Summary
Laminate is cheap to lay and expensive to lay badly, because the faults do not appear on the day. A floor laid in October with the skirting nailed down tight over it looks fine until June, when the planks have taken on moisture, grown 5 mm across a 4 m room and have nowhere to go, and a ridge appears across the middle. A floor laid over a slab that was not flat looks fine until the family has walked on it for six months and the joints over the hollows have worked loose and started to click and gap. The customer blames the laminate; the laminate is usually fine.
Nearly every laminate fault traces to one of four installation errors: no expansion gap or a gap that has been bridged, a subfloor out of tolerance, moisture in the subfloor or the planks, or joints not fully engaged. A fifth, water damage from a leak or mopping, shows as swollen edges and is not repairable. The diagnosis takes a straightedge, a moisture meter and ten minutes under the skirting. The fixes range from trimming the beading to lifting the floor and levelling the slab. This guide gives the diagnosis sequence, the four causes with the evidence for each, the repairs with time and cost, and the installation rules that stop it happening again. For the installation method see laminate flooring installation guide; for subfloor testing see moisture testing floors.
Key Facts
- Expansion gap — 8–10 mm minimum at every wall, pipe, door frame, threshold and fixed unit, and more (12–15 mm) on rooms over 8 m in either direction; most manufacturers require an expansion profile in a doorway and at every 8–10 m of continuous run
- Movement — laminate's HDF core moves with humidity; 1–2 mm per metre between winter and summer in a UK house is normal, so a 5 m room moves 5–10 mm. The gap exists to take it
- Fixed points — anything screwed or nailed through the floor (kitchen plinth clips, a door stop, a radiator pipe collar glued to both floor and pipe, heavy fitted furniture on one side) pins the floor and the movement concentrates at the free edge
- Subfloor flatness — BS 8201:2011 (wood flooring) and the laminate makers' instructions require a surface regularity of 3 mm in 2 m (SR1 in BS 8204-1 terms); a hollow deeper than that lets the planks flex and the click joints fatigue
- Underlay — 2–3 mm high-density foam or fibreboard is standard; thick soft underlay (5 mm+ "comfort" foam) lets the joints hinge and fail. Underlay with an integral damp-proof membrane is required over concrete; a separate 1,000-gauge polythene DPM is the alternative
- Subfloor moisture — concrete must read below 75% RH by the insulated hood hygrometer test (BS 8201 and BS 8203), or below the maker's figure (often 2–2.5% by carbide bomb test); new concrete dries at roughly 1 mm per day so a 100 mm slab needs 3–4 months. Timber subfloors should be below 16% moisture content and within 2–3% of the laminate
- Acclimatisation — planks stored flat in the room for 48 hours minimum in the heating conditions the room will see; laid straight from a cold van they expand after fitting
- Click joints — planks must be fully engaged along the long edge and tapped home on the short edge with a tapping block; a joint 0.5 mm open on day one is a 2 mm gap in a year
- Door bars and thresholds — the floor must be free to move under a T-bar or a ramp profile; a bar screwed down through the laminate pins it
- Skirting and beading — skirting fixed to the wall over the gap, or scotia beading fixed to the skirting and not the floor, lets the floor move; beading nailed down into the planks does not
- Underfloor heating — laminate over UFH needs a maximum floor surface temperature of 27°C and a thin underlay (thermal resistance under 0.15 m²K/W); a thick underlay or a system run hot dries and shrinks the boards
- Water damage — swollen, raised edges with a soft core are irreversible; a leak from a dishwasher, a radiator valve or mopping with a wet mop is the usual cause
- Joist floors — floorboards or chipboard that flex are a bouncing floor whatever is laid on them; the fix is the subfloor (screw down, overboard with 6 mm ply), not the laminate
- Peaking vs cupping — peaking (joints raised) is expansion against a fixed point; cupping (plank edges raised, centre low) is moisture from below
