Summary
A uPVC window that was fine for fifteen years and now has to be lifted and shoved to close is the most common window call-out there is, and the customer has often been told it needs a new window. It almost never does. The sash is a frame of hollow plastic profile held square by the sealed glass unit inside it; the unit sits on packers at the bottom corner on the hinge side and the top corner on the handle side (toe-and-heel packing), and the whole thing hangs on two friction stays. Over the years the stays wear, the packers drop or were never fitted, the profile creeps, and the sash sags at the handle side until it fouls the frame and the locking cams miss their keeps.
Diagnosing it is a matter of looking at the gaps and watching the cams. The fix is adjusting or replacing the stays, re-packing the glass so it holds the sash square, and occasionally moving or replacing keeps. A new gearbox or a new handle is a separate fault and the handle-first repair that many customers have already tried does nothing for a dropped sash. This guide gives the diagnosis sequence, the adjustments on the common hinge types, the toe-and-heel method, lock and gearbox faults, and when a window really is beyond repair. For hardware identification see upvc window hinge and handle replacement; for the general repair picture see upvc window repair.
Key Facts
- Friction stays — the stainless steel sliding-arm hinges top and bottom of a side-hung sash, or either side of a top-hung sash; the sash's full weight hangs on them when open. Standard, egress (fire escape, opens to 90° and clear) and restricted (child-safe, 100 mm) types; 12 and 16 mm stack heights, 200–600 mm lengths matched to sash size and weight
- Stay wear — the sliding shoe and the pivot rivets wear; a worn stay lets the sash drop at the handle side and rattle when open. Life 10–20 years, less on large or coastal windows
- Adjustable stays — most stays fitted since the mid-2000s have an adjuster (a small screw on the track, or an eccentric cam) that moves the sash 1–2 mm; older stays have none and the sash is set by the packers
- Toe-and-heel packing — the glass unit is packed with glazing packers (plastic, 1–6 mm, 28 mm wide) at the bottom hinge-side corner and the top handle-side corner on a side-hung casement, so the rigid unit holds the flexible sash square and lifts the handle side. Missing or slipped packers are the root cause of most dropped sashes
- Gap check — a correctly hung sash has an even 3–5 mm gap all round; the drop is visible as a wider gap at the top of the handle side and a scuffed, tight bottom corner
- Espagnolette — the lock strip in the sash edge, driven by the handle through a gearbox; mushroom-headed cams (or roller cams on older locks) rotate behind keeps screwed to the frame. Cams that miss the keeps by 2 mm will not lock; cams that clip the keep edge make the handle stiff
- Keeps — adjustable on most systems by slackening the screw and sliding the keep; a keep moved 2–3 mm often fixes a lock that "nearly" engages
- Gearbox — the handle spindle turns the gearbox; a stripped gearbox lets the handle turn freely without moving the cams; replacement gearboxes are matched by backset (usually 20–22 mm) and fixing centres
- Handle — spindle lengths and backplate screw centres (43 mm is common) vary; a wrong spindle length means the handle will not drive the gearbox fully
- Gaskets — a hard, shrunk or displaced wedge gasket can hold the sash off the frame by 1–2 mm and stop the cams reaching; also the cause of draughts
- Profile creep and heat — dark-coloured foiled sashes on south-facing elevations expand on hot days and bind at the top; a window that only sticks in summer is thermal, and the clearance is adjusted on a hot day
- Frame movement — a frame that has bowed because the fixings have failed or the packers under the sill have dropped shows as a sash that binds at one point only and a cracked bead of sealant outside; the fix is the frame, not the sash
- Escape windows — bedroom and inner-room windows that are the means of escape must open to at least 0.33 m² with no dimension less than 450 mm (Approved Document B, Volume 1); do not fit a restrictor or a non-egress stay to one
