Summary
Carbon monoxide alarms cause more confusion per unit than any other safety device in the home, because almost every sound they make is a beep and the consequences of misreading one range from a wasted battery to a death. Tradespeople get the call in three forms: the customer who heard four beeps, silenced it and wants to know if they can put the heating back on; the customer with a chirping alarm who has changed the battery twice; and the landlord who needs to know whether the alarm their tenant is complaining about is compliant. Each needs a different answer, and the answers depend on reading the pattern and the markings on the alarm correctly.
The engineering behind it is straightforward. A domestic CO alarm uses an electrochemical sensor that generates a current proportional to the CO concentration. The alarm integrates concentration over time (because CO harm is a function of both), and triggers on the curve set by BS EN 50291-1: a low concentration takes a long time to alarm, a high one alarms within minutes. The sensor has a finite life, after which it cannot be trusted, so the alarm counts down from activation and tells you when it is done. The battery, the sensor and the electronics each have a distinct fault signal, and manufacturers have (mostly) converged on the same conventions: four beeps for alarm, one chirp for battery, a different count or a display code for fault and end of life.
This guide gives the patterns and what to do about each, the regulations that require CO alarms in rented and newly fitted homes, the siting rules that stop alarms false-triggering or missing real CO, what a tradesperson should do after a genuine activation, and the test equipment that confirms whether there was CO or not. For alarm siting see co alarm positioning; for the physiology and sources of CO see carbon monoxide; for the smoke alarm equivalent see smoke alarm beeping intermittently.
Key Facts
- Alarm pattern — four beeps, pause, repeat, with a flashing red LED: carbon monoxide detected at or above the BS EN 50291-1 threshold curve. Treat it as real until proven otherwise
- Low battery — one chirp every 30–60 seconds, often with a yellow or amber LED; on replaceable-battery models change the battery (usually 3 × AA or a 9 V); on sealed 10-year models a low battery means end of life
- Fault — a chirp every 30–60 seconds with a yellow LED and a different count (commonly three or five), or "ERR"/"FLT" on a display: sensor or circuit fault; the alarm is not protecting the room and must be replaced
- End of life — a chirp that persists with a new battery, "END" or "EOL" on a display, or a dedicated end-of-life pattern (often two chirps): the sensor has reached its design life (7 or 10 years from the activation date on the label). Replace
- Alarm thresholds (BS EN 50291-1:2018) — no alarm at 30 ppm for 120 minutes; alarm at 50 ppm between 60 and 90 minutes; alarm at 100 ppm between 10 and 40 minutes; alarm at 300 ppm within 3 minutes
- Why the delay — the standard deliberately prevents alarms at low concentrations for short periods (a gas hob briefly producing 30 ppm) so that alarms are credible; a four-beep alarm is therefore never a false alarm to be ignored
- Sensor life — electrochemical cells degrade from the moment they are activated; alarms are marked with a replace-by date or a life (5, 7 or 10 years). Many alarms ship with a battery pull-tab; the clock starts when the tab is pulled
- Required standard — BS EN 50291-1:2018 for domestic premises; look for the Kitemark or another third-party certification mark. Alarms to BS EN 50291-2 are for caravans, boats and camping; a smoke alarm is not a CO alarm and a combined unit must carry both standards
- England, private and social rented — the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 as amended from 1 October 2022: a CO alarm in every room used as living accommodation containing a fixed combustion appliance (excluding gas cookers); landlords must repair or replace a faulty alarm once told
- England, new installations — Building Regulations Approved Document J (as amended in 2022) requires a CO alarm to be fitted when any fixed combustion appliance (excluding gas cookers) is installed in a dwelling, not only solid fuel appliances as before
- Wales and Scotland — Wales: Renting Homes (Wales) Act 2016 fitness requirements (see smoke co alarm regulations wales); Scotland: the Tolerable Standard (from February 2022) requires a CO alarm wherever there is a fixed combustion appliance or a flue, in all homes
- Siting (BS EN 50292:2013) — in the same room as the appliance, 1–3 m horizontally from it; ceiling-mounted at least 300 mm from any wall; wall-mounted above door and window height and within 150 mm of the ceiling; not in a cupboard, behind furniture, next to an extractor, window or air vent, directly above a sink or cooker, or where temperature falls below 0 °C or exceeds 40 °C
- Testing — press the test button monthly (tests the circuit and sounder, not the sensor); a sensor test requires a CO test gas aerosol or a calibrated analyser reading; never test with vehicle exhaust, a cigarette or a lighter
