Summary

Solar panel cleaning is a service that sells on a number the customer can see: generation. A dirty array in a UK climate loses 3–8% of output on average, more where there is bird soiling under a roost, tree pollen, lichen growth on older panels, or agricultural dust, and the inverter app shows the drop. A clean restores it. The trade problem is that cleaning looks easy — it is window cleaning on a roof — and the price the market expects (£5 a panel) only works from the ground with a water-fed pole on a modern two-storey house with the array on the front pitch. The same array on a rear pitch over a conservatory, or a bungalow with a low eaves and a steep pitch the pole cannot reach along, or a 30-panel array on a three-storey townhouse, is a tower or a roof-access job and costs three times as much to do safely.

The second trade problem is safety. The Work at Height Regulations 2005 apply to every solar cleaning job, and a ladder is not a working platform for a 90-minute clean. Cleaners who go onto the roof need edge protection or fall arrest and a roof ladder; cleaners who work from the ground need a pole that reaches, which caps the practical reach at about 18–20 m with a carbon-fibre pole and realistically 12–15 m for control. Pricing has to start from the access method, and the quote has to say which one. This guide gives the per-panel and per-visit figures, the equipment and consumable costs, the labour times by access method, the add-ons that make the visit worth more, and the commercial and ground-mount rates.

For what to offer alongside cleaning see solar pv cleaning and maintenance; for the system itself see solar pv; for access see working at height.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Job Regional (outside London/SE) South East London Notes
Domestic, 6–10 panels, from the ground £80–£130 £90–£150 £110–£180 Minimum call-out applies
Domestic, 10–14 panels, from the ground £100–£180 £120–£200 £150–£240 Typical 4 kWp array
Domestic, 14–20 panels, from the ground £140–£220 £160–£250 £200–£300
Domestic, any size, tower required +£60–£120 +£70–£140 +£90–£160 Tower hire and 1 hr set-up/strike
Domestic, roof access with fall protection £150–£300 £180–£350 £220–£420 Two operatives recommended
In-roof / integrated panels (flush, harder to edge) +10–20% +10–20% +10–20% Water and debris sit at the frame line
Bird-proofing mesh, per linear metre £15–£30 £18–£32 £20–£38 Supplied and fitted during the clean
Visual inspection and inverter reading, written report £40–£80 £45–£90 £55–£100 Add-on
Commercial roof-mount, per panel (100+) £1.50–£4 £1.80–£4.50 £2–£5 Access priced separately
Commercial per kWp £15–£35 £18–£38 £20–£45
Ground-mount, per panel (500+) £0.80–£2 £0.80–£2 £0.80–£2 Mechanised
Annual service contract (clean + inspection), domestic £150–£260 £170–£290 £200–£340 Billed yearly, booked in advance

Detailed Guidance

Price from the access method, not the panel count

Before quoting, establish how the array will be reached:

Situation Access Time, 12 panels Price basis
Two-storey house, array on a pitch facing an accessible garden or drive, eaves 5–6 m Water-fed pole from the ground 60–90 min Per panel, £4–£10
Array on a pitch over a conservatory, extension or narrow side return Pole from a tower or from the flat roof with edge protection 2–2.5 hrs Per panel + tower uplift
Bungalow, low eaves, steep pitch, array runs up to the ridge Pole from the ground usually reaches; check angle 60–90 min Per panel
Three-storey townhouse, eaves 8–9 m Long pole (16–18 m) from the ground if reach allows, otherwise tower or MEWP 1.5–3 hrs Per panel + uplift
Array on the far side of a pitch, no ground access Roof access with roof ladder, harness and anchor; two operatives 3–4 hrs Roof-access rate
Commercial flat roof with parapet Walk the roof with edge protection; pole or hand brush per panel Commercial rate + access

Say in the quote which method is priced and what happens if the access on the day is different ("priced from the ground; if a tower is required on arrival, +£90"). A cleaner who turns up with a 12 m pole for a job that needs 16 m goes home unpaid.

Labour time and the hourly rate behind the per-panel price

A sole-trader solar cleaner's cost base is lower than a plumber's — no stock, cheaper tools — but the van, the water system and the insurance still have to be recovered, and the work is seasonal (March to October, with a spring rush when the output drop becomes visible). A reasonable day rate target is £200–£280, which on 6 billable hours is £35–£45 an hour. At 7 minutes a panel from the ground plus 30 minutes set-up and strike, a 12-panel clean is about 1.75 hours: £60–£80 of labour, plus water (£2–£4), plus travel. That is the floor under a £100–£140 price for the job and the reason the per-panel rate has to come with a minimum call-out. Two 12-panel jobs in a morning and two in the afternoon is £450–£600 a day in season, which is the whole business model, and it depends on routing the jobs by postcode and booking a street at a time.

