Summary

TV mounting is the archetypal small job: cheap for the customer, quick for the tradesperson, and badly priced by almost everyone. Handymen price it as half an hour and then spend two hours finding studs behind dot-and-dab plasterboard, cutting a chase for a cable kit the customer did not mention, and chasing a drill bit that has found the lintel. Electricians price it as a socket move and forget the bracket, the levelling and the customer standing behind them asking whether it looks straight. The result is a job that routinely earns less than the hourly rate on the van door.

The way to price it is to separate four things that customers lump together: fixing the bracket, supplying the bracket, hiding the cables, and providing power where the TV now hangs. Each is a different line with a different time, a different material cost and, for the power, a different legal status. Priced that way, a "TV on the wall" ranges from a £60 half-hour to a £400 half-day, and the customer sees why.

This guide gives the labour benchmarks for each wall type, the bracket and fixing costs, the right way to conceal cables under BS 7671:2018+A2:2022, the weight and VESA limits that decide the fixings, and the margins that make the job worth doing. It assumes a domestic customer and a TV from 32 to 85 inches; media walls with built-in joinery are priced separately in media wall installation pricing guide.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Job scope Labour Materials (trade) Typical price to customer (ex VAT, 2026)
Fix customer's bracket, solid or stud wall, cables visible 45–60 min Fixings £3–£8 £60–£90
Same, supply fixed or tilting bracket up to 55" 45–75 min £20–£50 £90–£150
Same, supply full-motion bracket 55–75" 60–90 min £50–£120 £140–£240
Dot-and-dab or aerated block wall, specialist fixings +30 min +£8–£15 +£30–£50
Chimney breast (disused flue), check and fix 60–120 min £10–£20 £120–£200
Surface cable management, trunking or cover strip +20 min £10–£25 +£30–£50
In-wall cable kit (recessed media plate, no mains) in stud wall +60–90 min £25–£50 +£90–£150
Recessed power kit with fused outlet behind TV, spur from existing socket, stud wall +90–120 min £40–£80 +£150–£250
Same in masonry with chase and making good +2–3 hours £50–£90 +£220–£350
Soundbar bracket or shelf +20–30 min £15–£40 +£40–£70

Detailed Guidance

Survey the wall before you quote

Three questions decide the price: what is the wall, where are the services, and where will the power come from.

Tap the wall. A dull thud with a slight give is plasterboard on studs; a hollow ring with a hard surface is dot-and-dab on masonry; a solid tap is plastered brick or block. On a stud wall, find the studs with a detector and a fine bradawl and mark them; most brackets want two fixings per stud at 400 mm or 600 mm centres. On dot-and-dab, the void behind the board is 10–25 mm, which is why standard plugs fail. On aerated block, which is common in houses built from the 1980s onwards, standard sleeve anchors crush the block and pull out; use a resin anchor or a fixing designed for lightweight block.

Scan for cables and pipes. Vertical runs above and below sockets and switches, horizontal runs at the top of the wall, and anything behind a radiator are the obvious ones, but a 1970s house with a chased cooker feed or a heating pipe dropped from the ceiling will surprise you. A combined detector finds most, not all; drill slowly with a masonry bit and stop if the resistance changes.

Decide the power. If there is a socket within 300 mm of the TV footprint and the customer accepts a short visible flex, no electrical work is needed. If the customer wants nothing visible, the only compliant route is fixed wiring in the wall to a recessed outlet behind the TV. Price that as an electrician's job even if you are the one doing it.

Fixing by wall type

Masonry (brick, dense block) — mark the bracket, drill with a 10 mm masonry bit to 90–100 mm, blow the dust out, fit M8 or M10 sleeve anchors or 10 × 100 mm frame fixings. Four fixings for anything over 25 kg or any full-motion arm. Torque the anchors until the bracket cannot be moved by hand; do not use an impact driver on sleeve anchors in old soft brick.

Timber stud — fixings go into the stud centre, not the edge. A full-motion arm on a single stud with two 6 × 80 mm screws will hold the static load but will work loose with repeated extension; use a bracket wide enough to catch two studs, or fit a 18 mm plywood backing board across three studs and fix the bracket to that.

Plasterboard, no stud available — only for fixed or tilting brackets and TVs under about 20 kg. Use metal cavity anchors or spring toggles rated by the manufacturer for the load, four minimum, and tell the customer in writing what the limit is. If the customer insists on a full-motion arm, the answer is a backing board or a different wall.

Dot-and-dab — use frame fixings long enough to pass through the board, the dab void and 50 mm into the masonry: 120 mm for a 10 mm void, 160 mm for a 25 mm void. Alternatively a dot-and-dab fixing with a metal sleeve that fills the void. Do not tighten standard plugs against the board; it crushes.