- Confirming CO — a Gas Safe engineer or heating engineer uses a flue gas analyser and an ambient CO meter; ambient readings above 10 ppm in a room need investigation, and the appliance should be checked for spillage with a smoke match or spillage test
- Health thresholds — CO is colourless and odourless; the workplace exposure limit in EH40/2005 is 20 ppm over 8 hours and 100 ppm over 15 minutes; symptoms (headache, nausea, dizziness, flu-like) start at sustained exposures above about 70 ppm; 400 ppm is life-threatening within three hours
- Pricing (2026) — replacement battery alarm £15–£30 supply, fitted and tested £40–£80; sealed 10-year alarm £25–£45 supply; interlinked mains or RF CO alarm added to a smoke alarm system £80–£160 fitted; post-activation appliance safety check by a Gas Safe engineer £80–£150
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Sound / indication | Meaning | Customer action | Tradesperson action |
|---|---|---|---|
| 4 beeps, pause, 4 beeps, repeating; red LED flashing | CO detected (alarm) | Open doors and windows, get out, turn off appliances if safe, call 0800 111 999, do not re-enter until clear | Do not use appliances until a Gas Safe/registered engineer has checked them; ambient CO reading; spillage and flue tests; find the source |
| Alarm stopped after ventilation, now silent | Concentration fell below threshold | Still treat as a real event; keep appliances off | Full appliance and flue check before use; read the peak-level memory if the alarm has one |
| 1 chirp every 30–60 s, yellow/amber LED | Low battery | Replace battery (AA/9 V) or replace sealed unit | Check the alarm's date; if within 1–2 years of end of life, replace the unit |
| Chirp continues after new battery | End of life, or fault | Replace alarm | Fit BS EN 50291-1 alarm, record activation date, dispose of old unit as WEEE |
| 3 or 5 chirps, or "ERR"/"FLT" on display, yellow LED | Sensor or circuit fault | Replace alarm | Replace; check environment (humidity, temperature extremes, aerosols) that may have killed the sensor |
| "END", "EOL", or two chirps repeating | End of sensor life | Replace alarm | Replace |
| Green LED flashing every 30–60 s | Normal operation (power indicator) | None | None |
| Beeps when test button pressed, then silent | Test successful | None | Record test |
| Alarm sounds only when cooking or using a gas hob | Possibly real: hob producing CO; or alarm sited too close to the hob | Ventilate; have hob checked | Ambient CO reading while hob runs (above 10–15 ppm is a fault); check siting against BS EN 50292 |
| Alarm sounds at night with no appliances running | Real CO from a neighbouring flat, a flue in a shared chimney, a car in an attached garage, or a boiler cycling | Evacuate; call 0800 111 999 | Investigate shared flues, party walls and garages; do not dismiss |
Detailed Guidance
Step 1 — identify the pattern
Ask the customer exactly what they heard and what the lights did. If they say "it kept going off, four beeps at a time, and the red light was flashing", that is an activation and everything that follows is a gas safety procedure, not a fault-finding one. If they say "it chirps once every minute or so", it is battery, fault or end of life, and the alarm is telling you about itself. If the alarm has a digital display, the reading (ppm) or code is on it; many alarms also store the peak concentration recorded, which an engineer can read back via a button sequence in the manual.
What does it sound like?
├─ 4 beeps, pause, repeat, red LED ──────────► CO ALARM: evacuate, ventilate, 0800 111 999,
│ appliances checked before use
├─ 1 chirp every 30–60 s
│ ├─ Replaceable battery? ─► New battery
│ │ ├─ Chirp stops ───────► Battery was low; check replace-by date
│ │ └─ Chirp continues ───► End of life or fault: replace alarm
│ └─ Sealed unit? ─────────► End of life: replace alarm
├─ 3 or 5 chirps, or ERR/FLT ────────────────► Sensor fault: replace alarm
├─ "END"/"EOL" or two-chirp pattern ─────────► End of life: replace alarm
└─ Green flash only, no sound ───────────────► Normal
Step 2 — a genuine activation: what the customer must do
The procedure to give over the phone, in order: stop using all fuel-burning appliances (turn off the boiler, fire, cooker) if that can be done without delay; open doors and windows; get everyone, including pets, out of the property into fresh air; call the National Gas Emergency Service on 0800 111 999 (free, 24 hours) for a gas property, or the oil or solid fuel supplier and a HETAS or OFTEC engineer for other fuels; do not go back in until the alarm has stopped and the emergency service or an engineer has said it is safe; and seek medical advice if anyone has a headache, nausea, dizziness or feels unwell, telling the clinician that CO exposure is suspected. Do not silence the alarm and carry on. Do not assume it was the alarm being faulty because nobody felt ill: at 50 ppm a healthy adult may feel nothing for an hour.
