Summary

"The shower's lost its pressure" is one of the top five bathroom call-outs and one of the most misquoted. The customer feels less water on their shoulders and reaches for the word pressure; the engineer needs to think in litres per minute, because an electric shower's output is set by two things — how much cold water the mains will push through it, and how much of that water the heating element can warm to shower temperature. Either one can fall, and the fixes are completely different. Replacing a shower unit to cure a part-closed stopcock is a £250 mistake; cleaning an inlet filter to cure a scaled heater can is a wasted visit.

The second confusion is seasonal. An instantaneous electric shower heats water as it passes through, so the flow it can deliver at a given temperature depends on how cold the incoming water is. Mains water in the UK is around 15–18°C in late summer and 5–8°C in January. At 8.5 kW the same shower that gave a decent 5 litres a minute in August gives barely 4 in January, and the thermostatic or flow control automatically throttles the water to hold the temperature. Customers describe this as "the pressure has dropped"; it is the shower doing its job. The remedy, if they want more, is more kilowatts, which brings in the electrician and the cable-size question.

This guide gives a measure-first diagnosis — flow at the hose outlet, flow with the head off, flow at a nearby cold tap, dynamic pressure at the inlet — a decision tree that separates showerhead, unit, supply pipework and mains, and the fixes for each including when the answer is a higher-rated unit or mains boosting. For a shower that has stopped altogether see electric shower not working; for a shower that runs hot then cold see shower runs cold.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Measurement How to take it Healthy result Points to
Flow at shower head, shower running on cold Jug and stopwatch, 30 seconds × 2 ≥ 6 l/min cold on an 8.5 kW; manufacturer's figure Below this → continue down the table
Flow with head removed, hose only Same, head unscrewed Noticeably higher than with head Head scaled or flow regulator blocked
Flow at nearest cold tap (bath or basin) Jug and stopwatch ≥ 10–12 l/min typical mains Low here too → supply/mains, not the shower
Flow at kitchen cold tap (first draw off rising main) Jug and stopwatch ≥ 12–15 l/min typical Low here → stopcock, mains, or PRV
Dynamic pressure at shower inlet Gauge on a tee or at the nearest cold outlet while shower runs ≥ 1.0 bar maintained (or MI figure) Below → supply pipework or mains
Static pressure at outside tap or washing machine valve Gauge, nothing running 2–5 bar typical; below 1 bar is a water company issue Mains supply
Flow drop when toilet refills or tap runs Run shower, flush WC Minor drop only Large drop → shared or undersized supply
Temperature at full flow in winter Thermometer in spray 38–40°C at the manufacturer's rated flow Hot only at a trickle → scaled heater can, or rating too low for winter

Detailed Guidance

Step 1: Measure the flow, then take the head off

Run the shower on its coldest setting (so the thermostatic control is not throttling for temperature) into a measuring jug for 30 seconds and double the figure. Note it. Now unscrew the head and repeat with the bare hose. If the flow with the head off is markedly higher — say 7 l/min against 4 — the head is the problem. Soak it in a proprietary descaler or a 50/50 white vinegar solution for an hour, pick the holes out with a pin, flush, and check the small rubber flow regulator in the head inlet is clear or remove it if the manufacturer permits. Replacement heads are £10–£30 and a low-scale design pays for itself in hard-water areas.

If the flow is poor with the head off as well, the restriction is upstream of the hose. Move on.

Step 2: Compare with another cold outlet

Before opening the shower, run the nearest cold tap — the basin or bath — and then the kitchen cold tap, which is usually the first draw off the rising main. Measure both.

Ask also whether the shower collapses when the toilet refills. If it does, the shower is sharing a 15mm supply with the cistern and is teed off downstream of it — a layout problem rather than a fault, fixed by re-plumbing the shower feed directly from the rising main.

Step 3: Inside the shower: isolation valve, filter, solenoid, heater can

Isolate the electrical supply at the pull-cord and the consumer unit and prove dead before removing the cover — electric showers run on 32–50A circuits (see safe isolation procedure). Turn off the water isolation valve.

Isolation valve. With the cover off, check the slot or handle of the service valve is fully in line with the pipe. A valve knocked a quarter closed during a tiling job or a previous repair is a common find and a free fix.

Inlet filter. Undo the inlet connection and remove the mesh strainer. Rinse out grit and scale, or replace it (a few pounds). A heavily silted filter in a house with no other symptoms usually means a recent mains disturbance — water company works, a new stopcock — stirred up sediment.

Solenoid valve and flow adjuster. Some units have a manual flow adjuster that may have been set to minimum; others have a stepped flow selector. A solenoid that is sticking or has a weak coil may not open fully and will usually also give intermittent "no water" symptoms, covered in electric shower not working.

Heater can. If the shower only reaches a comfortable temperature at a trickle, runs hotter than expected at a given setting, or has started tripping its thermal cut-out, the heater can is scaled and the waterway through it has narrowed. Descaling a can in situ is not practical or reliable; the realistic repair is a replacement can (£50–£120, where available for the model) or, for units more than eight to ten years old, a new shower. In hard-water areas a scale inhibitor fitted to the shower's supply extends the life of the replacement.

Step 4: The supply pipework

Trace the shower's cold feed back to the rising main. The ideal is a dedicated 15mm copper feed teed off the rising main as the first or second branch, with a full-bore isolation valve. Common faults:

Step 5: Stopcock, mains and the water company

If every cold outlet in the house is poor, start at the internal stopcock. Open it fully, then close it a quarter turn (to stop it seizing open) and remeasure. A stopcock whose jumper has come adrift, or whose washer has swollen, can present as a house-wide drop; replacing it with a full-bore lever valve is £80–£180 and often transforms the flow. See stopcock types.

