Summary
An electric shower leaking from its casing is a job that gets refused by plumbers as "electrical" and by electricians as "plumbing", which is why so many are simply replaced. In fact most of them are a fifteen-minute repair with a part that costs less than a coffee, provided the fault is diagnosed before the cover comes off and the cause of the fault is dealt with as well as the symptom. The two components that account for most leaks, the pressure relief device and the inlet solenoid, are user-serviceable on nearly every current unit and are stocked by any plumbers' merchant that carries the brand.
The pressure relief device is a deliberate weak point. An electric shower heats water in a small can with one or two 3–4 kW elements; if the outlet is restricted while the elements are on, pressure in the can rises quickly and the PRD, a plastic plug, a spring valve or on some units a burst disc, releases before the can splits. Water then pours from the bottom of the casing, usually while the shower is running, and the customer reports "the shower is leaking". The actual fault is nearly always a blocked shower head, a kinked or crushed hose, or a hose and head with a flow restrictor fitted that the unit was not designed for. Replacing the PRD alone fixes the symptom until the next shower.
This guide gives a diagnosis sequence that separates the PRD, the solenoid, the heater can and the hose, the safe way to isolate and open the unit, the repair for each, and the point at which a new shower is the better answer. For a shower that will not run at all see electric shower not working; for one that trips the board see electric shower tripping rcd; for weak flow see electric shower low pressure; for the installation and circuit requirements see electric shower installation.
Key Facts
- PRD (pressure relief device) — on the heater can, usually a small plastic plug with a spring and seal, or a push-in blow-out plug; it vents when can pressure exceeds roughly 10–15 bar (model-specific). A PRD that has blown has done its job; find the restriction before replacing it.
- The restriction — a limescaled head is the usual culprit; a 10.5 kW shower needs around 10–12 l/min through the head at full temperature and a head that is half-scaled cannot pass it. Other causes: a kinked or collapsed hose, a hose with an internal flow regulator, a head with an "eco" restrictor, or a non-approved head.
- Inlet solenoid valve — the electrically operated valve that opens when the shower is switched on. It leaks in two ways: from its body seal or diaphragm when the shower is running, or by "passing" (dripping from the head when the shower is off). A passing solenoid can also leave water in the heater can and show as a drip from the unit base.
- Inlet filter — a fine mesh filter at the inlet connection or in the solenoid body; grit and scale in it reduce flow and raise the chance of the PRD blowing. Clean it at every repair.
- Heater can — the tank with the elements; it splits from frost, from repeated over-pressure with a failed PRD that someone has replaced with a bolt, or from scale corrosion. A split can is a new can or a new shower.
- Hose connection — the outlet elbow at the bottom of the unit takes the hose with a washer or O-ring; a leak at the hose nut or a hose pulled off the elbow is the easiest fix and often misreported as "leaking from the unit".
- Electrical isolation — a 45 A or 50 A double-pole ceiling pull-cord or wall switch outside Zones 0–2 is the local isolator; isolate, prove dead with a two-pole tester to GS38, and lock off at the consumer unit if anyone else is in the house. The terminals inside carry 230 V at up to 45 A.
- Circuit — a 9.5–10.5 kW shower is typically on a dedicated 45 A or 50 A radial in 10 mm² cable with 30 mA RCD protection under BS 7671:2018+A4:2026 Regulation 701.411.3.3; check the installation when the cover is off, since a scorched terminal or undersized cable is a common finding.
- Water supply — mains cold only, minimum maintained pressure around 1.0 bar at 8 l/min for most units (check the model), maximum 10 bar static; a pressure-reducing valve is needed where mains pressure exceeds the unit rating, and high mains pressure stresses the PRD and seals.
- Water Regulations — the shower hose and head are fittings under the Water Supply (Water Fittings) Regulations 1999; a flexible hose that can reach into the tray or bath water needs a double check valve or a hose-retaining ring to prevent backflow (Fluid Category 3).
- Product standard — electric showers are instantaneous water heaters tested to BS EN 60335-2-35 and must carry UKCA or CE marking; replacement parts should be the manufacturer's.
- Approved heads — manufacturers specify the head and hose; a head with a smaller bore or a flow restrictor can trigger the PRD or the over-temperature thermal cut-out (TCO) repeatedly.
