Summary
"Can you replace my shower valve?" is one of the highest-frequency small plumbing jobs in the country, and one of the easiest to underquote. The customer sees a chrome bar with two knobs and expects an hour. Half the time that is right: an exposed bar mixer on standard 150 mm centres with sound isolation valves is a lift-off, lift-on job, and the only decision is which valve. The other half, the valve is concealed in the wall with the tiles over it, the isolation valves are seized or absent, the centres are the old 155 mm or 165 mm, the pipework is 15 mm with a 22 mm valve, or the "shower valve" is the cartridge inside a 20-year-old exposed valve nobody makes any more. Those are not an hour.
This guide prices the five versions of the job — cartridge, exposed like-for-like, exposed with pipework alterations, concealed like-for-like, concealed with tiling — by labour hours and materials, with regional and London figures, and gives the survey questions that decide which version it is. It covers the valve types and approvals, the system-matching rule that stops the call-back, and a worked quote. For the valve technology see thermostatic mixing valves and thermostatic vs manual mixer shower comparison; for a whole new shower enclosure the job is shower installation pricing guide.
Key Facts
- Exposed bar mixer, like-for-like, 150 mm centres — 1–2 hours; valve £70–£180 trade (mid-range) or £40–£70 (budget); fitted £150–£300 regionally, £200–£380 London
- Exposed bar mixer with riser rail and handset kit — add £30–£80 for the kit and 20–30 minutes; fitted £190–£360
- Exposed valve, centres or pipework need altering — 2–3 hours; offset connectors or new tails £15–£40; fitted £220–£400. Old valves on 155 mm or 165 mm centres need adjustable or offset fixing centres, which most bar mixers include within ±5–8 mm
- Concealed valve, like-for-like same manufacturer body — 3–4 hours; valve/trim £120–£400; fitted £450–£850. Only possible where the same manufacturer's body is still current and the new trim fits
- Concealed valve, different body (tiles out) — 5–8 hours over two visits (plus tile drying time); valve £120–£400, tiles/adhesive/grout £40–£120; fitted £650–£1,300. Add a tiler if the customer wants an invisible repair; spare tiles from the original batch are the deciding factor
- Cartridge replacement only — 30–60 minutes; cartridge £30–£90 (manufacturer part); fitted £90–£180. Only where the body is sound and the cartridge is still available; a failed cartridge on a discontinued valve is a valve replacement
- Digital shower valve — 2–4 hours, controller £300–£700, plus a fused spur if not present (Part P: a new spur from an existing circuit outside a bathroom zone is not notifiable; a new circuit is); fitted £500–£1,100
- High pressure vs low pressure — combi or unvented cylinder (1–3 bar): valve to BS EN 1111; gravity cylinder (0.1–0.5 bar): valve to BS EN 1287, or a pumped supply. A BS EN 1111 valve on a 0.2 bar gravity system runs cold and dribbles; this is the number-one "new valve doesn't work" complaint
- Minimum pressure — typical bar mixers need 0.5–1.0 bar dynamic minimum on both supplies for the thermostat to control; low-pressure variants work from 0.1–0.2 bar; check the data sheet
- Balanced supplies — thermostatic valves need hot and cold at similar pressures; combi hot and mains cold are balanced; cistern-fed hot with mains cold is not, and needs a pressure-reducing valve on the cold, a pumped hot, or an all-gravity arrangement
- Check valves — WRAS requires backflow protection where hot and cold meet; all approved thermostatic mixers have integral single check valves on both inlets; if the old valve had none, the pipework may have been relying on none, so do not remove them
- Isolation — fit or replace 15 mm isolation valves on both supplies while the valve is off (£3–£6 each, 10 minutes); the next cartridge change is then a 30-minute job rather than a drain-down
- WRAS / Regulation 4 approval — the valve must be an approved fitting under the Water Supply (Water Fittings) Regulations 1999; cheap unbranded online valves frequently are not. TMV2 scheme approval (to BS EN 1111 and BS EN 1287) is the mark for a domestic valve; TMV3 (NHS D 08) is for care settings and not needed in a house
- Approved Document G3(4) — in new dwellings the hot water at a bath outlet is limited to 48 °C; a thermostatic shower valve set to a maximum of 41–43 °C satisfies the intent for showers and the TMV at the bath does the bath; not retrospective on a replacement, but set the maximum stop on the new valve anyway
- Scald guidance — 60 °C water scalds in about 1 second; 54 °C in about 30 seconds; most thermostatic valves have an override button at 38 °C and a maximum stop adjustable to 43–46 °C
- Guarantee — most valves carry 5–10 years on the body and 1–2 years on the cartridge; register it for the customer and note the terms on the invoice
- Markup — 20–30% on the valve; or supply at trade and carry margin in labour. See markup to margin explained
Quick Reference Table
Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.