Chimney breast — check the flue is disused and capped, and look in the loft or at the pot for a vent. Drill no deeper than 60 mm into the breast face and keep fixings away from the centre line where the flue sits. If the room has a working gas fire or stove in that breast, the TV manufacturer's temperature limit usually rules the position out; put that in the quote as the reason.

Concealing cables the compliant way

The customer wants no wires. There are three ways to deliver that, and only two are legal.

  1. Low-voltage only — a pair of recessed plates (one behind the TV, one near the floor) joined by a flexible conduit or an open stud void carries HDMI, optical and aerial leads. No mains cable is involved. The TV's flex still has to reach a socket, which is why this is usually paired with option 2.

  2. Recessed power kit — a recessed outlet behind the TV, fed by fixed twin-and-earth from a fused connection unit or a spur off an existing socket below, following the safe zones of BS 7671:2018+A2:2022 Regulation 522.6.202 (vertically in line with the lower accessory is the easy one). The TV's short flex plugs in behind the screen. This is the standard solution, and it needs a Minor Works Certificate.

  3. Burying the TV flex — not permitted. Flexible cable is not a wiring system for concealment in a building fabric, and the plug on the end means it cannot be properly terminated at a fixed point. Decline this one however it is asked.

Keep mains and signal cables apart. Regulation 528.1 requires separation of band I (signal) and band II (mains) circuits unless the cables are insulated to the highest voltage present; in practice, run the HDMI in its own conduit or on the other side of the stud, not taped to the twin-and-earth.

Chases in masonry walls should not be deeper than one-third of the wall (or leaf) thickness for vertical chases or one-sixth for horizontal chases under Approved Document A, and horizontal chases in a half-brick wall are to be avoided; keep them vertical from the socket to the recessed outlet. Fill with bonding, then skim, then a coat of the customer's paint.

Fitting and levelling

Mark the centre line of the TV at the customer's chosen height: eye level seated is typically 1,000–1,100 mm to the screen centre in a living room and higher in a kitchen or bedroom. Hold the bracket, level it, and mark the fixings. Fix the wall plate first, then the TV plate to the back of the screen using the supplied screws of the correct thread (M6 or M8) and length; a screw that bottoms out on the chassis will crack the back of a modern thin TV. Two people for anything over 50 inches.

Hang, lock the safety screws, and check the screen is level with the TV's own frame rather than the bracket, because panels are not always square to their VESA plates. Plug in and prove every input works before you leave; a customer who finds the HDMI port is unreachable behind a fixed bracket will not pay the balance.

Pricing and margin

Build the quote from the table above rather than quoting a flat figure. A simple fix is a volume job: price it at £60–£90, do two or three in a morning, and the day works. A concealment-and-power job is a half-day with materials and a certificate: £250–£400 is a fair price and still cheaper than the customer's alternative of a surface trunking they hate. Add travel for a single short job; a 30-minute round trip on a £70 fix is the difference between profit and loss.

Materials are a small part of the job, so take a proper margin on them: a £45 full-motion bracket sells at £65–£80. Where the customer supplies the bracket, say in the quote that the fit is subject to the bracket being suitable for the wall and the TV, and that a second visit to swap it is chargeable.

Frequently Asked Questions

Can a handyman put a socket behind the TV?

Adding a socket or fused outlet to an existing circuit in a living room is not notifiable building work in England or Wales, so a competent person who is not registered with a scheme may do it, but it is still electrical work to BS 7671:2018+A2:2022 and the customer should receive a Minor Electrical Installation Works Certificate with test results. If you cannot test insulation resistance, polarity and earth fault loop impedance, sub-contract the outlet to an electrician and price the rest. In Scotland the rules are stricter and the work should be done by an approved certifier.

What is the heaviest TV I can put on a plasterboard wall?

If there are no studs behind the fixings, the practical limit for a fixed or tilting bracket is about 20 kg with four rated cavity anchors in 12.5 mm board, and no full-motion arm at all. With two timber studs available there is no realistic domestic TV that cannot be hung. The right answer to "there are no studs where I want it" is a plywood backing board fixed to the studs that are there, finished in the wall colour.

The customer wants the TV above a working fireplace. Is that a problem?

Usually yes. Most manufacturers specify a maximum operating temperature around 35–40°C and heat from a gas fire or stove rises up the breast face well past that. It also puts the screen too high to watch comfortably. Offer a full-motion bracket that pulls down and away, or a mantel-mounted alternative, and record in the quote that the position was the customer's choice against your advice.

Should I offer to set the TV up and tune it?

Yes, as a priced extra of 20–30 minutes. Scanning channels, connecting Wi-Fi and pairing a soundbar is the part of the job the customer actually sees working, and it stops the "it worked when you left" call. Do not price it into the fix; itemise it.

Regulations & Standards