- TCO — a thermal cut-out on the heater can that trips if the water overheats; low flow from a restriction can trip it before the PRD blows. Many are resettable by a button on the can.
- Frost — a shower unit on an uninsulated external wall or in an unheated outbuilding can freeze; a leak that appears in the first thaw of winter from a split can or inlet elbow is frost damage, and the fix includes insulating or moving the pipework.
- Part P — replacing a shower unit like for like on the existing circuit is not notifiable in England; a new circuit, a consumer-unit change or work in a bathroom that involves a new circuit is notifiable. In Wales, work in a bathroom is more widely notifiable.
- Cost — PRD replacement and head descale: 30–45 minutes, £60–£110; solenoid valve replacement: 45–60 minutes, £90–£160 (part £25–£60); new heater can: £60–£120 part, often making replacement the better value; like-for-like shower replacement on the existing supply and circuit: 1–1.5 hours, £180–£320 plus the unit (£90–£300).
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Symptom | When it leaks | Most likely component | Fix |
|---|---|---|---|
| Water pours from base while running, flow from head weak | Shower on | PRD blown, caused by blocked head or hose | Descale/replace head, check hose, new PRD, clean filter |
| Water from base while running, head flows normally | Shower on | Solenoid body seal or diaphragm; inlet elbow washer | Replace solenoid or O-ring; reseat inlet connection |
| Drip from head when shower off | Shower off | Solenoid passing (diaphragm or seat) | Replace solenoid valve |
| Drip from base when shower off, head dry | Shower off | Water held in can by passing solenoid; or can weeping | Replace solenoid; if still weeping, can is split |
| Leak from hose nut or elbow at bottom of unit | Shower on | Hose washer/O-ring, loose nut, hose pulled off | New washer, tighten by hand, refit hose |
| Leak only after cold weather | First use after frost | Split can or inlet elbow | Replace can/elbow or unit; insulate pipework |
| Leak from back of unit, wall wet | Any | Inlet compression or push-fit joint behind unit | Remake joint |
| PRD blows repeatedly after replacement | Shower on | Restriction not cleared; wrong head; mains pressure too high | Approved head; check pressure, PRD type |
| TCO trips and small leak | Shower on | Low flow overheating water; scale in can | Clear restriction; descale or replace can |
| Water inside casing but no obvious source | Shower on | Hairline crack in can or solenoid body; condensation on cold inlet | Dry, run, trace with paper towel |
Detailed Guidance
Diagnosis: before you take the cover off
ELECTRIC SHOWER LEAKING — DIAGNOSIS
│
├─ 1. Is the leak from the HOSE NUT or OUTLET ELBOW rather than the casing?
│ → Hand-tighten, new washer, refit hose. Done.
│
├─ 2. Unscrew the shower head. Run the shower on cold with the bare hose.
│ ├─ Flow strong, leak stops → head was blocked; PRD has blown.
│ │ → Descale/replace head. Isolate, open, new PRD, clean filter.
│ └─ Flow still weak → restriction upstream (hose, filter, solenoid)
│ or low mains pressure. Check hose for kinks; check filter.
│
├─ 3. Does it leak with the shower OFF?
│ ├─ Drip from the head → solenoid passing. Replace solenoid.
│ └─ Drip from the base → passing solenoid filling the can, or split can.
│ → Replace solenoid first; if it still weeps, the can is gone.
│
├─ 4. Leaks while running with head flowing normally?
│ → Isolate, prove dead, open. Dry everything. Run for 60 s and look:
│ solenoid body, diaphragm cover, inlet elbow, can seams, element flange.
│
└─ 5. First leak after a frost, or unit on an external/unheated wall?
→ Expect a split can or elbow. Quote for replacement and insulation.
Always start with the head. It takes thirty seconds and it is the cause of most PRD leaks. A head that has not been descaled in two years in a hard-water area is passing a fraction of its design flow; the PRD blows, the customer replaces the head with a cheap one with a restrictor, and the PRD blows again. Soak the head in a descaler or replace it with the manufacturer's approved head.
Safe isolation
Electric showers are the single highest-rated appliance in most houses, and the terminal block inside is live at 230 V whenever the pull-cord is on. Before the cover comes off:
- Switch the shower off at its own control and at the pull-cord or wall isolator (the neon should go out).