Water, equipment and consumables

Water is charged inside the per-panel price, not as a line. Bird mesh, clips and replacements are materials at trade cost plus 20–30%.

Add-ons that turn a clean into a service visit

The margin in solar cleaning is in the visit, not the panels:

Keep electrical work out of the visit unless the operative is qualified for it: a loose MC4 connector or a tripped DC isolator is a report item for a solar electrician, not something a cleaner opens. See solar pv not generating for what the customer should be told to do next.

Commercial and ground-mount arrays

Commercial pricing is per panel on volume or per kWp, with access as a separate line. A 400-panel warehouse roof at £2.50 a panel is £1,000 for the clean, plus a MEWP at £250–£400 a day if the roof cannot be walked, plus the edge-protection or harness set-up, plus a RAMS pack the facilities manager will want (two hours of desk time). Two operatives at 150–200 panels a day each sets the labour. Ground-mounted arrays and solar farms are a different business — tractor-mounted rotating brush systems, water bowsers and a per-MW price — and a domestic cleaner should quote them only as a subcontractor to a specialist.

Warranty, manufacturer guidance and what to put in writing

Most panel manufacturers' installation and maintenance guidance specifies cleaning with water and a soft brush or sponge, no abrasives, no high-pressure water, no solvents, and no cleaning when the glass is hot (thermal shock risk — clean early morning or on overcast days in summer). State on the quote that cleaning is with purified water and a soft brush only, that no detergent or pressure washing is used, and that the operative will not walk on the panels. That protects the customer's warranty and protects you when a pre-existing micro-crack shows up a month later: the before-and-after photographs are the evidence. See solar pv cleaning and maintenance for the customer-facing version.

Worked example: 14-panel array, two-storey semi, front pitch, from the ground

Travel and set-up (tank, pole, hoses, TDS check)            30 min
Clean 14 panels at 7 min each                               98 min
Rinse, inverter reading, 6 photographs, strike              20 min
                                                            --------
On site                                                     ~2.5 hrs

Labour at £40/hr                                             £100
Water: 110 litres DI at £1.20 per 100 litres                  £1.50
Van and travel (in the day rate)                             —
Price quoted: 14 panels × £8 = £112, rounded to              £120
Add-on sold: inspection and report                            £50
Add-on sold: bird mesh, 9 m perimeter at £22/m               £198
Invoice                                                      £368

The clean alone is £120 for 2.5 hours — adequate. The visit is £368 for about 3.5 hours, with the mesh at a 25% materials margin — that is the business.

Frequently Asked Questions

How much should I charge to clean solar panels?

£4–£10 per panel from the ground with a £80–£150 minimum, so a typical 10–14 panel domestic array is £100–£180 in 2026. If a tower is needed add £60–£120; if roof access with fall protection is needed, £150–£300 for the same array. Commercial arrays £1.50–£4 per panel on volume, access extra.

Can I use a pressure washer or washing-up liquid?

No. Pressure washers can force water past the frame seal and crack cells; detergents leave a film that attracts dirt and most manufacturers' warranties exclude them. Purified water (under 10 ppm TDS) with a soft brush is the industry standard and the one that keeps the customer's warranty intact.

Is it safe to clean solar panels from a ladder?

Not as a working platform. The Work at Height Regulations 2005 allow ladders only for low-risk, short-duration work, and a 90-minute clean is neither. Work from the ground with a water-fed pole, from a tower, or from the roof with a roof ladder and a harness anchored to a rated point. Never stand or walk on the panels.

How often should solar panels be cleaned in the UK?

Once a year for most domestic arrays; twice a year under trees, near the coast, under a bird roost or on a farm. Rain removes loose dust but not pollen film, lichen, bird droppings or the dirt line along the bottom frame edge, and the inverter app shows the difference after a clean.

Should I offer an annual contract?

Yes. A clean plus a 20-minute visual inspection and a one-page report, booked for the same month each year at £150–£260, gives the customer a reason to keep you and gives you a base income you can route by postcode. It is also the natural point to sell bird-proofing and to spot a failing inverter or a cracked panel before the customer notices a generation drop.

Regulations & Standards