- Sash weight — a 1,200 × 600 mm sash with a 28 mm double-glazed unit weighs about 25 kg; stays are rated by sash weight and size and an under-rated stay wears fast
- Time on site — gap check and hinge adjustment 15–30 minutes; stay replacement 30–45 minutes per sash; toe-and-heel repack 20–40 minutes; gearbox replacement 30–60 minutes
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Symptom | Likely cause | Confirm | Fix |
|---|---|---|---|
| Sash catches at bottom handle-side corner; gap wide at top | Dropped sash: worn stays or missing packers | Even-gap check; lift the sash by the handle and feel the play | Adjust stays; toe-and-heel repack; new stays |
| Handle turns but will not go to the locked position | Cams misaligned with keeps | Watch cams against keeps with the sash open | Adjust keeps; correct the sash drop |
| Handle turns freely, nothing moves | Gearbox stripped or spindle sheared | Remove the handle, turn the spindle with pliers | New gearbox or spindle |
| Handle stiff, needs forcing | Cams clipping keep edges; dry lock; sash binding | Lubricate; check gaps | Adjust keeps; silicone spray; re-align sash |
| Sash will not close at the top only | Top stay worn, or thermal expansion | Check in cool conditions; measure gap | Adjust top stay; ease the clearance |
| Window rattles when open and drops when opened wide | Friction stays worn | Open to 45°, lift the sash, feel the play | Replace the stays |
| Locks but draughty; sash sits off the frame | Gasket displaced or hardened | Inspect the wedge gasket | Replace the gasket |
| Sash binds at one point; sealant cracked outside | Frame bowed or fixings failed | Straightedge on the frame | Re-fix and pack the frame |
| Will not close after a glass unit was replaced | Glazier did not toe-and-heel | Gap check | Repack the new unit |
Detailed Guidance
Diagnostic sequence
uPVC CASEMENT WILL NOT CLOSE OR LOCK
│
├─ Close the sash gently. Is the gap even (3–5 mm) all round?
│ ├─ No: wide at top handle side, tight at bottom ──► DROPPED SASH
│ │ ├─ Open to 45°, lift the sash by the handle: play at the stays?
│ │ │ ├─ Yes ──► worn stays: adjust if adjustable, else replace
│ │ │ └─ No ───► packing: de-glaze and toe-and-heel
│ │ └─ After correction, re-check the cams against the keeps
│ ├─ No: binds at one point, sealant cracked outside ──► FRAME MOVEMENT
│ └─ Yes, gap even ──► continue
│
├─ Open the sash. Turn the handle and watch the cams.
│ ├─ Cams move but miss or clip the keeps ──► ADJUST KEEPS
│ ├─ Cams do not move; handle turns freely ──► GEARBOX / SPINDLE
│ ├─ Cams move but handle very stiff ──► lubricate; check for a bent strip
│ └─ Cams and keeps line up ──► continue
│
├─ Sash closes but will not pull tight; draughty?
│ └─ GASKET hardened or displaced ──► replace the gasket
│
└─ Only sticks on hot sunny days? ──► THERMAL: ease clearance on a warm day; check gaskets
Reading the gaps
Stand inside, close the sash without forcing it, and look at the shadow gap between the sash and the frame all the way round. It should be the same width everywhere, 3–5 mm on most systems. A side-hung casement that has dropped shows a wider gap along the top on the handle side, closing to nothing at the bottom handle-side corner, where the sash's outer face will be scuffed from hitting the frame. A top-hung sash that has dropped shows the gap wider at the top and the sash sitting low on both sides.
Then open the sash to about 45°, take the handle and lift. A sash on sound stays and sound packing lifts a millimetre or less and feels solid; one on worn stays lifts 3–5 mm and you can feel the shoe moving in the track. If the stays are solid but the sash still sits low when closed, the fault is inside the sash: the glass unit is not holding it square.
Adjusting and replacing friction stays
Modern stays carry an adjuster. On many it is a small cross-head or Torx screw in the track near the sash end of the arm; a quarter-turn moves the sash about half a millimetre. Others use an eccentric cam at the pivot. Adjust the bottom stay to lift the handle side, re-check the gap, then adjust the top stay so the sash runs parallel to the frame. Stays with no adjuster are set by the packing.