- Identify the shower MCB or RCBO at the consumer unit, switch it off and lock it off, or at minimum tell everyone in the house not to touch the board.
- Prove the two-pole tester on a known live source, test between L–N, L–E and N–E at the shower terminal block once the cover is off, then prove the tester again (GS38 practice).
- Turn off the water: many showers have an isolating valve on the inlet pipework; if not, the stopcock.
Do not rely on the shower's own on/off control as isolation; it switches the elements through a microswitch or electronics, not the supply.
Replacing the PRD
The PRD is on the heater can, often at the top or on the side facing the cover, sometimes under a small clip or a screw-in plastic housing. The blown device is obvious: the plug has popped out, a spring and seal are loose in the casing, or the burst disc is holed. Note the exact part number from the model label inside the casing; PRDs are model-specific and a wrong one either leaks or fails to vent. Fit the new one dry (no PTFE or sealant on push-fit types), check the inlet filter and clean it, refit the cover, restore the water, check for leaks with the power still off by running the shower on cold where the model allows, then restore the power and run the shower through its temperature range watching for drips.
If the PRD blows again with a new approved head fitted and the hose clear, check the static mains pressure with a gauge on an outside tap. Above 10 bar static (or whatever the unit rating is) a pressure-reducing valve is needed on the supply; this is common in new developments and at the bottom of hills. Also check that the inlet filter is not partially blocked, and that the hose has not been swapped for a narrow-bore or "water-saving" type.
Never replace a PRD with a bolt, a screw or a blanked fitting. Without the relief, a blocked head over-pressurises the can until it splits, and a can splitting on a 10 kW shower has scalded people.
Solenoid valve leaks
The inlet solenoid is a coil on a brass or plastic valve body at the inlet side of the unit. It leaks from its body-to-manifold seal (an O-ring that has hardened), from the diaphragm cover screws, or by passing when the diaphragm is scaled or torn. A passing solenoid shows as a drip from the head when the shower is off, and because it lets the can slowly fill and pressurise, can also push a weep past a tired PRD.
Replacement is a matter of isolating, removing the coil's electrical connector (note the orientation), undoing the valve body (usually two or four screws, or a bayonet), and fitting the new valve with new seals. Clean out the inlet filter at the same time; grit in the filter is often what tore the diaphragm. Check the coil resistance of the old unit if the leak coincided with the shower not starting; a dead coil and a leaking valve body is one fault, not two.
Heater can and element leaks
A heater can weeps at a seam, at the element flange gasket or through a scale-corrosion pinhole. Dry the can with a cloth, run the shower for a minute and look for the wet line. A can that has been frozen often shows a bulge or a split along the moulding line. The element flange gasket can be replaced on some models; a split or pinholed can means a new can, which on most units costs £60–£120 as a part plus an hour's labour. Set against a new shower at £90–£200 with a two-year warranty, replacement is usually the better value unless the unit is high-end or the installation (tiles, cable route) makes a like-for-like swap difficult.
Hoses, heads and the Water Regulations
The hose and head are part of the appliance for approval purposes and part of the water installation for the Water Supply (Water Fittings) Regulations 1999. The manufacturer's hose is sized for the unit's flow; a thinner aftermarket hose can trigger the PRD or the TCO. A hose long enough to drop the head into a bath or a filled tray creates a Fluid Category 3 backflow risk and needs either a double check valve on the shower inlet or a retaining ring on the riser rail that keeps the head above the spill-over level. Most electric showers have an integral backflow protection on the inlet, but check the installation instructions rather than assume.
When to replace the unit
Replace rather than repair when the can is split or heavily scaled, when the unit is more than about 10–12 years old and a second component has failed, when the PCB or thermistor has also faulted, when parts are no longer available, or when the customer wants a higher kW rating (which may also mean a cable and MCB upgrade; see electric shower installation). Like-for-like replacement on the existing cable, isolator and supply is a straightforward swap provided the cable is adequate for the new rating: 8.5 kW on 6 mm² is marginal and depends on the installation method; 9.5–10.5 kW generally wants 10 mm² and a 45–50 A device. Check the existing cable size and route with the cover off and quote the upgrade if needed rather than fitting a bigger shower on a cable that will overheat.
