Summary

Carbon monoxide alarms cause more confusion per unit than any other safety device in the home, because almost every sound they make is a beep and the consequences of misreading one range from a wasted battery to a death. Tradespeople get the call in three forms: the customer who heard four beeps, silenced it and wants to know if they can put the heating back on; the customer with a chirping alarm who has changed the battery twice; and the landlord who needs to know whether the alarm their tenant is complaining about is compliant. Each needs a different answer, and the answers depend on reading the pattern and the markings on the alarm correctly.

The engineering behind it is straightforward. A domestic CO alarm uses an electrochemical sensor that generates a current proportional to the CO concentration. The alarm integrates concentration over time (because CO harm is a function of both), and triggers on the curve set by BS EN 50291-1: a low concentration takes a long time to alarm, a high one alarms within minutes. The sensor has a finite life, after which it cannot be trusted, so the alarm counts down from activation and tells you when it is done. The battery, the sensor and the electronics each have a distinct fault signal, and manufacturers have (mostly) converged on the same conventions: four beeps for alarm, one chirp for battery, a different count or a display code for fault and end of life.

This guide gives the patterns and what to do about each, the regulations that require CO alarms in rented and newly fitted homes, the siting rules that stop alarms false-triggering or missing real CO, what a tradesperson should do after a genuine activation, and the test equipment that confirms whether there was CO or not. For alarm siting see co alarm positioning; for the physiology and sources of CO see carbon monoxide; for the smoke alarm equivalent see smoke alarm beeping intermittently.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Sound / indication Meaning Customer action Tradesperson action
4 beeps, pause, 4 beeps, repeating; red LED flashing CO detected (alarm) Open doors and windows, get out, turn off appliances if safe, call 0800 111 999, do not re-enter until clear Do not use appliances until a Gas Safe/registered engineer has checked them; ambient CO reading; spillage and flue tests; find the source
Alarm stopped after ventilation, now silent Concentration fell below threshold Still treat as a real event; keep appliances off Full appliance and flue check before use; read the peak-level memory if the alarm has one
1 chirp every 30–60 s, yellow/amber LED Low battery Replace battery (AA/9 V) or replace sealed unit Check the alarm's date; if within 1–2 years of end of life, replace the unit
Chirp continues after new battery End of life, or fault Replace alarm Fit BS EN 50291-1 alarm, record activation date, dispose of old unit as WEEE
3 or 5 chirps, or "ERR"/"FLT" on display, yellow LED Sensor or circuit fault Replace alarm Replace; check environment (humidity, temperature extremes, aerosols) that may have killed the sensor
"END", "EOL", or two chirps repeating End of sensor life Replace alarm Replace
Green LED flashing every 30–60 s Normal operation (power indicator) None None
Beeps when test button pressed, then silent Test successful None Record test
Alarm sounds only when cooking or using a gas hob Possibly real: hob producing CO; or alarm sited too close to the hob Ventilate; have hob checked Ambient CO reading while hob runs (above 10–15 ppm is a fault); check siting against BS EN 50292
Alarm sounds at night with no appliances running Real CO from a neighbouring flat, a flue in a shared chimney, a car in an attached garage, or a boiler cycling Evacuate; call 0800 111 999 Investigate shared flues, party walls and garages; do not dismiss

Detailed Guidance

Step 1 — identify the pattern

Ask the customer exactly what they heard and what the lights did. If they say "it kept going off, four beeps at a time, and the red light was flashing", that is an activation and everything that follows is a gas safety procedure, not a fault-finding one. If they say "it chirps once every minute or so", it is battery, fault or end of life, and the alarm is telling you about itself. If the alarm has a digital display, the reading (ppm) or code is on it; many alarms also store the peak concentration recorded, which an engineer can read back via a button sequence in the manual.

What does it sound like?
├─ 4 beeps, pause, repeat, red LED ──────────► CO ALARM: evacuate, ventilate, 0800 111 999,
│                                              appliances checked before use
├─ 1 chirp every 30–60 s
│  ├─ Replaceable battery? ─► New battery
│  │  ├─ Chirp stops ───────► Battery was low; check replace-by date
│  │  └─ Chirp continues ───► End of life or fault: replace alarm
│  └─ Sealed unit? ─────────► End of life: replace alarm
├─ 3 or 5 chirps, or ERR/FLT ────────────────► Sensor fault: replace alarm
├─ "END"/"EOL" or two-chirp pattern ─────────► End of life: replace alarm
└─ Green flash only, no sound ───────────────► Normal

Step 2 — a genuine activation: what the customer must do

The procedure to give over the phone, in order: stop using all fuel-burning appliances (turn off the boiler, fire, cooker) if that can be done without delay; open doors and windows; get everyone, including pets, out of the property into fresh air; call the National Gas Emergency Service on 0800 111 999 (free, 24 hours) for a gas property, or the oil or solid fuel supplier and a HETAS or OFTEC engineer for other fuels; do not go back in until the alarm has stopped and the emergency service or an engineer has said it is safe; and seek medical advice if anyone has a headache, nausea, dizziness or feels unwell, telling the clinician that CO exposure is suspected. Do not silence the alarm and carry on. Do not assume it was the alarm being faulty because nobody felt ill: at 50 ppm a healthy adult may feel nothing for an hour.