- Time on site — perimeter gap check and beading trim 1–2 hours; relay a section over a levelled hollow half a day; lift, level and relay a 20 m² room 1–2 days
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Symptom | Likely cause | Evidence | Fix |
|---|---|---|---|
| Ridge or peaked joints across the room, worse in summer | Expansion gap closed or bridged | Lift beading: planks touching skirting or pipe collar | Cut back to 10 mm; free the fixed point; relay the ridge |
| Floor lifting at one wall or in a doorway | Door bar or threshold pinning the floor | Bar screwed through planks | Refit the bar to the subfloor only, or use a clip-in profile |
| Whole floor domed, edges swollen | Moisture from the slab (no DPM) or flooding | Cupped planks; high RH reading | Lift; dry; new DPM; relay with new boards |
| Soft or drumming spot; joints clicking | Subfloor hollow or thick underlay | Straightedge shows 3 mm+ dip | Lift section; level with compound; relay with thin underlay |
| Bounce everywhere, floor moves underfoot | Flexing timber subfloor | Feel for joist deflection; look below | Screw down; overboard with ply; then relay |
| Gaps opening at the short ends in winter | Shrinkage after wet laying, or joints not clicked | Gap widens with heating season | Pull together with a pull bar; add a fixed point at one wall only; relay if widespread |
| Gaps that do not change with season | Joints never engaged | Even gaps, not seasonal | Lift and relay from the gap |
| Edge swelling along a run near a kitchen or radiator | Water ingress | Soft, raised edges | Replace planks; find and fix the leak |
| Planks lifting at a kitchen plinth | Plinth or unit legs screwed through the floor | Screws through laminate | Remove screws; cut the floor back under the plinth |
Detailed Guidance
Diagnostic sequence
LAMINATE FLOOR FAULT
│
├─ LIFTING / PEAKING
│ ├─ Lift the beading or skirting at two walls. Is there an 8–10 mm gap?
│ │ ├─ No: planks hard against wall/pipe/door bar ──► EXPANSION: cut back; free fixed points
│ │ └─ Yes ──► check for pinning: door bars, plinth screws, glued pipe collars
│ ├─ Planks cupped, edges up, floor domed? ──► MOISTURE FROM BELOW: hygrometer; DPM; relay
│ └─ Localised swelling, soft edges? ──► WATER DAMAGE: find leak; replace planks
│
├─ BOUNCING / DRUMMING
│ ├─ Straightedge 2 m across the spot: dip over 3 mm? ──► SUBFLOOR: level and relay
│ ├─ Underlay thicker than 3 mm or crushed? ──► UNDERLAY: relay on 2–3 mm high-density
│ └─ Whole floor moves; joists below? ──► TIMBER SUBFLOOR: screw/overboard
│
└─ GAPPING
├─ Gaps come and go with the seasons? ──► SHRINKAGE: laid wet or no acclimatisation
├─ Gaps constant since laying? ──► JOINTS NOT ENGAGED: pull up and relay
└─ Gaps only at a doorway or under a heavy unit? ──► PINNING: floor dragged by a fixed point
Lifting and peaking: find the fixed point
Take the scotia or lift the skirting at the two walls nearest the lift and at any pipe. The planks should stop 8–10 mm short of the wall; if they touch it, the floor has nothing to expand into and the lift is the result. Look for the other ways a floating floor gets pinned: a door bar screwed down through the planks rather than into the subfloor between them, a radiator pipe collar glued to the pipe and the floor, kitchen plinth clips or unit legs screwed through the laminate, a fitted wardrobe standing on it, a heavy stop bead nailed through. A floor pinned at one side moves twice as much at the other.
Fix the cause before the symptom. Cut the planks back with a multi-tool to leave 10 mm at every wall and 10 mm radius clearance at pipes, remove the screws through the floor and refit the bar or the plinth to the subfloor, and replace a glued collar with a loose one. Then relieve the ridge: on a click floor, taking the pressure off is often enough for it to settle over a week, but a peaked joint that has been forced may have broken the tongue and needs the two planks lifted and replaced. Anything over 8 m should have had an expansion profile; retrofitting one means cutting a 20 mm strip out across the room and fitting a T-profile, which is half a day and sometimes the only answer in a long hall or an open-plan room.
