Summary

Data cabling is the job electricians get asked for on every rewire and every office refurbishment, and the one most often priced as "a bit of cable" and then lost money on. The cable is cheap; the termination, the testing and the paperwork are where the time goes, and a commercial client's IT contractor will reject a job that has not been tested to the standard. For a domestic job the issue is different: the customer sees a Wi-Fi router and does not understand why eight sockets cost £1,200.

This guide prices the job from the point count, covers the per-point and per-day build-ups for domestic and commercial work, the cable and hardware choices that move the price (Cat6 versus Cat6A, UTP versus shielded, external and fibre links), the testing levels and what each costs, and the standards a commercial client will ask about. For the technical choices (cable categories, separation from power, termination) see data cabling; for the AV and whole-home side see home networking for av.

The misconception is that a data point costs the same wherever it is. A point on a first-fix in an open-stud new build costs £60; the same point retrofitted through a finished house with a solid floor costs £200.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Item Domestic retrofit New build or first fix Commercial fit-out
First Cat6 point £90–£160 £70–£110 £75–£140
Additional Cat6 point £60–£110 £50–£80 £75–£140
Cat6A point £120–£220 £100–£150 £110–£200
Double outlet (two points, one plate) £130–£220 £110–£170 £130–£240
24-port patch panel terminated and labelled £180–£350 £180–£350 £200–£400
6U wall cabinet fixed with PDU and management £150–£300 £150–£300 £200–£400
12U cabinet £250–£450 £250–£450 £300–£600
Certification test and report, per link £6–£12 £5–£10 £4–£10
Wi-Fi access point cabled and mounted £140–£240 £110–£180 £130–£220
External run in duct, per metre £6–£12 £5–£10 £5–£10
Fibre link between buildings, up to 100 m £800–£1,800 £700–£1,500 £800–£2,000
Eight-point house with cabinet and panel £1,000–£1,800 £750–£1,300 —
50-point office with panels, cabinet and certification — — £4,500–£9,000

Detailed Guidance

Count the points, then look at the routes

A quote starts with a schedule: every outlet, its location, single or double, and where the cabinet will be. Then walk the routes. In a new build on first fix, the cables drop in the studs with the electrics and the price per point is the lowest. In a finished house, each point needs a route: up a cavity, through a floor void, behind a skirting, or in trunking; a solid ground floor and a loft above are the usual pair, and the cost is in the fishing and the making good. In an office, the routes are in the ceiling void and the dado trunking or floor boxes, and the number of points per route is high, so the price per point is between the two.

Two measurements matter: the longest run (it must be under 90 m, which rules out Cat6 for 10 Gigabit beyond 55 m) and the number of cables through the tightest containment (a 50 mm trunking takes about 25 Cat6 cables at a sensible fill; Cat6A is thicker and takes fewer).

Domestic pricing

Price the first point at £90–£160 and additional points at £60–£110, with the cabinet, patch panel and a switch or a router shelf as separate lines. A worked example for a four-bedroom house, retrofit, with a cabinet under the stairs: eight points (four bedrooms, living room TV wall, study, kitchen, loft for a Wi-Fi access point), two of them doubles, so ten cable runs. Cable 10 × 25 m average = 250 m at £0.60 = £150; modules and plates £70; 12-port patch panel £45; 6U cabinet with PDU £140; patch leads £30; sundries, trunking and fixings £40. Materials £475. Labour: two people, 1.5 days to run the cables (lofts, cavity drops, lifting boards, drilling through a solid floor), half a day to terminate, test and tidy: 2 days × £280 + 1.5 days × £150 = £785. Direct cost £1,260; at a 25% margin the price is £1,575, which is £950 for the points, £300 for the cabinet and panel, and the rest for the access point mounting and the making good. State that redecoration and filling behind trunking is excluded, and that the customer supplies the switch or router unless quoted.

Offer the 24-port panel even where 12 ports are needed: the price difference is £20 and the customer will add points.

Commercial pricing

Commercial clients buy data cabling by the point, with the containment often provided by the electrical contractor and the cabinet and active equipment by the IT contractor. Price per point for the cable, the outlet module in the client's chosen plate or floor box, the patch panel termination, the labelling to the client's schedule, and the certification test. A per-point rate of £75–£140 for Cat6 and £110–£200 for Cat6A is the market where the containment is in place and the points are in blocks; where the data installer also provides the containment, add it as a measured item (trunking at £15–£35 per metre fitted, basket tray at £20–£45 per metre).

