Summary

An electric shower leaking from its casing is a job that gets refused by plumbers as "electrical" and by electricians as "plumbing", which is why so many are simply replaced. In fact most of them are a fifteen-minute repair with a part that costs less than a coffee, provided the fault is diagnosed before the cover comes off and the cause of the fault is dealt with as well as the symptom. The two components that account for most leaks, the pressure relief device and the inlet solenoid, are user-serviceable on nearly every current unit and are stocked by any plumbers' merchant that carries the brand.

The pressure relief device is a deliberate weak point. An electric shower heats water in a small can with one or two 3–4 kW elements; if the outlet is restricted while the elements are on, pressure in the can rises quickly and the PRD, a plastic plug, a spring valve or on some units a burst disc, releases before the can splits. Water then pours from the bottom of the casing, usually while the shower is running, and the customer reports "the shower is leaking". The actual fault is nearly always a blocked shower head, a kinked or crushed hose, or a hose and head with a flow restrictor fitted that the unit was not designed for. Replacing the PRD alone fixes the symptom until the next shower.

This guide gives a diagnosis sequence that separates the PRD, the solenoid, the heater can and the hose, the safe way to isolate and open the unit, the repair for each, and the point at which a new shower is the better answer. For a shower that will not run at all see electric shower not working; for one that trips the board see electric shower tripping rcd; for weak flow see electric shower low pressure; for the installation and circuit requirements see electric shower installation.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Symptom When it leaks Most likely component Fix
Water pours from base while running, flow from head weak Shower on PRD blown, caused by blocked head or hose Descale/replace head, check hose, new PRD, clean filter
Water from base while running, head flows normally Shower on Solenoid body seal or diaphragm; inlet elbow washer Replace solenoid or O-ring; reseat inlet connection
Drip from head when shower off Shower off Solenoid passing (diaphragm or seat) Replace solenoid valve
Drip from base when shower off, head dry Shower off Water held in can by passing solenoid; or can weeping Replace solenoid; if still weeping, can is split
Leak from hose nut or elbow at bottom of unit Shower on Hose washer/O-ring, loose nut, hose pulled off New washer, tighten by hand, refit hose
Leak only after cold weather First use after frost Split can or inlet elbow Replace can/elbow or unit; insulate pipework
Leak from back of unit, wall wet Any Inlet compression or push-fit joint behind unit Remake joint
PRD blows repeatedly after replacement Shower on Restriction not cleared; wrong head; mains pressure too high Approved head; check pressure, PRD type
TCO trips and small leak Shower on Low flow overheating water; scale in can Clear restriction; descale or replace can
Water inside casing but no obvious source Shower on Hairline crack in can or solenoid body; condensation on cold inlet Dry, run, trace with paper towel

Detailed Guidance

Diagnosis: before you take the cover off

ELECTRIC SHOWER LEAKING — DIAGNOSIS
│
├─ 1. Is the leak from the HOSE NUT or OUTLET ELBOW rather than the casing?
│      → Hand-tighten, new washer, refit hose. Done.
│
├─ 2. Unscrew the shower head. Run the shower on cold with the bare hose.
│      ├─ Flow strong, leak stops → head was blocked; PRD has blown.
│      │     → Descale/replace head. Isolate, open, new PRD, clean filter.
│      └─ Flow still weak → restriction upstream (hose, filter, solenoid)
│            or low mains pressure. Check hose for kinks; check filter.
│
├─ 3. Does it leak with the shower OFF?
│      ├─ Drip from the head → solenoid passing. Replace solenoid.
│      └─ Drip from the base → passing solenoid filling the can, or split can.
│            → Replace solenoid first; if it still weeps, the can is gone.
│
├─ 4. Leaks while running with head flowing normally?
│      → Isolate, prove dead, open. Dry everything. Run for 60 s and look:
│         solenoid body, diaphragm cover, inlet elbow, can seams, element flange.
│
└─ 5. First leak after a frost, or unit on an external/unheated wall?
       → Expect a split can or elbow. Quote for replacement and insulation.

Always start with the head. It takes thirty seconds and it is the cause of most PRD leaks. A head that has not been descaled in two years in a hard-water area is passing a fraction of its design flow; the PRD blows, the customer replaces the head with a cheap one with a restrictor, and the PRD blows again. Soak the head in a descaler or replace it with the manufacturer's approved head.

Safe isolation

Electric showers are the single highest-rated appliance in most houses, and the terminal block inside is live at 230 V whenever the pull-cord is on. Before the cover comes off:

  1. Switch the shower off at its own control and at the pull-cord or wall isolator (the neon should go out).
  2. Identify the shower MCB or RCBO at the consumer unit, switch it off and lock it off, or at minimum tell everyone in the house not to touch the board.
  3. Prove the two-pole tester on a known live source, test between L–N, L–E and N–E at the shower terminal block once the cover is off, then prove the tester again (GS38 practice).
  4. Turn off the water: many showers have an isolating valve on the inlet pipework; if not, the stopcock.

Do not rely on the shower's own on/off control as isolation; it switches the elements through a microswitch or electronics, not the supply.

Replacing the PRD

The PRD is on the heater can, often at the top or on the side facing the cover, sometimes under a small clip or a screw-in plastic housing. The blown device is obvious: the plug has popped out, a spring and seal are loose in the casing, or the burst disc is holed. Note the exact part number from the model label inside the casing; PRDs are model-specific and a wrong one either leaks or fails to vent. Fit the new one dry (no PTFE or sealant on push-fit types), check the inlet filter and clean it, refit the cover, restore the water, check for leaks with the power still off by running the shower on cold where the model allows, then restore the power and run the shower through its temperature range watching for drips.