Moisture: from the slab, the air or a leak
Cupping, a domed floor and swollen edges along every joint mean water has got into the HDF core, and the question is where from. A ground-floor slab with no damp-proof membrane under the underlay, or an underlay without an integral DPM, lets vapour through year-round, and the floor swells from below. Test the slab with an insulated hood hygrometer left for 72 hours: a reading over 75% RH confirms it. A floor laid on a slab that was poured three weeks earlier fails the same way. The repair is to lift the floor (most of it will be scrap), let the slab dry or apply a surface DPM, lay a 1,000-gauge polythene DPM or a DPM underlay with taped joints turned up at the walls, and relay with new boards.
Swelling in one area, especially near a kitchen, a bathroom door or a radiator, is a leak or wet mopping, and the planks are finished. Find the water first; see dishwasher leaking and washing machine leaking for the usual culprits. Laminate is not a wet-room product and a floor washed with a soaking mop every week will swell at the joints within a year.
Bouncing: the subfloor and the underlay
Lay a 2 m straightedge across the soft spot in two directions. A dip you can slide a 3 mm packer under is outside the tolerance and the planks are bridging it; every footstep flexes the click joints and in time they open and start clicking. The common culprits are a slab with a hollow where a wall was removed, a chipboard floor with a sag between joists, old floorboards with cupped edges, and a thick foam underlay that has compressed under traffic. Soft "comfort" underlays over 3 mm, and two layers of underlay over an old one that was never lifted, cause bounce by themselves.
Lift the planks back to the affected area (click floors can be unzipped from the last row, but tongues break, so allow for 10–15% replacement), check the underlay and the subfloor, and level: self-levelling compound over a primed slab for a hollow, a feather finish for a shallow dip, 6 mm plywood screwed at 150 mm centres over boards, or screwing down loose chipboard and filling joints. Relay on a 2–3 mm high-density underlay. A timber floor that flexes at the joists needs the joists looked at, not the finish; see subfloor preparation guide and floor levelling compounds.
Gapping: shrinkage and unlocked joints
Gaps that open in the heating season and close in summer mean the boards were laid with more moisture than the room's equilibrium: not acclimatised, laid in a damp new build, or in a house that was unheated when they went down. Seasonal gaps of 1–2 mm are a cosmetic problem the customer can live with or that can be improved by pulling the floor together with a pull bar from one wall and fitting a stop at that wall only (a bead of flexible adhesive under the first row is a common trick), leaving the other walls free. Widespread gapping on a floor that was laid wet will keep moving and relaying is the honest answer.
Gaps that have been there since the floor was laid and do not change are joints that were never clicked fully home: the fitter did not tap the short ends, or a wedge of underlay or grit sat in the joint. A single gap can be pulled closed with a pull bar from the nearest wall if the planks between it and the wall are free; more than a few means lifting back to the first gap and relaying with a tapping block on every short edge. Check the long-edge angle: most systems click at 20–30° and a plank pushed in flat is only half engaged.
Repairs, time and cost
| Repair | Time | Typical charge (2026) |
|---|---|---|
| Diagnosis, lift beading, cut back expansion gap, refit beading, one room | 1–2 h | £90–£180 |
| Refit a door bar or threshold to the subfloor | 30 min | £40–£80 |
| Retrofit an expansion profile across a long room | 2–4 h | £120–£240 |
| Lift a section, level a hollow, relay (2–4 m²) | 3–5 h | £180–£350 plus compound |
| Replace water-damaged planks (4–6 planks, matching stock available) | 2–3 h | £120–£220 |
| Lift, DPM, relay a 20 m² room with new laminate | 1.5–2 days | £400–£700 labour plus £300–£600 materials |
| Overboard a timber subfloor with 6 mm ply, 20 m², then relay | 1 day plus relay | £350–£600 plus ply |
Make the quote conditional on matching planks being available (manufacturers change ranges every two or three years) and on what the straightedge and the hygrometer find under the first lifted section. See laminate flooring fitting pricing guide.