A worked example for a 50-point office over one floor, Cat6A, containment by others: cable 50 × 40 m = 2,000 m at £1.10 = £2,200; shielded modules and plates £600; two 24-port Cat6A panels and a 12U cabinet £650; patch leads and labels £180. Materials £3,630. Labour: two people, 3 days to pull and dress, 1.5 days to terminate both ends and label, half a day to certify and produce the report: 5 days × (£300 + £160) = £2,300. Tester hire £300. Direct cost £6,230; at a 20% margin the price is £7,500, or £150 per point. That is at the upper end of the Cat6A band because of the certification and the cabinet; without the cabinet and with Cat6 it falls to around £105 per point.

Commercial clients also expect a 25-year system warranty where a single manufacturer's cable, modules and panels are used by an installer approved by that manufacturer. If the client asks for it, the manufacturer's approved-installer status is a precondition, and the components must all be from that manufacturer's range; price accordingly.

Testing and what to charge for it

Three levels. A wiremap test checks that each pair is connected pin to pin and there are no shorts or splits; the tester costs £30–£150 and the test takes a minute a point; it is the minimum for a domestic job and should be included in the point price. A qualification tester (£500–£1,500) checks whether the link will carry a given speed; it is useful for a domestic installer to prove a 1 Gigabit link but is not a certification. A certification tester (Fluke DSX-type, £5,000–£12,000, or hired at £80–£150 a day) measures the link against the BS EN 50173-1 class limits (Class E for Cat6, Class EA for Cat6A) and produces a pass/fail report per link with the measured parameters; it is what a commercial client's IT contractor wants, and the report is the hand-over document. Charge £4–£10 per link for certification, or build it into the commercial point price, and quote the tester hire where the job is too small to absorb it.

Standards and compliance

BS EN 50173-1 is the performance standard: it defines the channel and permanent link classes that the cable categories deliver. BS EN 50174-2 is the installation standard inside buildings: separation from power, bend radius, cable support, pulling tension and segregation in containment. BS 6701:2016+A1:2017 is the UK code of practice for telecommunications installation and includes the UK-specific requirements for the installation of cabling and the bonding of screened systems. BS 7671:2018+A2:2022 governs any shared containment with mains cables (Band I and Band II circuits must be separated or the data cable insulated to the higher voltage) and any power circuit the installer adds for the cabinet. On a commercial fit-out the client's specification will cite these, and the test report should state the class tested against.

Data cabling is not notifiable under Part P; a power circuit for the cabinet is.

What changes the price

Frequently Asked Questions

Should I quote Cat6 or Cat6A?

For a house, Cat6 carries 1 Gigabit to the full 90 m and 10 Gigabit to 55 m, which covers almost every domestic run, and it is cheaper, thinner and easier to terminate; quote Cat6 unless the customer asks for Cat6A or the runs will carry 10 Gigabit over 55 m. For a commercial fit-out, Cat6A is now the default specification because it carries 10 Gigabit to the full length and supports the higher power levels of PoE access points and cameras without the heating issues of thinner cable; quote Cat6A and offer Cat6 as a saving if the client asks.

Does data cabling need an electrician?

No. Data cabling is extra-low-voltage work outside Part P, and many installers are not electricians. It does need to follow BS EN 50174-2 and BS 6701 for separation from mains and for containment, and any power circuit added for the cabinet or an external access point is electrical work under BS 7671 that must be done by a competent person and, if notifiable, by a registered electrician. On a rewire the electrician usually runs the data with the power at first fix and the price per point is at its lowest.

Why does a commercial job need certification rather than a simple test?

A wiremap test proves the pins are connected; it does not prove the link will carry the speed the client is paying for. Certification measures the link against the class limits in BS EN 50173-1 (attenuation, crosstalk, return loss and the rest) and produces a report per link; the IT contractor installs the switches on the strength of it, and a manufacturer's 25-year warranty depends on it. A commercial client who has paid for Cat6A and gets a wiremap print-out has not received what they bought.

How many points does a house need?

Two at the TV wall (TV and a streaming box or console), one in each bedroom, one in a study or wherever someone works, one in the kitchen for a smart display or a second TV, and one or two in the ceiling (landing and a central ground-floor position) for Wi-Fi access points; eight to ten for a three- or four-bedroom house. Quote the ceiling points even if the customer does not ask; the reason for cabling a house is to put the Wi-Fi where it is needed, and a cabled access point is the fix for every "the Wi-Fi is bad upstairs" call.

Regulations & Standards