If the PRD blows again with a new approved head fitted and the hose clear, check the static mains pressure with a gauge on an outside tap. Above 10 bar static (or whatever the unit rating is) a pressure-reducing valve is needed on the supply; this is common in new developments and at the bottom of hills. Also check that the inlet filter is not partially blocked, and that the hose has not been swapped for a narrow-bore or "water-saving" type.

Never replace a PRD with a bolt, a screw or a blanked fitting. Without the relief, a blocked head over-pressurises the can until it splits, and a can splitting on a 10 kW shower has scalded people.

Solenoid valve leaks

The inlet solenoid is a coil on a brass or plastic valve body at the inlet side of the unit. It leaks from its body-to-manifold seal (an O-ring that has hardened), from the diaphragm cover screws, or by passing when the diaphragm is scaled or torn. A passing solenoid shows as a drip from the head when the shower is off, and because it lets the can slowly fill and pressurise, can also push a weep past a tired PRD.

Replacement is a matter of isolating, removing the coil's electrical connector (note the orientation), undoing the valve body (usually two or four screws, or a bayonet), and fitting the new valve with new seals. Clean out the inlet filter at the same time; grit in the filter is often what tore the diaphragm. Check the coil resistance of the old unit if the leak coincided with the shower not starting; a dead coil and a leaking valve body is one fault, not two.

Heater can and element leaks

A heater can weeps at a seam, at the element flange gasket or through a scale-corrosion pinhole. Dry the can with a cloth, run the shower for a minute and look for the wet line. A can that has been frozen often shows a bulge or a split along the moulding line. The element flange gasket can be replaced on some models; a split or pinholed can means a new can, which on most units costs £60–£120 as a part plus an hour's labour. Set against a new shower at £90–£200 with a two-year warranty, replacement is usually the better value unless the unit is high-end or the installation (tiles, cable route) makes a like-for-like swap difficult.

Hoses, heads and the Water Regulations

The hose and head are part of the appliance for approval purposes and part of the water installation for the Water Supply (Water Fittings) Regulations 1999. The manufacturer's hose is sized for the unit's flow; a thinner aftermarket hose can trigger the PRD or the TCO. A hose long enough to drop the head into a bath or a filled tray creates a Fluid Category 3 backflow risk and needs either a double check valve on the shower inlet or a retaining ring on the riser rail that keeps the head above the spill-over level. Most electric showers have an integral backflow protection on the inlet, but check the installation instructions rather than assume.

When to replace the unit

Replace rather than repair when the can is split or heavily scaled, when the unit is more than about 10–12 years old and a second component has failed, when the PCB or thermistor has also faulted, when parts are no longer available, or when the customer wants a higher kW rating (which may also mean a cable and MCB upgrade; see electric shower installation). Like-for-like replacement on the existing cable, isolator and supply is a straightforward swap provided the cable is adequate for the new rating: 8.5 kW on 6 mm² is marginal and depends on the installation method; 9.5–10.5 kW generally wants 10 mm² and a 45–50 A device. Check the existing cable size and route with the cover off and quote the upgrade if needed rather than fitting a bigger shower on a cable that will overheat.

Frequently Asked Questions

The shower leaks from the bottom and the water is weak. Is the unit finished?

Almost certainly not. Weak flow and a leak from the base together is the classic blown PRD caused by a blocked head. Take the head off and run the hose bare; if the flow is strong, descale or replace the head, replace the PRD and clean the inlet filter. The unit will probably last years more. Only if the flow is still weak with the head off and the filter clean, or the leak continues after the PRD is replaced, is there a bigger fault.

Can I use any shower head on an electric shower?

Use the manufacturer's head or one they approve. Electric showers heat a small flow, so the head and hose bore are matched to the kW rating; a head with a flow regulator or a very fine spray pattern can restrict flow enough to trip the thermal cut-out or blow the PRD, and the warranty is usually void with an unapproved head. "Water-saving" heads designed for mixer showers are the usual cause of repeated PRD failures on electric units.

Do I need an electrician to replace the PRD or solenoid?

The repair is mechanical, but the unit must be electrically isolated and proved dead before the cover is removed, and the terminals inside carry 230 V at up to 45 A. A plumber or bathroom fitter who is competent to isolate and prove dead with a GS38 two-pole tester can do the work; a repair that involves the terminal block, the cable or the isolator is electrical work and should be done by someone competent under BS 7671. Any work that creates a new circuit is notifiable under Part P in England.

Why does the shower drip from the head long after it has been turned off?

The inlet solenoid is passing: its diaphragm is scaled, torn or not seating, so mains water keeps trickling through the can and out of the head. It is a nuisance rather than a danger, but it wastes water, deposits scale in the can and can gradually pressurise the can against the PRD. Replace the solenoid valve and clean the inlet filter.

The leak only started after a cold snap. What has happened?

Water in the heater can or the inlet elbow has frozen and split the plastic. It is common where the shower is on an external wall of a poorly heated bathroom, in an annexe or outbuilding, or where the supply pipe runs through an unheated roof space. The can or the elbow is replaced or the unit is swapped, and the supply pipework insulated or, in an outbuilding, protected with trace heating or drained down in winter. See pipe lagging for insulation thickness.