Laying it so it does not come back
Acclimatise 48 hours in the heated room. Test the slab for moisture and lay a DPM or DPM underlay with taped joints. Check flatness with a 2 m straightedge and level anything over 3 mm. Use a 2–3 mm high-density underlay, one layer. Leave 10 mm at every wall, pipe, frame and unit, and 12–15 mm or an expansion profile in rooms over 8 m. Fix skirting and beading to the wall, never through the floor. Fit door bars to the subfloor with the floor free underneath. Tap every short edge home. Do not screw anything through it afterwards and tell the customer not to. See laminate flooring installation guide.
Frequently Asked Questions
Can a laminate floor that has lifted go back down?
If the lift is expansion against a fixed point and the tongues have not broken, yes: free the floor and it usually settles within a week or two as the pressure comes off. If the ridge has been walked on for months the click joints at the peak are likely cracked and those planks need replacing. If the lift is moisture swelling, the boards have grown permanently and will not go back.
The fitter left a gap. Why has the floor still lifted?
Because something else is pinning it. The usual culprits are a kitchen plinth or unit legs screwed through the floor, a threshold bar fixed through the planks, a pipe collar glued down, or heavy fitted furniture on one side. A floor pinned on one side moves all its expansion to the other side and closes a 10 mm gap that was adequate. Find the fixed point.
Is it the laminate's fault? Can the customer claim on the warranty?
Manufacturers' warranties exclude installation faults (gap, subfloor, moisture) and water damage, which between them cover nearly every failure. A genuine product fault (delamination of the wear layer, joints that break under normal use) is rare and would show across the whole floor. Be straight with the customer: if the gap is closed or the slab is wet, it is the installation, and the claim is against the installer.
Can I fix a bouncy spot by injecting something under the floor?
Injection products exist for solid floors with a void under a bonded finish; they are not a fix for a floating laminate over a hollow, because the laminate is not bonded to anything and the void is under a compressible underlay. Lift the section and level the subfloor. A bounce over joists is the joists.
Does underfloor heating cause laminate to gap?
It can if the floor surface runs over 27°C, the underlay is thick (thermal resistance over 0.15 m²K/W) or the heating was turned on full the day the floor went down. Boards dry out and shrink, and the gaps appear within the first heating season. Run the system at a low flow temperature for the first week, keep the surface below 27°C, use a UFH-rated underlay, and acclimatise the boards with the heating on.
Regulations & Standards
BS 8201:2011 — code of practice for installation of flooring of wood and wood-based panels; subfloor regularity and moisture limits
BS 8203:2017 — code of practice for installation of resilient floor coverings; the insulated hood hygrometer test for subfloor moisture (75% RH)
BS 8204-1:2003+A1:2009 — screeds, bases and in situ floorings; concrete bases and cementitious levelling screeds, surface regularity classes
BS EN 13329:2016+A2:2021 — laminate floor coverings; elements with a surface layer based on aminoplastic thermosetting resins, specifications, requirements and test methods
BS EN 14041:2018 — resilient, textile, laminate and multilayer modular floor coverings; essential characteristics
BS 8425:2003 — code of practice for installation of laminate floor coverings (under revision by BSI; CEN/TS 14472-3 is the European equivalent)
Building Regulations 2010, Approved Document C — resistance to moisture; damp-proof membranes in ground floors
Building Regulations 2010, Approved Document E — resistance to sound; impact sound on separating floors where laminate is laid in flats
BS 8425 — installation of laminate floor coverings — BSI — the laminate-specific code of practice
Subfloor moisture testing — Contract Flooring Association — hygrometer and carbide test guidance
Approved Document C — GOV.UK — DPM requirements in ground floors
Laminate flooring installation guidance — European Producers of Laminate Flooring (EPLF) — expansion gaps, acclimatisation and underlay recommendations
Underfloor heating and floor coverings — BEAMA Underfloor Heating — surface temperature and thermal resistance limits for timber-based floors
laminate flooring installation guide — laying laminate correctly
moisture testing floors — hygrometer and carbide bomb tests
subfloor preparation guide — levelling and overboarding
floor levelling compounds — compounds for hollows and dips
lvt vs laminate comparison — when a resilient floor is the better choice
laminate flooring fitting pricing guide — pricing relays and repairs