Summary
A collapsed drain is the job that follows a blocked drain. The jetting clears, the camera goes down, and at 7.4 m from the chamber there is a fractured clay pipe with the crown gone and soil washing in. The customer wants a price. This guide is how to build one that covers the real cost of the dig, the reinstatement and the regulatory steps, and leaves a margin.
Three things decide the price before a spade goes in: who owns the pipe, how deep it is, and what is on top of it. Ownership decides whether the customer pays at all. Depth decides whether the trench needs support and a digger, or can be hand-dug by one person in a morning. Surface decides the reinstatement, which on a block-paved drive or a tiled kitchen floor can cost more than the drain repair itself. For the pricing of clearance and survey work that precedes a repair, see blocked drain clearance pricing guide and cctv drain survey pricing guide; for the alternative where excavation can be avoided, see no dig drain repair.
The common pricing mistake is quoting a collapsed drain as a plumbing job. It is a groundworks job with a plumbing component. Excavation safety, spoil, muck-away and reinstatement are the cost drivers, and an air test, a Building Control inspection and a water company build-over check may all be required before the trench is backfilled.
Key Facts
- Ownership — under the Private Sewers Transfer Regulations 2011, drains serving more than one property and any drain beyond the property boundary transferred to the water company on 1 October 2011. A drain serving only the customer's house, inside their boundary, is theirs. Check with the water company before quoting; their repair is free to the customer.
- CCTV survey first — a push-rod survey with a report to BS EN 13508-2 (MSCC5 defect codes) locates the collapse to within a metre and gives the depth from the sonde. £150–£350 domestic.
- Typical depths — a domestic foul drain runs 600–900 mm deep at the house falling to 1–1.5 m at the chamber nearest the sewer; older terraces can be 2 m plus at the rear chamber.
- Trench support — HSE guidance treats any trench where a person could be buried as needing support or battering; in practice any trench over 1.2 m deep gets trench sheets or a box, and shallower trenches in loose or wet ground get them too.
- Excavation rate — hand dig in soft ground £150–£250 per m³; mini-digger (1.5 t, £180–£260 per day hire plus delivery) in open ground around £60–£120 per m³ including operator.
- Spoil — a 1 m deep, 600 mm wide trench produces 0.6 m³ per metre, bulking to about 0.8 m³; clay spoil is 1.6–1.8 tonnes per m³. A 6-yard skip (about 4.6 m³) is £250–£400; grab lorry £250–£350 per load.
- Pipe — 110 mm PVC-U underground drainage to BS EN 1401 at £8–£15 per metre; vitrified clay to BS EN 295 at £15–£30 per metre; flexible couplings to join new plastic to old clay £15–£40 each.
- Bedding and surround — 10 mm pea shingle or single-size gravel, 100 mm bed and 100 mm surround (300 mm cover before backfill with selected fill) per Approved Document H; about 0.25 m³ per metre of trench.
- Minimum cover — Approved Document H requires 600 mm under gardens and 900 mm under drives and roads for rigid pipes without concrete protection; shallower runs need a concrete surround or a protective slab.
- Falls — 100 mm pipe at not flatter than 1:80 with a minimum flow, or 1:40 where only a WC is connected (Approved Document H Table 6 figures).
- Air test — Approved Document H: drain pressurised to 100 mm water gauge, held for 5 minutes with no more than 25 mm loss. Carried out before backfilling, with Building Control present or by agreement.
- Building Control — repair or replacement of an underground drain is notifiable under the Building Regulations 2010 (Part H). A building notice costs £200–£350; some authorities exempt like-for-like repair of a short section, so ask.
- Build-over — if the collapsed drain is a public sewer or lateral drain and any part of the repair is within 3 m of a building, the water company must be involved; see building over a sewer build over agreement.
- Reinstatement — topsoil and turf £20–£40 per m²; concrete £80–£120 per m²; block paving lift and relay £60–£100 per m² with matching blocks; tarmac patch £80–£150 per m² (always visible); internal solid floor with screed and DPM £150–£300 per m² before floor finishes.
- Inspection chamber — a new 450 mm plastic chamber with a cover to BS EN 124 costs £150–£300 in materials and half a day to set.
- Insurance — most buildings insurance policies cover accidental damage to underground drains; a leaking or collapsed drain caused by tree roots or ground movement is often claimable, so suggest the customer checks before paying.
- Labour — groundworker £180–£260 per day; two people are needed for any trench over 1 m.
- VAT — standard 20% on repairs.
Quick Reference Table
Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.