Replacing stays: open the sash to 90°, support it (a second pair of hands on a big sash), undo the screws holding the stay to the sash first and then to the frame, and lift the sash out. Measure the stay's length, stack height (12 or 16 mm) and whether it is a standard, egress or restricted type. Fit the new stays to the frame first, then offer up the sash and screw it to the stays using the existing holes where they are sound and new holes 10 mm along where they are stripped. Egress stays must go back on escape windows; a restricted stay on a bedroom window is a fire-safety defect. Sizing is by sash width and weight from the maker's table; an under-rated stay on a 25 kg sash will drop again within two years. See upvc window hinge and handle replacement.
Toe-and-heel packing
If the stays are sound and the sash still sags, de-glaze it. On a uPVC casement the beads are on the inside: start on a long bead in the middle with a glazing shovel or a stiff putty knife, work it out, then the short beads. Note where the packers are. On a side-hung casement they should be at the bottom corner on the hinge side (the heel) and the top corner on the handle side (the toe), with the unit also packed at the other corners for support but not loaded there. The idea is that the rigid glass unit, braced diagonally, carries the handle side up.
With the sash open and supported, add packers at the toe until the sash lifts to an even gap when closed, and at the heel to stop the unit sliding. Packers go under the unit's edge, not against the spacer bar face, and must sit on the glazing bridge so they do not block the drainage slots. Refit the beads, short ones first, tapping them home with a nylon mallet. A unit replaced by a glazier who did not toe-and-heel is a common reason a window stops closing a month after a new pane. See double glazed unit replacement guide.
Locks, keeps and gearboxes
With the sash hanging square, open it and turn the handle to the locked position while watching the cams. They should rotate clear of the keeps and, with the sash closed, sit behind them and pull the sash onto the gaskets. Keeps that the cams miss by a couple of millimetres are slackened and slid up or down; keeps the cams clip are moved out or the cam's eccentric adjusted (mushroom cams on most modern strips have a hex or slot adjuster for compression). Lubricate the strip with a silicone spray or a light machine oil once a year.
A handle that turns without moving the cams has a stripped gearbox or a sheared spindle. Remove the handle, put pliers on the spindle and turn; if the cams move, it is the handle or the spindle, and if they do not, it is the gearbox. Gearboxes are replaced by unscrewing the strip from the sash edge, sliding it out, swapping the gearbox section (matched on backset and the fixing centres) and refitting. A bent strip from a forced close is replaced whole. See upvc window repair.
Gaskets, weather and the frame
A wedge gasket that has shrunk and pulled out of the corners lets the sash sit proud and cold air in; pulling it out and fitting new gasket from a coil is a 30-minute job per sash. A sash that only binds in hot weather is thermal: dark foiled profiles expand several millimetres over a 2 m sash, and the clearance has to be set on a warm day so that it still closes.
A frame that has bowed inwards at mid-height, with a cracked sealant line outside and a sash that catches only at one point, has lost its fixings or its packers. Frames should be fixed at 150 mm from each corner and at 600 mm centres, packed at the fixings; a long frame fixed only at the corners bows under the sash's weight. The fix is re-fixing and packing the frame, not more hinge adjustment. See upvc window installation guide.
Pricing
| Job | Time | Typical charge (2026) |
|---|---|---|
| Diagnosis, hinge adjustment and lubrication, one window | 20–30 min | £60–£100 |
| Friction stay replacement, per sash (parts £8–£25) | 30–45 min | £80–£140 |
| Toe-and-heel repack, per sash | 20–40 min | £70–£120 |
| Keep adjustment and lock service | 15–30 min | £50–£90 |
| Gearbox replacement (parts £15–£40) | 30–60 min | £90–£160 |
| Full espagnolette strip | 45–60 min | £110–£190 |
| Gasket replacement, per sash | 30–45 min | £60–£110 |
| Re-fix and pack a bowed frame | 1–2 h | £120–£220 |
A window company's call-out is usually a half-day minimum of £120–£200; a multi-window visit brings the per-window figure down. For a window the customer has been told needs replacing, the comparison with window replacement pricing guide usually ends the conversation.
