   - Confirm 230 V at the incoming terminals (safe isolation first).
   - Power present, still dark -> internal fault, warranty.

Red light: what the safety system is actually checking

The Hypervolt's red state is one indicator covering several independent protective functions, which is why the app status matters. The functions you can provoke or measure are:

Offline, but is it faulty?

Hypervolt's connectivity troubleshooting lists the usual suspects: a changed router or Wi-Fi password, a 2.4 GHz network that has been merged into a 5 GHz-only band, a mesh system that keeps dropping the unit, and signal that reads fine on a phone at head height but not behind a steel garage door. The Home 3 Pro has a wired Ethernet port, which is the robust answer for detached garages. An offline Hypervolt will still charge in plug-and-charge, so confirm whether the customer's complaint is "won't charge" or "the app shows offline"; they are different jobs.

Cable will not release from the car

A tethered cable that stays latched in the vehicle inlet is almost always the vehicle's lock, not the charger. Most cars release the latch when unlocked with the key fob or via a release in the boot or under the bonnet. Hypervolt's own guidance covers latching failures as a vehicle-side issue to try first; forcing the plug damages the inlet.

Solar matching that "doesn't work"

Super Eco needs a correctly fitted CT clamp on the meter tail reading export. A clamp fitted the wrong way round reads import as export, or vice versa; a clamp on the PV string instead of the grid tail cannot see household load. The app shows the live grid reading: with the house idle and the sun out, it should show negative (export). Also check that the car's own charge schedule is not blocking the session, and that export exceeds the 1.4 kW minimum. See ct clamp load management and ev charger solar integration.

Installation checks when the unit keeps going red

  1. Safe isolation and proving dead to GS38 before opening anything. See safe isolation procedure.
  2. Terminals: loose incoming L or N produces voltage excursions under load, and the unit trips on its voltage window. Check torque.
  3. Supply voltage under load: run a 3 kW load and watch L–N. A drop of more than 10 V suggests a high-impedance supply or poor termination.
  4. Earthing arrangement: on PME, confirm no earth rod has been fitted that bypasses the charger's PEN detection logic, and that the earthing is as the manufacturer specifies. See pme earthing ev charging.
  5. Upstream protection: 30 mA Type A RCD or RCBO (Type AC is not acceptable for a charger). Test trip time at 1× and 5× IΔn.
  6. Insulation resistance of the circuit with the charger disconnected: 1 MΩ minimum at 500 V DC, expect far higher.
  7. Record Zs and prospective fault current and compare with the commissioning certificate; see ev charger testing commissioning.

If every reading is healthy and red returns with no car connected, the fault is internal. Hypervolt's support line handles warranty; installers should not open the sealed unit.

Frequently Asked Questions

Why does my Hypervolt flash green for ten minutes before it starts charging?

Because the Electric Vehicles (Smart Charge Points) Regulations 2021 require a randomised delay of up to 600 seconds before each charging session begins, so that millions of chargers do not switch on in the same second after a tariff window opens. The user can disable the random delay in the app, but it is on by default and the flashing green is the charger counting it down.

Does a Hypervolt need an earth rod?

Not on a PME (TN-C-S) supply in the UK: the built-in voltage-monitoring open-PEN protection meets BS 7671:2018+A4:2026 Regulation 722.411.4.1 without a separate earth electrode. The installer still needs to confirm the supply type, fit a 30 mA Type A RCD or RCBO upstream and record the earthing arrangement on the certificate. A TT installation needs its own electrode as for any other circuit.

Can I just reset it when it goes red?

Once. Hypervolt's own advice is one reboot at the isolator. If red returns, the unit is telling you about a supply, vehicle or internal problem that resetting will not fix and may be masking. Repeated resets on a PEN-fault trip in particular put the user at risk of a live car body.

The app says offline but the car is charging. Is that a fault?

No. Local plug-and-charge works without the cloud. The customer loses schedules, solar matching and remote control until the connection is restored, so it is worth fixing, but it is a network job not an electrical one.

Does the Hypervolt replace the RCD on the circuit?

No. It contains 6 mA DC detection, which is what allows a Type A RCD to be used instead of a Type B, but the 30 mA AC RCD or RCBO is still required upstream. Hypervolt's technical sheet states this explicitly.

Regulations & Standards