Step 3 — a genuine activation: what the engineer does
The gas emergency service will make the property safe (which usually means isolating the gas supply) but does not repair appliances. The customer then needs a Gas Safe registered engineer (or HETAS/OFTEC for solid fuel and oil) to find the source and clear every appliance before any is used. That means an ambient CO reading in the room on arrival; a visual inspection of each appliance and its flue; a spillage test and flue flow test on open-flued appliances; a combustion analysis with a flue gas analyser on each appliance (CO/CO₂ ratio against the manufacturer's limits; see flue gas analysis); a check of ventilation (purpose-provided ventilation for open-flued appliances to BS 5440-2); and, where nothing is found, consideration of sources outside the property: a shared chimney with a neighbour's appliance, a flue terminal discharging under the customer's window, a car left running in an attached garage, a generator or barbecue. Record everything, including the alarm's peak reading if it has one, and issue a warning notice under the Gas Industry Unsafe Situations Procedure where an appliance is found at risk or immediately dangerous.
Step 4 — low battery, fault and end of life
A chirp every 30–60 seconds with an amber LED is the alarm asking for a battery. Change it with the type specified (alkaline or lithium AA; a 9 V PP3 on older models; never rechargeable cells unless the manual says so). If the chirp stops, check the replace-by date on the back: an alarm within a year or two of it is better replaced now than at 3am in two winters' time. If the chirp continues with a fresh battery, the unit is at end of life or has a sensor fault; either way it is replaced. Sealed 10-year alarms cannot have their battery changed, so a low-battery chirp on one means replace.
Fault patterns vary by manufacturer: three chirps, five chirps, a yellow LED with a chirp, or "ERR" on a display. The sensor may have been killed by extremes (a cold porch, a hot airing cupboard above 40 °C), by high humidity (a bathroom), or by aerosol or solvent exposure (decorating, cleaning products, silicone fumes), or it may simply have failed. Replace it and consider whether the siting contributed.
Step 5 — the replacement alarm
Fit an alarm to BS EN 50291-1:2018 carrying a third-party certification mark (BSI Kitemark, LPCB or equivalent), with a sealed 10-year battery for rented property (fewer landlord visits and no tenant removing batteries), and interlinked with the smoke alarms where the property has an interlinked system or where the local rules require it (Scotland's Tolerable Standard does not require CO alarms to be interlinked with the smoke alarms, but interlinked models are available and sensible). Write the activation date on the unit, press the test button, and leave the manual with the customer. Site it according to BS EN 50292:2013 and the manufacturer's instructions, which take precedence: in the room with the appliance, 1–3 m from it, high on the wall or on the ceiling, away from windows, vents, extractors and cupboards. For a bedroom alarm (recommended where occupants sleep in a room with an appliance or flue), at breathing height near the bed is acceptable under BS EN 50292. See co alarm positioning.
Step 6 — repeated alarms with no CO found
An alarm that activates repeatedly with nothing found is either detecting something real that is intermittent (a boiler that spills only on start-up in certain winds, a neighbour's appliance venting into a shared chimney breast, a flue terminal under an opening window, a car warmed up in the garage on cold mornings) or is sited where a brief, real but harmless source reaches it (directly above a gas hob, or within a metre of a solid fuel stove door that is opened for refuelling). Hydrogen from a charging lead-acid battery (a mobility scooter, a golf trolley) and some cleaning chemicals can also cross-sensitise electrochemical sensors. Use a logging CO meter left in the room for 24–48 hours before concluding the alarm is faulty; and if two alarms of different makes both activate, there is CO.
Landlords and compliance
In England, a landlord must have a CO alarm in every room used as living accommodation that contains a fixed combustion appliance other than a gas cooker (so a boiler in a kitchen, a gas fire in a lounge, a stove in a dining room), must check it is working at the start of each new tenancy, and must repair or replace it as soon as reasonably practicable once a tenant reports a fault; local authorities can fine up to £5,000 per breach. The regulations do not specify the standard, but BS EN 50291-1 is the only sensible choice and is what the guidance recommends. A tenant reporting a chirping CO alarm is a repair notice; a tenant reporting four beeps is an emergency. For Wales see smoke co alarm regulations wales; for the gas safety record that often prompts the alarm check see gas safety certificate.
Frequently Asked Questions
The alarm went off but nobody felt ill. Was it faulty?
Not necessarily, and you should assume not. BS EN 50291-1 alarms are designed not to sound below 30 ppm for two hours, so by the time one sounds there has been a meaningful exposure; at 50 ppm for an hour most healthy adults feel nothing, but children, the elderly, pregnant women and anyone with heart or lung disease are already at risk. Treat every four-beep alarm as real: ventilate, leave, call 0800 111 999, and have the appliances checked before they are used again.