Next check the external boundary stopcock is fully open — contractors and meter fitters routinely leave them part closed. Then put a gauge on the outside tap or washing machine valve with nothing else running: a static pressure below 1 bar, or a dynamic pressure that collapses below 1 bar when one tap runs, is a mains problem. If the supply pipe from the boundary is old lead or ½" galvanised, replacing it with 25mm or 32mm MDPE is the fix and is usually the customer's cost from the boundary inward; many water companies will replace their side free or subsidised at the same time.

If the pipe is sound and pressure at the boundary is still below the 10 metres head at 9 l/min reference level, the customer should raise it with the water company, who must investigate and may be liable for a payment under the Guaranteed Standards Scheme if the pressure falls below the standard on two occasions. Record your readings for them — a dated photograph of the gauge is the most useful thing you can leave behind.

Step 6: When the shower is simply too small for the job

If the flow with the head off is at or above the manufacturer's rated figure for the measured inlet temperature, and the customer still finds it weak, the shower is working correctly and the answer is more power or a different type of shower:

Explain the winter effect to the customer before they spend money: a 10.5 kW shower in January performs like an 8.5 kW shower in August. If they were happy in summer and unhappy in winter, the unit is not faulty.

Diagnostic decision tree

ELECTRIC SHOWER WEAK / "LOW PRESSURE"
│
├─ Measure flow at head, on COLD setting
│   └─ Remove head, remeasure
│       ├─ Much better with head off ──► descale / replace head
│       │                                  & flow regulator ──► DONE
│       └─ Still poor ──► continue
│
├─ Measure nearest cold tap AND kitchen cold tap
│   ├─ ALL poor ──► house supply / mains
│   │     ├─ Internal stopcock fully open? jumper intact? ──► replace with
│   │     │     full-bore lever valve
│   │     ├─ Boundary stopcock fully open?
│   │     ├─ PRV fitted? setting / failed? ──► adjust / replace / feed shower upstream
│   │     ├─ Lead / galvanised supply pipe? ──► replace in MDPE
│   │     └─ Static < 1 bar or dynamic < 1 bar at boundary ──► water company
│   │           (10 m head at 9 l/min reference level) ──► customer complaint
│   ├─ Kitchen fine, bathroom poor ──► bathroom pipework
│   │     ├─ Shower teed after WC/basin? drops when WC refills? ──► re-pipe
│   │     │     direct from rising main in 15 mm
│   │     ├─ 10 mm / microbore section? push-fit chain? ──► upsize in copper
│   │     └─ Corroded steel section? ──► replace
│   └─ Only shower poor ──► inside the unit (ISOLATE ELECTRICS FIRST)
│         ├─ Isolation valve fully open? ──► open
│         ├─ Inlet filter blocked? ──► clean / replace
│         ├─ Flow adjuster at minimum? ──► reset
│         ├─ Solenoid not opening fully? ──► replace solenoid
│         └─ Hot only at a trickle / TCO tripping? ──► heater can scaled
│               ──► replace can or unit; fit scale inhibitor
│
└─ Flow matches MI rating for inlet temperature?
    └─ YES ──► not a fault. Options: higher kW (check cable, Part P),
               mixer shower from combi/cylinder, or compliant mains boosting

Frequently Asked Questions

The shower was fine in the summer and is weak now it is winter. What has failed?

Probably nothing. An instantaneous shower heats water as it passes, so colder mains water in winter means the unit must slow the flow to reach the same temperature. An 8.5 kW shower that gave around 5.5 litres a minute with 16°C summer mains gives around 4 litres a minute with 8°C winter mains. Measure the flow on the cold setting: if it matches or exceeds the manufacturer's figure, the shower is working as designed. The cure for a customer who wants more in winter is a higher-rated unit, with the cable and circuit checked and the work notified under Part P.

Can I fit a pump to boost an electric shower?

Not an ordinary shower pump. Electric showers are mains-fed, and a pump drawing directly from the mains at more than 12 litres per minute requires notice to and consent from the water undertaker under the Water Supply (Water Fittings) Regulations 1999; most will refuse. The compliant options are a break tank and pump set or an accumulator vessel on the supply, which store water and release it at a stable pressure. Pumped electric showers exist for gravity (tank-fed) systems, but they are a specific product, not a standard shower with a pump added.

Is 1 bar enough for an electric shower?

Just. Most manufacturers specify 1.0 bar maintained (dynamic) pressure at the inlet with 8 litres a minute available, and a few models are rated down to 0.7 bar. The important word is maintained: a house with 3 bar static that drops to 0.8 bar as soon as the shower runs has an undersized supply pipe, not a pressure problem, and the readings at the shower will be poor however good the gauge looks with everything off.

Why does the shower go weak when someone flushes the toilet?

Because the shower and the cistern share a supply pipe and the cistern's fill valve is taking a share of a limited flow. The proper installation feeds the shower directly from the rising main in 15mm copper as one of the first branches, before any other bathroom outlet. Re-piping the feed is usually a half-day job and removes the problem; a flow-restricting fill valve on the WC is a cheaper partial fix.

How much should I charge to diagnose and fix a weak electric shower?

A call-out and diagnosis including descaling the head and cleaning the filter is typically £60–£100 and under an hour. Replacing a seized stopcock or a part-closed isolation valve is £80–£180. A like-for-like shower unit replacement is £150–£300 fitted, and re-piping the feed from the rising main is similar. An upgrade to a higher kW unit with a new circuit is a two-trade job at £600–£1,200+; see electric shower installation pricing guide. Always take the flow measurements first — they justify the quote and stop the customer paying for a shower when the stopcock was the fault.

Regulations & Standards