Try squote free →| Job | Time | Valve / parts (trade) | Fitted, regional | Fitted, London | Notes |
|---|---|---|---|---|---|
| Cartridge swap, body sound | 30–60 min | £30–£90 | £90–£180 | £120–£220 | Manufacturer part; check availability first |
| Exposed bar mixer, like-for-like, 150 mm centres | 1–2 h | £70–£180 | £150–£300 | £200–£380 | Includes new isolation valves |
| Exposed bar mixer with riser rail kit | 1.5–2.5 h | £100–£260 | £190–£360 | £240–£450 | Rail, hose, handset |
| Exposed valve, offset centres or new tails | 2–3 h | £90–£220 | £220–£400 | £280–£500 | Chase or surface pipework |
| Concealed valve, same body, new trim/cartridge | 2–3 h | £80–£250 | £250–£500 | £320–£620 | Where the body is still current |
| Concealed valve, same manufacturer body swap, no tiling | 3–4 h | £120–£400 | £450–£850 | £550–£1,000 | Body fits the existing recess |
| Concealed valve, different body, tiles out and made good | 5–8 h, 2 visits | £160–£520 | £650–£1,300 | £800–£1,600 | Tile match is the risk; price tiling separately |
| Digital valve and controller | 2–4 h | £300–£700 | £500–£1,100 | £620–£1,350 | Fused spur; check Part P |
| Low-pressure (gravity) valve plus pump | Half a day | £250–£500 | £500–£900 | £620–£1,100 | Dedicated feeds; see shower pump guide |
Detailed Guidance
The survey questions that decide the price
Five questions over the phone or on the first visit put the job in the right row of the table:
- Exposed or concealed? If the valve body is visible on the wall with pipes entering from behind, it is exposed. If only a plate and controls show, it is concealed, and the price doubles or trebles.
- What system? Combi, unvented cylinder, or a cylinder in the airing cupboard with a tank in the loft. This decides high-pressure or low-pressure valve and whether the supplies are balanced.
- Are there isolation valves and do they work? No isolators on a gravity system means a cistern tie-up and drain-down; no isolators on a combi means isolating at the boiler and the stop tap and draining the hot run. Add 30–45 minutes.
- What is the make and model? For a concealed valve, whether the manufacturer still makes the body is the whole job. A photograph of the trim and any markings, or the installation booklet, tells you. Many manufacturers' bodies have stayed the same for 15–20 years precisely so trims can be updated; others changed every five years.
- Spare tiles? If the body must change, the recess is coming out. Original tiles in the garage make it an invisible repair; no spares means a feature panel, a larger plate, or a conversation about retiling the wall.
Exposed bar mixers: the hour-and-a-half job
Isolate both supplies. Undo the two nuts behind the valve body, lift it off the fixing centres (the elbows screwed into the wall). Check the elbows: 150 mm centres with ½ inch BSP male threads is the modern standard; most new bar mixers come with fixing centres that adjust ±5–8 mm to take up old 155 mm or 165 mm spacing, and with wall-plate elbows if the old ones are tired. Fit new isolation valves if the supplies lack them. Fit the new elbows with PTFE and a seal, check with a level, fit the new valve with its filters and check valves, open the supplies, check for leaks, set the maximum temperature stop (41–43 °C at the handset is the usual setting; measure it with a probe thermometer), and show the customer the 38 °C override button. Ninety minutes with a clean removal, two hours if an elbow shears in the wall. Chrome-plated brass elbows are better value than the plated zinc ones that come free in the box.
Concealed valves: why the price is honest
A concealed valve's body sits in a recess in the wall with the pipework made to it and the tiles cut around it. Replacing the cartridge or the trim is an easy job if the parts exist. Replacing the body means either the same manufacturer's current body that fits the same recess and pipe positions — sometimes true for the long-lived ranges — or cutting out tiles, removing the body, re-making the pipework to the new body's connections (often different spacings and depths), fitting it to the correct depth for the finished tile face (the biggest error: a body set too deep or too shallow for the new trim), re-boarding or re-rendering, tiling, grouting, and a second visit to fit the trim. It is a half-day plus a return, and the price in the table reflects it. Quote the tiling as a separate line, state that a perfect match depends on spare tiles, and photograph the wall before you start.
