Summary
The internal stopcock is the valve nobody touches until the day they need it, and that is the day it will not move. A screw-down stopcock relies on a brass spindle turning in a packed gland; in hard water the spindle scales, the packing hardens around it, and after ten years without a turn the handle will not budge. The customer finds out when a pipe bursts, a tap fails, or a plumber arrives to fit a new kitchen and cannot isolate. The second complaint, a drip from the stopcock, usually arrives the week after someone did finally turn it, because the gland packing that held while the spindle was still lets water past once it moves.
Both faults are routine, but both go wrong when forced. A plumber's wrench on a seized handle shears the spindle or splits the body, and now the mains is running into the kitchen cupboard with no way to stop it except the outside stop tap, which may also be seized. The right sequence is gentle, patient, and has the isolation plan ready before anything is touched. This guide gives the diagnosis for a stuck valve and a leaking one, the freeing technique and its limits, the gland repack, the replacement options and how to isolate for each, and what to tell a customer about the valve the Water Regulations say they must have. For valve types see stopcock types; for pricing see stopcock replacement pricing guide.
Key Facts
- Legal requirement — every premises must have a stop valve to isolate the internal supply, as close as reasonably practicable to the point where the service pipe enters the building (Water Supply (Water Fittings) Regulations 1999, Schedule 2, paragraph 10); a stopcock that does not work is a defect the water company can require to be fixed
- BS 1010 stopcock — the traditional screw-down pattern with a crutch head, a brass spindle, a jumper and washer, and a packed gland; closes clockwise. Series A for 15 mm and 22 mm domestic service pipes
- Lever valve to BS EN 13828 — quarter-turn full-bore ball valve; does not seize, no gland to repack, but a handle knocked in a cupboard shuts the water off, and a cheap one can seize in the open position. The replacement of choice on copper and MDPE
- Direction of flow — the arrow on a screw-down stopcock body must point in the direction of flow; fitted backwards it still closes but the washer sits on the wrong side of the seat and the gland sees mains pressure when shut
- Gland nut — the hexagonal nut directly under the handle; a leak here is gland packing. Tightening a quarter-turn often stops it; repacking with PTFE string or graphite packing is the proper fix
- Bonnet joint — the large nut where the bonnet screws into the body, sealed with a fibre washer; leaks here after the valve has been disturbed or overtightened
- Compression joints — the 15 mm or 22 mm nuts either side; a leak at an olive, especially on an old valve that has been knocked
- Jumper and washer — the valve washer at the bottom of the spindle; a worn washer means the stopcock will not shut off fully (water still runs at the taps), not a leak outside the valve
- Seized spindle — scale and hardened packing; the handle will not turn in either direction. Never use a wrench on the handle or heat on a valve near a plastic or lead pipe
- Penetrating oil method — oil the spindle at the gland, wait 30–60 minutes, back off the gland nut a quarter-turn to relieve the packing, work the handle gently both ways, repeat; most spindles free in an hour, some never will
- Lead pipe — a stopcock on a lead service pipe (pre-1970 houses) sits on a wiped joint or a lead-to-copper adaptor; do not freeze lead, do not put a wrench on it, and plan for the water company's stop tap or a lead-to-MDPE replacement
- Outside stop tap — the water company's valve at the boundary, usually under a small cover 600–1,000 mm down; operated with a stop tap key. It belongs to the water company; if it is seized the company will attend to operate or replace it, often free, but on their timescale
- Pipe freezing — a freeze kit freezes an ice plug in the copper 300–500 mm upstream for 20–40 minutes of working time; only on copper or plastic, never lead, and never with the water flowing
- Half-open rule — screw-down stopcocks are left a quarter to half-turn back from fully open so the spindle does not seize at the top of its thread; a lever valve is left fully open
- Drain-off — a drain cock should be fitted immediately after the stopcock so the rising main can be drained; many houses have none
- Time on site — free a seized spindle 30–90 minutes; repack a gland 20–30 minutes; replace with isolation at the boundary 45–90 minutes; replace with a freeze kit 60–120 minutes
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Symptom | Cause | Check | Action |
|---|---|---|---|
| Handle will not turn either way | Spindle seized in packing and scale | Gentle pressure only; look for a bent spindle or cracked body | Penetrating oil and patience; replace if it does not free |
| Handle turns but water still runs at the taps | Washer or jumper worn, or seat scored | Shut fully; open a kitchen tap | New washer and jumper, or new valve |
| Drip from under the handle | Gland packing worn | Tissue under the gland nut | Tighten gland nut a quarter-turn; repack |
| Weep from the large nut below the gland | Bonnet fibre washer | Tissue on the bonnet joint | Isolate, remove bonnet, new washer |
| Weep from a compression nut | Olive not sealing; pipe moved | Tissue on each nut | Isolate, re-make with a new olive |
| Handle turns freely but nothing happens | Spindle sheared or handle stripped | Remove handle; try the spindle with pliers | New valve |