Try squote free →| Scenario | Depth | Surface | Typical price (2026) |
|---|---|---|---|
| Single collapsed section, 1 m of pipe | Up to 1 m | Lawn or soil | £1,500–£2,500 |
| Single section plus new chamber | Up to 1.2 m | Lawn or soil | £2,200–£3,500 |
| Two to three metres replaced | 1–1.5 m | Lawn or soil | £2,500–£4,500 |
| Single section | 1–1.5 m | Block paving or patio | £2,800–£5,000 |
| Single section | 1–1.5 m | Concrete or tarmac drive | £3,000–£6,000 |
| Single section | Any | Under solid house floor | £5,000–£10,000 |
| Section under the public footway or road | 1–2 m | Highway | Usually the water company's; £8,000–£15,000 if private |
| Patch liner instead of excavation | Any | Any | £500–£1,200 per patch |
| Full relining, per metre | Any | Any | £80–£150 per metre |
Detailed Guidance
Step one: establish ownership
Before pricing, draw the run. The customer's foul drain leaves the house, usually to a chamber in the back or side garden, and then either runs to a chamber at the front and out to the sewer in the road, or runs along the back of the terrace collecting neighbours' drains on the way. Under the 2011 transfer, the moment a drain takes a second property's flow it becomes a public sewer, and the length from the boundary to the public sewer became a lateral drain owned by the water company, even where it crosses the customer's land.
If the collapse is in a shared run or beyond the boundary, the water company repairs it at no cost to the customer. Tell the customer, give them the CCTV report and the location, and charge for the survey only. Quoting to repair a public sewer is both a wasted quote and, if the work goes ahead, a problem: unauthorised work on a public sewer can leave the contractor liable.
Where the drain is private and under a shared access or a neighbour's garden, access rights need agreeing in writing before the price is accepted.
Step two: survey and locate
A CCTV survey with a sonde on the camera head gives the position and depth of the defect; mark it on the surface. Note what else the camera shows: a single fracture in otherwise sound clay is a short dig; a run with displaced joints, root ingress and multiple fractures should be priced as a longer replacement or a full reline, because a 1 m repair in a failing run brings the customer back in a year. Grade the pipe condition in the quote and price the alternatives.
Check the depth against the reinstatement: a collapse at 1.2 m under a block-paved drive means lifting the blocks over a 1 m wide strip, 600 mm of sub-base to be removed and re-laid, and a compaction plant hire. The pipe is a small part of that price.
Step three: build the excavation price
Work the trench volume: length of pipe to be exposed (the collapsed section plus 500 mm each side to get sound pipe for the couplings) by depth by width (600 mm minimum for a person to work; 900 mm for a trench box). Price the dig by the method:
- Hand dig in soft ground to 1 m: a groundworker shifts about 2–3 m³ a day; £150–£250 per m³.
- Mini-digger in open ground: hire £180–£260 per day plus £80–£120 delivery and collection; an operator moves 10–20 m³ a day in a confined domestic trench; price around £60–£120 per m³.
- Breaking out concrete or tarmac first: a breaker hire at £60–£90 per day and half a day's labour per 5 m².
Add trench support where the depth or the ground calls for it: trench sheets and props hired at £80–£150 per week for a short run; a trench box at £150–£300 per week plus transport. Add spoil: the bulked volume minus what will go back as backfill (the pipe surround volume and the new sub-base come out of the backfill, so most of the spoil leaves site). One 6-yard skip per 4 m³ of bulked spoil at £250–£400, or a grab lorry.
A worked example for a 1 m collapse at 1.1 m depth under a lawn: trench 2 m long, 1.1 m deep, 0.6 m wide = 1.3 m³, bulked 1.7 m³. Hand dig two people half a day (£240). Pipe and couplings 2 m of 110 mm PVC-U plus two flexible couplings (£90). Pea shingle 0.5 m³ (£60). Backfill selected and compacted, surplus spoil in a bag or shared skip (£120). Air test and Building Control notice (£250). Turf and topsoil reinstatement 2 m² (£80). Labour second half day for pipe, test, backfill and reinstatement (£240). Direct cost about £1,080; with 25% margin and the £200 survey already charged, the repair quote is £1,350–£1,500. That is the bottom of the table above, and the figure rises quickly with depth and surface.
Step four: materials and the pipe work
Expose the pipe to sound material each side of the collapse, cut the clay square with a disc cutter, and remove the damaged section. Lay a 100 mm bed of pea shingle, set the new PVC-U or clay pipe to the existing fall, and join to the old pipe each end with flexible couplings (the type with a stainless band and an EPDM sleeve rated for the pipe materials being joined). Where a joint falls at the collapse, or a branch connects there, replace with a new fitting rather than coupling onto a damaged socket.
Surround the pipe with 100 mm of shingle to the sides and over the crown, then selected backfill in 150 mm layers, compacted, to 300 mm cover before any mechanical compaction. Under drives and roads the minimum cover is 900 mm for an unprotected rigid pipe; for shallower runs lay a concrete surround or a reinforced slab over a compressible layer. Do not backfill until the air test has been witnessed or agreed.
