Summary
Oven installation is the kitchen-fit job where the labour cost depends almost entirely on what's behind the unit, not the oven itself. A plug-and-go single oven on an existing 32A cooker circuit takes 30 minutes; the same oven where the customer has just torn out an old gas range and now needs a new electrical circuit run from the consumer unit is a full-day job for a Part P electrician with circuit-test certification.
Gas oven installation is now a smaller market — most replacement ovens are electric — but the gas work still happens, especially in older Aga, Rangemaster and Belling installs. Any gas connection MUST be made by a Gas Safe registered engineer for the appliance type (cooker = standard domestic gas qualification). The pricing reflects Gas Safe overhead and tightness-testing time.
This guide covers labour bands by appliance type (single electric, double electric, gas, range), electrical scope (plug-in, fused spur, dedicated circuit), and worked pricing for the four most common UK domestic install scenarios. For matching kitchen-appliance work see hob installation pricing guide and cooker hood installation pricing guide.
Key Facts
- Single electric oven, plug-in to existing cooker socket — £80–£150 labour, 30–60 min
- Single electric oven, new fused spur from ring — £120–£200 labour, 1–2 hr (≤3kW only)
- Single electric oven, new 32A cooker circuit from CU — £280–£500 labour, half-day
- Double electric oven, plug-in to existing cooker socket — £100–£180 labour, 1 hr
- Double electric oven, new 32A circuit — £320–£550 labour, half-day
- Gas oven, like-for-like swap, bayonet fitting — £140–£260 labour, 1.5–2 hr
- Gas oven, new install with new copper run — £280–£500 labour, half-day
- Range cooker (electric, 8–10kW) — £350–£650 labour, 3–5 hr (typically 6mm² circuit)
- Range cooker (gas, ≥30kW total) — £400–£750 labour, half-day
- Electrician day rate — £280–£480 regional, £360–£560 London (Part P registered)
- Gas Safe engineer day rate — £300–£500 regional, £400–£600 London
- 45A cooker switch (DP, with neon) — £14–£28 supplied
- 45A cooker switch with 13A socket — £22–£42 supplied
- 45A cooker connection unit (CCU, under-counter) — £8–£16 supplied
- 6mm² T+E twin-and-earth (10m) — £35–£60 supplied
- 6mm² T+E cable per metre — £3.50–£6.00 supplied
- 32A MCB (B-type, single module) — £8–£18 supplied
- 32A RCBO (single module, A-type) — £18–£35 supplied
- Gas cooker bayonet (LCC1 micropoint) — £18–£32 supplied
- Flexible gas hose (1m, LCC1-compliant) — £24–£42 supplied
- Tightness test (Gas Safe) — £40–£80 included in install
- Notification — Part P circuit additions notifiable via registered competent person scheme (NICEIC, NAPIT, Stroma, ELECSA)
- VAT — 20% standard rate
Quick Reference Table
Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.
Try squote free →| Scenario | Time | Labour Only | Materials | Full Fitted Price |
|---|---|---|---|---|
| Single electric oven, plug-in swap | 30–60 min | £80–£150 | £0–£20 | £80–£170 |
| Single electric oven, fused spur from ring (≤3kW) | 1–2 hr | £120–£200 | £20–£45 | £140–£245 |
| Single electric oven, new 32A circuit + switch | 4–6 hr | £280–£500 | £80–£160 | £360–£660 |
| Double electric oven, plug-in to existing cooker socket | 1 hr | £100–£180 | £0–£25 | £100–£205 |
| Double electric oven, new 32A circuit | 4–6 hr | £320–£550 | £100–£180 | £420–£730 |
| Gas oven, like-for-like bayonet swap + tightness test | 1.5–2 hr | £140–£260 | £20–£60 | £160–£320 |
| Gas oven, new copper run + bayonet + tightness test | 4–6 hr | £280–£500 | £80–£160 | £360–£660 |
| Range cooker (electric, 8kW), new 32A radial | 5–7 hr | £350–£650 | £120–£220 | £470–£870 |
| Range cooker (gas, dual-fuel), gas + 13A spur | 5–8 hr | £400–£750 | £150–£280 | £550–£1,030 |
Detailed Guidance
Electric Ovens — Which Circuit?
The circuit decision depends on rated power:
- ≤3kW (13A) — a fused spur from the kitchen ring final via a 13A switched fused connection unit (FCU) is acceptable. Many modern single ovens (2.5–3.0 kW) fit this category. The advantage: no new circuit, no notification. Use this where the kitchen ring exists and capacity allows.
- 3–7.4 kW (single oven, large or pyrolytic; or double oven) — a dedicated 32A radial circuit in 6mm² T+E from the consumer unit (CU) to a 45A cooker switch, with a connection unit behind the oven. Notifiable under Part P.
- 7.4–10 kW (range cookers) — typically 32A B-type MCB on 6mm² T+E; check manufacturer's specified circuit current and apply BS 7671 diversity factor for cookers (first 10A at 100%, remainder at 30%, plus 5A if a socket is included in the cooker switch).
For diversity calculation on a 10kW range (43.5A connected load): 10A + (33.5 × 0.3) = 20.05A demand. A 32A circuit is adequate. Do not size the circuit on connected load alone — apply Regulation 311.1 / Appendix 4 of BS 7671 diversity factor.