| Valve weeps only when shut | Gland on the pressure side (valve fitted backwards) | Arrow direction on body | Refit the right way round or replace with a lever valve |
| Water hammer when closing | Fast-closing lever valve on a long run | Listen as it closes | Close slowly; fit an arrestor if persistent |
Detailed Guidance
Diagnostic sequence
STOPCOCK PROBLEM
│
├─ WILL NOT TURN
│ ├─ Spindle visibly bent or body cracked? ──► REPLACE (plan isolation first)
│ ├─ Handle loose on a square spindle? ──► fit a new handle or pliers on the spindle
│ └─ Handle solid on spindle, spindle solid in gland
│ └─ Oil, wait, back off gland nut ¼ turn, work gently both ways
│ ├─ Frees ──► work fully open and shut 3 times, re-tighten gland, leave ½ turn off full open
│ └─ Still seized after 60–90 min ──► REPLACE
│
├─ LEAKING
│ ├─ Under the handle ────────► GLAND: tighten ¼ turn; if still weeping, repack
│ ├─ At the bonnet nut ───────► BONNET WASHER: isolate, new fibre washer
│ ├─ At a compression nut ────► OLIVE: isolate, re-make with new olive
│ └─ From a crack in the body ► REPLACE now; isolate at the boundary
│
└─ WILL NOT SHUT OFF
└─ Washer/jumper worn or seat scored ──► isolate at the boundary, new jumper; or replace
Before touching a seized stopcock: have the isolation plan
Find the outside stop tap and test it before working on the inside valve. Lift the cover at the boundary (a small cast or plastic lid in the pavement or the front garden), clear the chamber of soil, and use a stop tap key to close it gently; then open a tap inside and confirm the flow stops. If the outside tap works, you have a safe fallback and the inside valve can be freed or replaced without a freeze kit. If it is seized, buried or missing, telephone the water company to attend, or plan to freeze. Never start on a seized inside valve with no way to stop the water if it breaks.
Check what the stopcock is connected to. A lead rising main, a 1960s galvanised steel pipe or a plastic pipe each rules something out: no wrench or heat on lead, no freezing on lead, and no soldering near plastic.
Freeing a seized stopcock
Work the handle only by hand. Spray penetrating oil where the spindle enters the gland nut and leave it for thirty minutes. Back the gland nut off a quarter-turn with a spanner, which eases the packing's grip on the spindle, and try the handle again with steady pressure in the closing direction, then the opening direction, never a jerk. A spindle that gives a degree or two will usually free in a few more minutes of back-and-forth; one that gives nothing after an hour of oil and patience is not going to, and the valve is replaced.
Once it moves, work it slowly through its full travel three times to clear the scale from the thread, tighten the gland nut until the weeping stops, and leave the valve half a turn back from fully open. Show the customer the position and tell them to turn it fully off and on twice a year; the Water Regulations put the working valve on the owner, and a valve that is exercised does not seize.
Repacking the gland
A drip from under the handle after the valve has been used is the packing. With the valve open (so the spindle's back-seat takes the pressure on many patterns) or the supply isolated, remove the handle screw and the handle, undo the gland nut and slide it up the spindle, pick out the old packing with a small screwdriver, and wind in three or four turns of PTFE packing string or graphite packing in the direction the gland nut tightens. Refit the gland nut finger-tight plus a quarter-turn, refit the handle, open and close the valve, and tighten the gland a little further if it still weeps. A gland tightened until the spindle is stiff will seize again within a year; the packing should seal with the spindle still free.
Replacing the stopcock
The choices are a like-for-like BS 1010 screw-down valve or a full-bore quarter-turn lever valve. The lever valve does not seize, has no packing to fail, and gives a full bore (better for flow to a combi), but it can be knocked shut in a cupboard, and the fast close can cause water hammer on a long rising main. Most plumbers fit a lever valve on copper and MDPE and a BS 1010 where the customer prefers the familiar handle or the pipe is awkward. Either way, fit a drain cock immediately after it if there is not one.
Isolation options:
| Method | When | Notes |
|---|---|---|
| Outside stop tap | It works and is accessible | Open the kitchen tap to drain the main; expect a dribble from the pipe; have a bowl ready |
| Water company attendance | Outside tap seized, buried or missing | Often free; days of lead time; they will not work inside the property |
| Pipe freezing kit | Copper or plastic pipe, outside tap unusable, job must be done today | Freeze 300–500 mm upstream, 15–20 minutes to form the plug, 20–40 minutes working time; keep the pipe still and water off; never on lead |
| Branch-insertion clamp or live-pressure replacement tool | Copper, where a freeze is impractical | Specialist kit; only with training |
Cut out the old valve with pipe slices rather than a hacksaw so the ends are square, deburr, fit the new valve with the arrow in the direction of flow (on a BS 1010; a lever valve is bidirectional), new olives, and support the pipe either side so the valve is not carrying the pipe's weight. Open the supply slowly with a tap open to purge the air, then test every joint with a dry tissue. On a lead service pipe, the sensible replacement is a lead-to-MDPE adaptor outside and a new rising main to a new stopcock inside, which is a bigger job and a lead-removal conversation; see mains water connection.