How often should a carbon monoxide alarm be replaced?
When it tells you to, and no later than the date on the back. Sensors last 5, 7 or 10 years from activation depending on the model; the alarm will sound an end-of-life signal when the time is up. Test it monthly with the button, and replace the battery on replaceable-battery models when it chirps or at least annually.
Can a CO alarm go off because of a gas hob or a candle?
A gas hob producing CO in a poorly ventilated kitchen can genuinely raise levels above the alarm threshold, and the fix is a hob service and ventilation, not moving the alarm; take an ambient reading while the hob runs. Candles, incense and a wood-burner door opened for refuelling produce brief low concentrations that should not trigger a compliant alarm unless it is sited very close. Vehicle exhaust from an attached garage, and a neighbour's appliance via a shared chimney, are real sources that are often not suspected.
Is a CO alarm required if the property has only electric heating?
Not in England under the 2015 regulations or Approved Document J, since there is no fixed combustion appliance; if there is a redundant open fireplace or flue, however, Scotland's Tolerable Standard still requires one, and it is good practice everywhere, because CO can enter from a neighbouring property through a shared flue or wall. A gas cooker alone does not trigger the English requirement, but fitting an alarm anyway costs £20–£40.
Where should the alarm go in a room with a boiler?
In the same room, 1–3 m horizontally from the boiler, either on the ceiling at least 300 mm from any wall or high on a wall above door and window height and within 150 mm of the ceiling, and not in a cupboard with the boiler, next to an extractor fan, a window or an air vent, or in a dead corner. If the boiler is in a cupboard, the alarm goes in the room outside the cupboard. Follow the manufacturer's instructions where they differ.
Regulations & Standards
BS EN 50291-1:2018 — Gas detectors: electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements (alarm thresholds, sensor life, fault and end-of-life signalling)
BS EN 50291-2:2019 — CO detectors for continuous operation in a fixed installation in recreational vehicles and boats
BS EN 50292:2013 — Electrical apparatus for the detection of carbon monoxide in domestic premises: guide on the selection, installation, use and maintenance (siting rules)
Smoke and Carbon Monoxide Alarm (England) Regulations 2015 (SI 2015/1693) as amended by the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 — landlord duties in private and social rented homes from 1 October 2022
Building Regulations 2010, Schedule 1 Part J and Approved Document J (2010 edition incorporating 2010, 2013 and 2022 amendments) — CO alarm required on installation of a fixed combustion appliance (excluding gas cookers)
Gas Safety (Installation and Use) Regulations 1998 — appliance safety, Gas Safe registration, landlord's annual gas safety check
Gas Industry Unsafe Situations Procedure (IGEM/G/11) — classification and warning notices for appliances found at risk or immediately dangerous after a CO event
BS 5440-1 and BS 5440-2 — flues and ventilation for gas appliances
Housing (Scotland) Act 1987, Tolerable Standard (as amended February 2022) — CO alarms in all Scottish homes with a combustion appliance or flue
Renting Homes (Wales) Act 2016 and the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022 — CO alarms in rented homes in Wales
EH40/2005 Workplace Exposure Limits (fourth edition, 2020) — CO workplace limits: 20 ppm 8-hour TWA, 100 ppm 15-minute STEL
Waste Electrical and Electronic Equipment Regulations 2013 — disposal of old alarms
Smoke and carbon monoxide alarms: explanatory booklet for landlords — GOV.UK — the 2015 Regulations as amended in 2022
Carbon monoxide poisoning — Gas Safe Register — symptoms, what to do, and the emergency number
Gas safety: carbon monoxide — HSE — HSE guidance on CO in the home
Approved Document J: Combustion appliances and fuel storage systems — GOV.UK — CO alarm requirement on appliance installation
Carbon monoxide poisoning — NHS — health effects and when to seek treatment
Fire and smoke alarms: the law — Scottish Government — Tolerable Standard requirements including CO alarms
co alarm positioning — siting rules under BS EN 50292 in detail
carbon monoxide — sources, physiology and the engineer's response to CO
co alarms — alarm types, standards and selection
smoke alarm beeping intermittently — the smoke alarm equivalent of this diagnosis
flue gas analysis — the combustion test that finds a spilling or badly burning appliance
smoke co alarm regulations wales — the Welsh rented-home requirements
gas safety certificate — the landlord gas safety record and alarm checks
carbon monoxide safety — CO from solid fuel appliances and chimneys