The Cooker Switch — Where and Why
BS 7671 requires a means of isolation for fixed-wired cooking appliances. The 45A double-pole (DP) cooker switch with neon indicator is the standard solution:
- Located within 2m of the cooker, but not directly above it
- Within reach of the user without bending or stretching across the hob
- A second connection unit (CCU) is typically fitted below the worktop behind the oven so the oven can be pulled out for servicing without dismantling the switch
The 45A cooker switch with integral 13A socket is popular but is gradually being deprecated where worktop sockets are available elsewhere — the worktop socket cluttered with toaster/kettle leads is a fire risk and not preferred.
Gas Ovens — Bayonet and Test
Gas oven connection uses an LCC1 bayonet fitting (the "micropoint") with a self-sealing valve. The flexible hose is also LCC1-compliant, with a 5-year lifespan stamped on it; check the date code and replace if expired even on a like-for-like swap.
The Gas Safe install sequence:
- Visual check of existing gas point and pipework
- Disconnect old oven; cap and pressure-test if any pipework alteration
- Inspect new oven for damage in transit
- Connect new bayonet hose, slide oven into position
- Check hose has no kinks, no fouling on hot surfaces, no stretching
- Soundness (tightness) test on the installation per IGEM/UP/1B for domestic
- Function-test all burners and oven element
- Issue installation record / receipt; for new installs, notify via Gas Safe app
A bayonet swap typically takes 1.5–2 hours including the test. A new run with copper pipework, isolation valve and bayonet termination is half a day.
Pricing the Notification
Part P notification for a new electrical circuit:
- Self-certifying installer (NICEIC, NAPIT, etc.) — included in the day rate; certificate issued to customer
- Non-registered installer — must engage Building Control. Domestic Building Control fee: £200–£500 typical for small electrical work. Time: 1–2 hours of additional admin and a wait for the inspector.
Always quote the notified route. Customers reading "£500 for a circuit" can compare like-for-like with another quote. Customers reading "£280 for the labour, plus Building Control fees you'll need to pay" will pick the £280 quote even though it ends up more expensive.
Common Site Overruns
- No existing 32A cooker circuit — customer assumed there was one; circuit must be run from CU.
- CU full — no spare way in consumer unit; either a CU change (£500–£900) or a sub-board (£250–£400).
- CU is old (pre-RCD) — current Part P/BS 7671 requires RCD protection on circuits under floors / in walls. Adding a single RCBO may need a CU change.
- Bayonet hose past date code — must be replaced (£24–£42).
- Gas hob present without correct spillage — flue-spillage test required when ducted cooker hood + gas hob + open-flued appliance share a room. Adds 30+ minutes.
- Oven won't fit cabinet aperture — old "60cm" aperture is actually 59.5cm; new oven needs 60.0cm. Cabinet modification.
Frequently Asked Questions
Can I install an electric oven myself?
You can mechanically install (slide into cabinet, connect to an existing 13A plug if the oven is ≤3kW with a fitted plug, level and trim). You cannot run a new 32A cooker circuit yourself without notifying Building Control unless you are Part P registered. Most replacement electric ovens are NOT supplied with a 13A plug — they have a free end requiring connection to a cooker connection unit, which is a fixed-wired installation.
Is a 13A fused spur acceptable for a 3.6 kW oven?
No — a 3.6 kW oven draws 15.7 A at full load, exceeding the 13 A fuse rating. The manufacturer's stated load determines the circuit. Round up to a 32A radial circuit on 6mm² cable, terminated at a 45A cooker switch.
Who can install a gas oven?
A Gas Safe registered engineer with category "Cookers" on their card (most domestic gas engineers carry this). The customer should check the card and the Gas Safe Register (gassaferegister.co.uk) before allowing work. A non-registered installer working on gas is an offence under the Gas Safety (Installation and Use) Regulations 1998, Regulation 3.
Does a hard-wired oven need an isolator?
Yes. BS 7671 Regulation 462.2 requires a means of isolation for fixed wired equipment, and Regulation 132.15 requires it to be accessible. The 45A DP cooker switch satisfies this; a remote isolator at the CU does not, because the user must be able to safely isolate before pulling the oven out.
Can I share a 32A circuit between oven and hob?
Yes — BS 7671 permits a combined cooker circuit serving both oven and induction or radiant hob through the same 32A radial, sized using the diversity calculation. For a 7.4 kW oven + 7.2 kW hob (14.6 kW total ≈ 63.5A connected): diversity = 10A + (53.5 × 0.3) = 26.05A. A 32A B-type MCB is adequate. Always check the manufacturer's instructions — some pyrolytic ovens require dedicated circuits.
Regulations & Standards
Building Regulations Part P (Approved Document P, 2013) — electrical safety in dwellings
Building Regulations Part J (Approved Document J, 2010+) — combustion appliances and fuel storage; gas oven flueing
BS 7671:2018+A2:2022 — Requirements for Electrical Installations (the IET Wiring Regulations)
Gas Safety (Installation and Use) Regulations 1998 (SI 1998/2451) — duty of competent gas work
IGEM/UP/1B — Tightness testing and direct purging of small natural gas installations
BS EN 60335-2-6 — Particular requirements for stationary cooking ranges (product standard)
BS EN 30 series — household gas-burning cooking appliances
hob installation pricing guide — companion appliance pricing
cooker hood installation pricing guide — kitchen install package
part p notifiable work — circuit notification decision
cable sizing cooker circuit — 6mm² T+E sizing and diversity