If a chamber is needed (a change of direction, a junction, or a run over 45 m without access), set a 450 mm plastic chamber base in concrete, build the risers to level, and finish with a cover and frame to BS EN 124 rated for the location: class A15 for a garden, B125 for a driveway, D400 for a road.
Step five: test, inspect, reinstate
Plug the run and air test to Approved Document H: 100 mm water gauge, 5 minutes, no more than 25 mm loss. Where Building Control is involved, book the inspection with the trench open; a photograph with a tape in it is accepted by some authorities for a like-for-like repair. Backfill, compact and reinstate the surface. Price reinstatement at the rates in Key Facts, and tell the customer in the quote that a tarmac patch will not match and that block paving relaid with the same blocks will show the line for a season.
Alternatives to excavation
Where the camera shows a fracture or a displaced joint but the pipe has not actually collapsed (the bore is still mostly open), a patch liner at £500–£1,200 per patch, or a full cured-in-place liner at £80–£150 per metre, avoids the dig and the reinstatement. Liners cannot be used through a true collapse because the liner needs a bore to be inverted through; a short dig to replace the collapsed section, followed by a liner through the rest of the failing run, is a common combination. Price both options where the survey allows and let the customer choose.
Margin and risk
A collapsed drain repair carries three risks the quote should cover: the collapse is longer than the camera showed (the camera stops at the collapse and cannot see beyond it), the ground is wet and the trench needs pumping and support, and services (gas, water, electric) are found in the trench. Put a measured rate in the quote for additional metres of pipe and additional excavation (per metre and per m³), state that trench support and pumping will be charged if needed with the day rates given, and insist on service plans or a CAT scan before digging. On the base price, a 20–30% margin on direct cost is standard for groundworks; the reinstatement element is where the price is most often underestimated.
Frequently Asked Questions
Is a collapsed drain the water company's responsibility?
Often. If the drain serves more than one property at the point of collapse, or the collapse is beyond the property boundary, it is a public sewer or a lateral drain and the water company repairs it free of charge under the 2011 transfer. If it serves only the customer's house and is inside their boundary, it is private and the customer pays. The water company's own sewer map, and a telephone call to its operations team with the CCTV report, settles it.
Does a drain repair need Building Regulations approval?
Replacing or altering an underground drain is controlled work under Part H of the Building Regulations 2010, so the local authority should be notified. In practice many authorities accept a like-for-like repair of a short section without a formal notice, while a new run, a new chamber or a change of route needs a building notice and an inspection. Ask the authority; a building notice is £200–£350 and takes the question away.
Will the customer's insurance pay?
Many buildings insurance policies include accidental damage to underground services, and some add a specific "drains" extension. Damage from tree roots, ground movement or vehicle loading is commonly claimed; wear and tear and lack of maintenance are commonly excluded. The CCTV report is the evidence the insurer wants. Tell the customer to check their policy before accepting the quote, and expect the insurer to ask for two quotes.
How deep can a drain be dug by hand safely?
HSE guidance does not set a single depth; it says a trench must be supported or battered wherever there is a risk of collapse, and that nobody should work in an unsupported trench where they could be buried. In practice anything over 1.2 m deep gets sheets or a box, and shallower trenches in sand, fill or wet clay get them too. A person standing in a 1 m trench is up to their waist; a side collapse at that depth can still trap and crush. Two people on site, one out of the trench, is the minimum.
Regulations & Standards
Building Regulations 2010, Part H (Approved Document H) — foul water drainage: bedding, cover, falls, access and testing
Private Sewers Transfer Regulations 2011 — transfer of shared drains and lateral drains to the water and sewerage companies
Water Industry Act 1991 — sewer ownership and connection
BS EN 752 — Drain and sewer systems outside buildings
BS EN 1610 — Construction and testing of drains and sewers
BS EN 1401 — PVC-U underground drainage pipes and fittings
BS EN 295 — Vitrified clay pipe systems for drains and sewers
BS EN 124 — Gully tops and manhole tops for vehicular and pedestrian areas; load classes
BS EN 13508-2 — Investigation and assessment of drain and sewer systems; visual inspection coding (MSCC5)
CDM Regulations 2015 — excavation as construction work; method statement and competent supervision
HSE Construction Information Sheet CIS8 — Safety in excavations
Approved Document H: Drainage and waste disposal — bedding, cover, falls and air testing
Water UK — sewer and drain responsibility — who owns which pipe after the 2011 transfer
HSE — excavations — trench support and safe working
Ofwat — private sewer transfer — regulatory background to the 2011 transfer
Planning Portal — drainage and Building Regulations — when notification is required
blocked drain clearance pricing guide — clearance and survey pricing before a repair is diagnosed
cctv drain survey pricing guide — survey pricing and reporting to BS EN 13508-2
no dig drain repair — patch lining and relining as an alternative to excavation
part h drainage — Part H requirements in full
excavation safety trench support — trench sheets, boxes and safe digging
building over a sewer build over agreement — when the water company must be involved