Matching the valve to the system
This is the rule that stops the "it's still cold" call. Thermostatic valves need a minimum dynamic pressure on both inlets to control, and need the two inlets within a reasonable ratio of each other (manufacturers typically specify up to about 5:1, some less).
| System | Hot pressure | Cold pressure | Valve type | Notes |
|---|---|---|---|---|
| Combi boiler | Mains (1–3 bar) | Mains | High pressure, BS EN 1111 | Balanced; the easy case. Flow limited by combi output, see combi boiler flow rate explained |
| Unvented cylinder | Mains via PRV (typically 3 bar) | Mains, ideally via the same PRV (balanced cold take-off) | High pressure, BS EN 1111 | Take the cold from the cylinder's balanced connection, not raw mains |
| Gravity cylinder, cistern-fed cold to the shower | 0.1–0.5 bar | 0.1–0.5 bar | Low pressure, BS EN 1287, or pumped | Balanced but weak; a twin-impeller pump transforms it |
| Gravity cylinder, mains cold to the shower | 0.1–0.5 bar | 1–3 bar | Unbalanced — do not fit a standard valve | Fit a PRV on the cold, or re-feed cold from the cistern, or pump the hot |
If a customer's existing valve is a cheap online high-pressure unit on a gravity system, replacing it with the same thing changes nothing. Quote the right valve, or the pump, and explain the difference — see shower pump installation and shower pump installation pricing guide.
Valve types and what to charge for them
- Bar mixer, exposed (£40–£180 trade): the default replacement. Thermostatic cartridge with a 38 °C stop, two check valves, two filters. Mid-range brands carry 5–10 year guarantees and have cartridges available for years; budget units often do not.
- Sequential or dual-control concealed (£120–£400): the built-in look. Specify the body and trim as a kit from one manufacturer.
- Thermostatic with diverter (£150–£450): one valve serving a fixed head and a handset, or a bath filler and a shower. Count the outlets before quoting.
- Digital (£300–£700): remote controller, a mixer unit in the loft or airing cupboard, often with a pump option for gravity systems. Needs a fused spur and a data cable; a good answer where the wall cannot be opened because the mixer unit goes elsewhere.
- Low-pressure (gravity) bar mixers (£80–£200): larger waterways and a cartridge that works from 0.1 bar; the honest option on an unpumped gravity system.
Avoid naming brands on the quote beyond the model the customer has chosen; describe the type, the approval (WRAS/TMV2), the guarantee and the pressure rating.
Worked quote: exposed bar mixer, combi system, Leeds
Customer's 12-year-old exposed thermostatic bar mixer drips from the body and has lost temperature control; cartridge discontinued. Combi boiler, 150 mm centres, isolation valves present but seized.
Materials:
Thermostatic bar mixer, WRAS/TMV2, high pressure, 10-yr guarantee £115
2 × 15 mm full-bore isolation valves £9
Chrome fixing-centre elbows (upgrade from supplied) £14
PTFE, seals, silicone £4
£142
Markup 25% £36
Materials charged £178
Labour:
Isolate at boiler and stop tap, drain hot run, remove old valve
and seized isolators, fit new isolators and elbows, fit valve,
test, set max temperature stop, demonstrate 1.75 h
1.75 h × £48/h = £84 → charge £90
Quote (ex VAT) £268
The customer was quoted £250–£300 on the phone from the table above, so the figure lands where they expected. The seized isolators were the risk item; they were named in the quote as "replace isolation valves if seized, included".
What goes wrong, and what to exclude
- Sheared elbows. A ½ inch BSP elbow that snaps off in a tiled wall becomes a chased-out repair. Exclude it: "if existing wall elbows cannot be removed without damage to tiling, additional work will be quoted."
- No hot at the valve. Diagnosed on the first visit, not after fitting: a gravity system with no head at a loft shower was never going to work with a new bar mixer.
- Wrong centres. Measure before ordering; 165 mm Victorian-pattern centres need specific offset elbows.
- Scale. In hard-water areas a new cartridge on an old scaled body fails early; recommend a valve replacement rather than a cartridge, and a scale reducer if the house has none.