Pricing and the conversation with the customer
| Job | Time | Typical charge (2026) |
|---|---|---|
| Free a seized stopcock, exercise and repack | 45–90 min | £90–£160 |
| Repack the gland only | 20–30 min | £70–£120 (half-day minimum usually applies) |
| Bonnet washer or jumper and washer | 30–45 min | £90–£150 |
| Replace with a lever valve, boundary isolation | 45–90 min | £120–£220 |
| Replace with a lever valve, freeze kit | 60–120 min | £160–£280 |
| Add a drain cock while the valve is off | +15 min | +£25–£45 |
Make the quote conditional on the isolation method and say so in writing: "Price assumes the external stop tap can be operated; if not, pipe freezing adds £40–£60 or we wait for the water company." A stopcock seized solid is the common reason a bigger job (a new bathroom, a boiler) stalls on day one, so check it at the survey, not on the morning. See stopcock replacement pricing guide and isolation valves.
Frequently Asked Questions
Can I use a wrench or a spanner on a seized stopcock handle?
No. The handle is cast brass on a brass spindle; a wrench either strips the handle's square, shears the spindle at the gland, or cracks the body at the bonnet thread, and any of those on a live mains with no outside isolation is a flood. Hand pressure, penetrating oil and time, or replacement with a plan to isolate, are the options.
The stopcock turns but the water does not stop. Is it broken?
Not necessarily. The washer on the jumper is worn, or scale has lodged on the seat, so the valve closes but passes water. Isolate at the boundary, remove the bonnet, fit a new washer and jumper (the standard BS 1010 pattern uses a 15 mm or 22 mm tap washer on a loose jumper), clean the seat, and refit. If the seat is scored, replace the valve. Until it is fixed the customer has no working isolation, which matters more than the drip.
Is it legal to leave a non-working stopcock?
The Water Supply (Water Fittings) Regulations 1999 require a stop valve that the occupier can use to shut off the supply, and a seized valve does not meet that. In practice enforcement comes when the water company inspects, or when an insurer looks at a burst-pipe claim where the water could not be shut off. Fixing it is cheap; the claim is not.
Why is the stopcock leaking only when it is turned off?
On a BS 1010 valve fitted the right way, the mains pressure sits below the washer when the valve is shut, so the gland sees no pressure. Fitted backwards, with the arrow against the flow, the gland is on the pressure side when the valve is shut and a worn packing weeps. It will also close less well because the pressure is lifting the washer. Refit it the right way round or replace it with a lever valve.
Should I replace a working screw-down stopcock with a lever valve anyway?
If it is being disturbed for other work, or it is over 25 years old, yes: a lever valve on a new pair of olives removes the seizing problem and gives the customer a valve they can operate with one hand. If it works, is exercised and does not leak, leave it and show the customer how to turn it.
Regulations & Standards
Water Supply (Water Fittings) Regulations 1999, Schedule 2, paragraph 10 — stop valve required inside every premises as close as reasonably practicable to the point of entry; drain tap requirement
Water Industry Act 1991 — the water undertaker's ownership of the external stop tap and service pipe to the boundary
BS 1010-2:1973 — draw-off taps and stopvalves for water services (screw-down pattern); stopvalves
BS EN 13828:2003 — building valves; manually operated copper alloy and stainless steel ball valves for potable water supply in buildings
BS EN 1254-2:2021 — copper and copper alloys; plumbing fittings, compression fittings for copper tubes
BS EN 806-2:2005 — specifications for installations inside buildings conveying water for human consumption; design
BS 8558:2015 — guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings
Water Regulations Approval Scheme (WRAS) — approved valves and fittings for mains water
Control of Lead at Work Regulations 2002 — handling lead pipe during replacement
Water Supply (Water Fittings) Regulations 1999 — legislation.gov.uk — Schedule 2 stop valve requirements
Water fittings regulations guidance — WRAS — approved stopvalves and householder duties
Find and use your stop tap — Water UK — customer and company responsibilities for internal and external stop taps
Lead pipes — Drinking Water Inspectorate — lead service pipe replacement guidance
Pipe freezing kits — guidance for plumbers — CIPHE — safe use of freeze kits on copper
stopcock types — BS 1010, gate valves and lever valves compared
stopcock replacement pricing guide — pricing by isolation method
isolation valves — service valves on appliances and fittings
burst pipe — when the stopcock is needed in a hurry
low mains water pressure — a part-closed or scaled stopcock as a cause of low flow
mains water connection — lead-to-MDPE rising main replacement