squote
Knowledge
Home
Login
Try free →
← Knowledge Base
Insulation
25 articles
Airtightness Testing UK: Where Leaks Happen & How to Seal
Airtightness and blower door testing: air permeability targets, common leakage paths, membrane installation, smoke testing
Breathable Membranes: HR vs LR Grade Selection Guide UK
Cavity Wall Insulation Problems: When CWI Goes Wrong UK
Cavity wall insulation: blown fibre, EPS bead, PUR foam; when cavities are unsuitable, remediation for failed installations
Cavity Wall Insulation Types: Mineral Wool vs EPS vs PIR
Mineral wool vs EPS bead vs phenolic full-fill board; λ values; exposure-zone suitability (driven rain); retrofit injection vs new-build batts; Part L target U-values; PAS 2035; complements u-value-calculator
EPC Ratings Explained: A–G Bands & How to Improve UK
EPC ratings A–G explained: SAP calculation method, band thresholds, improvement measures, minimum E for landlords (MEES)
External Wall Insulation: UK Building Regs & Install Guide
EPS/mineral wool/phenolic EWI: U-value targets (0.30 W/m²K existing), PAS 2030/2035 for funded work, fire performance over 18m, SWIGA/CIGA guarantees, detailing at openings
Floor Insulation UK: Suspended Timber & Solid Concrete Guide
Floor insulation: suspended timber (100mm mineral wool), solid concrete (PIR boards), compatibility with wet UFH systems
Insulation Board Types: PIR, EPS, Mineral Wool
UK rigid insulation: PIR 0.020–0.023 W/m·K Euroclass F; phenolic 0.018–0.021 W/m·K; EPS 0.030–0.038 W/m·K Euroclass E; mineral wool 0.032–0.044 W/m·K Euroclass A1/A2; XPS for below DPC; selection by Part B/L
Interstitial Condensation: Prevention Guide UK
Loft Insulation Depth UK: Part L Requirements & Materials
Loft insulation: 270mm mineral wool target, cold roof ventilation (1:150 ventilation ratio), Approved Document L requirements
Loft Insulation Types UK: Mineral Wool vs Foam Guide 2024
Mineral wool 270-300mm to 0.16 W/m²K; blown cellulose; spray foam (open/closed cell) and mortgage-lending caveat; cold vs warm loft; ventilation to avoid condensation; ECO4/GBIS grants; PAS 2035
MVHR Installation Guide: Heat Recovery Ventilation & Part F
MVHR installation: Part F 2021 System 4, ≥85% heat recovery new build, ducting sizing and routing, balanced commissioning ±10%, F7/G4 filter classes, summer bypass, SFP ≤0.8 W/(L/s); SAP Appendix Q certification
Natural Insulation Materials UK: Types & When to Use
Sheepswool, hemp fibre, wood fibre, cellulose, cork compared: lambda values, vapour-open vs vapour-closed, fire performance, breathable construction compatibility
Pipe Insulation Thickness UK: BS 5422 Compliance Guide
Part L1B pipe insulation tables, BS 5422:2009, frost protection in unheated spaces, vapour barrier on chilled pipes, material types (mineral wool, foam, phenolic)
Rigid Insulation Board Guide: PIR vs EPS vs XPS vs Phenolic
PIR (~0.022), EPS (~0.032), XPS (~0.034), phenolic (~0.020 W/m·K) compared: compressive strength, moisture resistance, fire performance, applications and BBA certificates
Secondary Glazing UK: U-Values, Listed Buildings & Retrofit
Internal pane, original window kept; ~1.7-2.0 U-value, up to ~45-50dB acoustic (wider gap = better); thermal gap ~20mm, acoustic 100-200mm; PD but listed building consent may still apply; Historic England favours it
Solid Wall Insulation UK: Internal vs External Guide
Solid wall insulation: IWI vs EWI; vapour control layers, cold bridging at reveals, planning considerations for EWI
Spray Foam Insulation and Mortgage Problems: What Lenders Say
Spray foam (esp. closed-cell to roof underside) causing mortgage/remortgage/equity-release refusals; not banned but a valuation/survey red flag; open vs closed cell, removal £1.5-4.5k; RICS, PAS 2035
Structural Insulated Panels (SIPs): U-Values & UK Guide
Thermal Bridging: What It Is & How to Fix It UK
Thermal bridging: linear and point bridges, psi values, party wall junction, window reveal details, Approved Document L
Vapour Control Layers: Sd Values & Positioning BS EN ISO 13788
Sd values (barrier ≥100m, VCL 2-100m, breathable ≤0.3m); warm-side-tight/cold-side-open ~5:1; no double barrier; BS 5250 / BS EN ISO 13788 Glaser; intelligent VCLs for retrofit; sealed laps/AVCL
Ventilation Strategy Part F: Natural, MEV, dMEV & MVHR
Ventilation strategies: natural, dMEV, MEV, and MVHR — Part F 2021 flow rates, commissioning requirements
Warm Roof vs Cold Roof: Which to Specify? BS 6229
Cold roof (insulation at ceiling, 50mm ventilated void) vs warm roof (insulation above deck), BS 6229, 1:150 ventilation ratio, condensation risk, Part L compliance
What Are the Options and Risks of Internal Wall Insulation?
IWI types (PIR, stud frame, cork, woodfibre), condensation risk at joist ends, VCL requirements, planning implications, PAS 2035 High Risk classification
What Are the Risks of Spray Foam Insulation in Roofs?
Mortgage lending problems (RICS/UK Finance guidance), removal costs (£1,500–£4,500), vapour permeability loss, closed-cell vs open-cell differences, Ofgem ECO scheme complaints