Frequently Asked Questions
The shower leaks from the bottom and the water is weak. Is the unit finished?
Almost certainly not. Weak flow and a leak from the base together is the classic blown PRD caused by a blocked head. Take the head off and run the hose bare; if the flow is strong, descale or replace the head, replace the PRD and clean the inlet filter. The unit will probably last years more. Only if the flow is still weak with the head off and the filter clean, or the leak continues after the PRD is replaced, is there a bigger fault.
Can I use any shower head on an electric shower?
Use the manufacturer's head or one they approve. Electric showers heat a small flow, so the head and hose bore are matched to the kW rating; a head with a flow regulator or a very fine spray pattern can restrict flow enough to trip the thermal cut-out or blow the PRD, and the warranty is usually void with an unapproved head. "Water-saving" heads designed for mixer showers are the usual cause of repeated PRD failures on electric units.
Do I need an electrician to replace the PRD or solenoid?
The repair is mechanical, but the unit must be electrically isolated and proved dead before the cover is removed, and the terminals inside carry 230 V at up to 45 A. A plumber or bathroom fitter who is competent to isolate and prove dead with a GS38 two-pole tester can do the work; a repair that involves the terminal block, the cable or the isolator is electrical work and should be done by someone competent under BS 7671. Any work that creates a new circuit is notifiable under Part P in England.
Why does the shower drip from the head long after it has been turned off?
The inlet solenoid is passing: its diaphragm is scaled, torn or not seating, so mains water keeps trickling through the can and out of the head. It is a nuisance rather than a danger, but it wastes water, deposits scale in the can and can gradually pressurise the can against the PRD. Replace the solenoid valve and clean the inlet filter.
The leak only started after a cold snap. What has happened?
Water in the heater can or the inlet elbow has frozen and split the plastic. It is common where the shower is on an external wall of a poorly heated bathroom, in an annexe or outbuilding, or where the supply pipe runs through an unheated roof space. The can or the elbow is replaced or the unit is swapped, and the supply pipework insulated or, in an outbuilding, protected with trace heating or drained down in winter. See pipe lagging for insulation thickness.
Regulations & Standards
BS 7671:2018+A4:2026 — Requirements for Electrical Installations (IET Wiring Regulations), Section 701 (locations containing a bath or shower): 30 mA RCD protection for all circuits, zones, isolation and switching.
BS 7671:2018+A4:2026, Chapter 46 and Section 537 — isolation and switching; the requirement for a means of isolation for the shower circuit.
Building Regulations 2010, Approved Document P (2013 edition) — electrical safety in dwellings; notifiable work including new circuits.
BS EN 60335-2-35:2016+A1:2019 — Household and similar electrical appliances: particular requirements for instantaneous water heaters.
BS EN 60335-1:2012+A15:2021 — Household and similar electrical appliances: safety, general requirements.
Water Supply (Water Fittings) Regulations 1999 — backflow protection for shower hoses (Fluid Category 3), approved fittings.
HSE Guidance Note GS38 (4th edition, 2015) — electrical test equipment for use on low-voltage electrical systems.
Electricity at Work Regulations 1989 — Regulation 13, working dead; Regulation 14, working on or near live conductors.
IET Guidance Note 7: Special Locations (6th edition) — bathroom zones and equipment selection.
Approved Document P: Electrical safety in dwellings — GOV.UK — notifiable electrical work.
HSE — GS38 Electrical test equipment for use on low voltage electrical systems — proving dead safely.
WRAS — Water Regulations Advisory Scheme: backflow prevention guidance — shower hose backflow requirements.
Triton Showers — technical support and spare parts — PRD and solenoid identification by model.
Mira Showers — electric shower troubleshooting — manufacturer fault guidance and approved accessories.
IET — Wiring Regulations BS 7671 — current edition and amendment status.
electric shower not working — solenoid, element and TCO faults when the shower will not run.
electric shower tripping rcd — earth leakage from a wet element or terminal block.
electric shower low pressure — weak flow from supply pressure, filters and heads.
electric shower installation — cable sizing, isolation and circuit requirements for new and replacement units.
shower leaking through ceiling — when the water from a leaking unit reaches the room below.
bathroom zones and ip ratings — where the unit and its isolator may be sited.