Frequently Asked Questions
Does a dropped sash mean the window needs replacing?
Rarely. A dropped sash is a hardware and packing fault in a frame that is otherwise sound, and the parts cost less than £30. A window is replaced when the frame itself has failed (bowed, cracked welds, rotten timber subframe), the profile has gone brittle and yellow, or the sealed units have failed and the customer wants the thermal upgrade at the same time. Fix the sash and let the customer decide about the glass separately.
Can I just fit a new handle?
A new handle fixes a broken handle, a stripped handle square or a wrong spindle. It does nothing for a dropped sash or misaligned keeps, which is why the customer who already tried it is calling you. Diagnose the alignment first; if the handle turns the cams fully, the handle is fine.
How do I know which friction stays to buy?
Measure the old stay's length (track length, usually 200–600 mm), its stack height (12 or 16 mm, measured with the stay closed), and whether it is standard, egress or restricted. Weigh or estimate the sash (about 20 kg per square metre of 28 mm double glazing plus the frame) and check it is within the stay's rating. Buy stainless steel; mild-steel stays rust at the rivets within a few years.
The window locks but is draughty and whistles. Is that the same problem?
Usually not. A sash that locks but does not compress onto the gaskets has either shrunk, hardened gaskets or cams that need their compression adjusted. Replace the gasket if it has pulled out of the corners or has gone hard; otherwise adjust the mushroom cams a quarter-turn to pull the sash tighter. A sash that has dropped will often be draughty at the top handle side as well, so do the gap check first.
Is there anything I should not do to an escape window?
Do not fit restricted stays, a lockable restrictor without a key left in the room, or a sash-stop that limits the opening, and do not replace egress stays with standard ones. A bedroom window that is the means of escape must open to the 0.33 m² and 450 mm figures in Approved Document B. Child-restrictors that release for cleaning and escape are acceptable.
Regulations & Standards
Building Regulations 2010, Approved Document B, Volume 1 — means of escape; emergency egress windows (0.33 m² clear opening, minimum 450 mm height and width, sill not more than 1,100 mm above floor)
BS 6375-2:2009 — performance of windows and doors; classification for operation and strength, and guidance on selection and specification
BS EN 13126-6:2018 — building hardware; hardware for windows and door height windows, requirements and test methods, Part 6: variable geometry stay hinges (with or without a friction system), i.e. friction stays
BS EN 13126-3:2023 — building hardware; hardware for windows and door height windows, Part 3: handles, primarily for tilt and turn, tilt-first and turn-only hardware
BS 8213-4:2016 — windows and doors; code of practice for the survey and installation of windows and external doorsets
BS EN 12608-1:2016+A1:2020 — unplasticised polyvinyl chloride (PVC-U) profiles for the fabrication of windows and doors
BS EN 1279 series — glass in building; insulating glass units
PAS 24:2022 — enhanced security performance requirements for doorsets and windows; relevant where hardware is replaced on a window that was specified to it
Building Regulations 2010, Approved Document Q — security in dwellings; applies to replacement windows in new dwellings
Approved Document B, Volume 1 — GOV.UK — escape window dimensions
Glass and Glazing Federation — technical guidance — toe-and-heel glazing and window installation good practice
BS 8213-4:2016 — BSI — survey and installation of windows
Friction stay selection and fitting — Securistyle technical data — stay sizes, stack heights and sash weight ratings
Window hardware standards — BS EN 13126-6 — BSI — friction stay (variable geometry stay hinge) requirements and test methods
upvc window hinge and handle replacement — identifying and replacing stays and handles
upvc window repair — the repairable faults on uPVC windows
double glazed unit replacement guide — replacing a unit and packing it correctly
upvc window installation guide — frame fixing and packing
draught proofing — gaskets and seals