- The riser rail holes. A new rail rarely matches the old fixings; two extra holes in the tiles are part of the job and worth saying.
Frequently Asked Questions
How much does it cost to replace a shower valve in the UK?
An exposed thermostatic bar mixer replaced like-for-like costs £150–£300 fitted regionally and £200–£380 in London, including a mid-range WRAS-approved valve. A concealed valve where the body must change and the tiles come out costs £650–£1,300, more if tiling cannot be matched. A cartridge replacement on a sound valve is £90–£180.
How long does it take to replace a shower mixer valve?
One to two hours for an exposed bar mixer on standard 150 mm centres with working isolation valves. Add 30–45 minutes if the supplies must be drained because there are no isolators, two to three hours if the centres or pipework need altering, and a half day plus a return visit for a concealed valve that needs the tiles removed.
Can I replace a shower valve myself?
An exposed bar mixer is within a competent DIYer's reach if the isolation valves work, but the valve must be an approved fitting under the Water Supply (Water Fittings) Regulations 1999 and must suit the system's pressure, and the maximum temperature stop needs setting with a thermometer. Concealed valves, gravity systems without balanced supplies, and anything needing a pump or a fused spur are tradesperson jobs.
Why does my new shower valve run cold?
Usually a pressure mismatch: a high-pressure (BS EN 1111) valve fitted to a gravity hot water system with 0.1–0.3 bar of head, or a gravity hot supply paired with a mains cold so the cold overpowers the hot. Less often, a blocked inlet filter or a check valve fitted backwards. Match the valve to the system or fit a pump or pressure-reducing valve.
Do I need a thermostatic shower valve by law?
In new dwellings in England, Approved Document G3(4) requires a thermostatic mixing valve limiting bath hot water to 48 °C; showers are covered by good practice rather than a specific figure. In existing homes there is no legal requirement to change a manual valve, but a thermostatic valve with the maximum stop set is the standard recommendation, especially where children or older people use the shower.
Regulations & Standards
Water Supply (Water Fittings) Regulations 1999 (SI 1999/1148) — Regulation 4 approved fittings; Schedule 2 backflow prevention at hot/cold mixing points
Building Regulations 2010, Approved Document G (2015 edition with 2016 amendments) — G3(4) bath outlet temperature limit of 48 °C in new dwellings; G3 hot water systems
BS EN 1111:2017 — sanitary tapware; thermostatic mixing valves (PN 10) for high-pressure systems
BS EN 1287:2017 — sanitary tapware; low-pressure thermostatic mixing valves
TMV2 scheme (BEAMA/BMA) — third-party approval of thermostatic mixing valves to BS EN 1111 and BS EN 1287 for domestic use
NHS Estates D 08 / TMV3 scheme — thermostatic mixing valves for healthcare and care premises (not required domestically)
BS EN 806-2:2005 — design of installations inside buildings conveying water; pipe sizing and pressures at outlets
BS 8558:2015 — guide to design and installation of domestic water services; balanced supplies and dead legs
Building Regulations 2010, Approved Document P (2013 edition) — electrical work for digital valves and pumps; bathroom zones
BS 7671:2018+A4:2026 — Section 701 locations containing a bath or shower; supplies to pumps and digital controllers
Consumer Rights Act 2015 — goods and services of satisfactory quality; the valve guarantee and your workmanship
Approved Document G: Sanitation, hot water safety and water efficiency — gov.uk; G3(4) temperature limit
Water Supply (Water Fittings) Regulations 1999 — legislation.gov.uk
WRAS — Water Regulations Advisory Scheme — approved fittings directory
TMV2 scheme — BEAMA — thermostatic mixing valve approvals for domestic use
Bathroom Manufacturers Association — thermostatic showers guidance — selection and pressure matching
CIPHE — Chartered Institute of Plumbing and Heating Engineering — installer guidance
thermostatic mixing valves — how TMVs work and the approval schemes
thermostatic vs manual mixer shower comparison — which valve type to recommend
shower types — mixer, electric, power and digital showers
combi boiler flow rate explained — the flow a combi can give the new valve
water pressure flow rate — measuring the pressures that decide the valve
shower pump installation — when a gravity system needs a pump
shower pump installation pricing guide — pricing the pump
shower installation pricing guide — the full enclosure job
plumber hourly rate guide — the rates behind the figures