Step 3 — a genuine activation: what the engineer does

The gas emergency service will make the property safe (which usually means isolating the gas supply) but does not repair appliances. The customer then needs a Gas Safe registered engineer (or HETAS/OFTEC for solid fuel and oil) to find the source and clear every appliance before any is used. That means an ambient CO reading in the room on arrival; a visual inspection of each appliance and its flue; a spillage test and flue flow test on open-flued appliances; a combustion analysis with a flue gas analyser on each appliance (CO/CO₂ ratio against the manufacturer's limits; see flue gas analysis); a check of ventilation (purpose-provided ventilation for open-flued appliances to BS 5440-2); and, where nothing is found, consideration of sources outside the property: a shared chimney with a neighbour's appliance, a flue terminal discharging under the customer's window, a car left running in an attached garage, a generator or barbecue. Record everything, including the alarm's peak reading if it has one, and issue a warning notice under the Gas Industry Unsafe Situations Procedure where an appliance is found at risk or immediately dangerous.

Step 4 — low battery, fault and end of life

A chirp every 30–60 seconds with an amber LED is the alarm asking for a battery. Change it with the type specified (alkaline or lithium AA; a 9 V PP3 on older models; never rechargeable cells unless the manual says so). If the chirp stops, check the replace-by date on the back: an alarm within a year or two of it is better replaced now than at 3am in two winters' time. If the chirp continues with a fresh battery, the unit is at end of life or has a sensor fault; either way it is replaced. Sealed 10-year alarms cannot have their battery changed, so a low-battery chirp on one means replace.

Fault patterns vary by manufacturer: three chirps, five chirps, a yellow LED with a chirp, or "ERR" on a display. The sensor may have been killed by extremes (a cold porch, a hot airing cupboard above 40 °C), by high humidity (a bathroom), or by aerosol or solvent exposure (decorating, cleaning products, silicone fumes), or it may simply have failed. Replace it and consider whether the siting contributed.

Step 5 — the replacement alarm

Fit an alarm to BS EN 50291-1:2018 carrying a third-party certification mark (BSI Kitemark, LPCB or equivalent), with a sealed 10-year battery for rented property (fewer landlord visits and no tenant removing batteries), and interlinked with the smoke alarms where the property has an interlinked system or where the local rules require it (Scotland's Tolerable Standard does not require CO alarms to be interlinked with the smoke alarms, but interlinked models are available and sensible). Write the activation date on the unit, press the test button, and leave the manual with the customer. Site it according to BS EN 50292:2013 and the manufacturer's instructions, which take precedence: in the room with the appliance, 1–3 m from it, high on the wall or on the ceiling, away from windows, vents, extractors and cupboards. For a bedroom alarm (recommended where occupants sleep in a room with an appliance or flue), at breathing height near the bed is acceptable under BS EN 50292. See co alarm positioning.

Step 6 — repeated alarms with no CO found

An alarm that activates repeatedly with nothing found is either detecting something real that is intermittent (a boiler that spills only on start-up in certain winds, a neighbour's appliance venting into a shared chimney breast, a flue terminal under an opening window, a car warmed up in the garage on cold mornings) or is sited where a brief, real but harmless source reaches it (directly above a gas hob, or within a metre of a solid fuel stove door that is opened for refuelling). Hydrogen from a charging lead-acid battery (a mobility scooter, a golf trolley) and some cleaning chemicals can also cross-sensitise electrochemical sensors. Use a logging CO meter left in the room for 24–48 hours before concluding the alarm is faulty; and if two alarms of different makes both activate, there is CO.

Landlords and compliance

In England, a landlord must have a CO alarm in every room used as living accommodation that contains a fixed combustion appliance other than a gas cooker (so a boiler in a kitchen, a gas fire in a lounge, a stove in a dining room), must check it is working at the start of each new tenancy, and must repair or replace it as soon as reasonably practicable once a tenant reports a fault; local authorities can fine up to £5,000 per breach. The regulations do not specify the standard, but BS EN 50291-1 is the only sensible choice and is what the guidance recommends. A tenant reporting a chirping CO alarm is a repair notice; a tenant reporting four beeps is an emergency. For Wales see smoke co alarm regulations wales; for the gas safety record that often prompts the alarm check see gas safety certificate.

Frequently Asked Questions

The alarm went off but nobody felt ill. Was it faulty?

Not necessarily, and you should assume not. BS EN 50291-1 alarms are designed not to sound below 30 ppm for two hours, so by the time one sounds there has been a meaningful exposure; at 50 ppm for an hour most healthy adults feel nothing, but children, the elderly, pregnant women and anyone with heart or lung disease are already at risk. Treat every four-beep alarm as real: ventilate, leave, call 0800 111 999, and have the appliances checked before they are used again.

How often should a carbon monoxide alarm be replaced?

When it tells you to, and no later than the date on the back. Sensors last 5, 7 or 10 years from activation depending on the model; the alarm will sound an end-of-life signal when the time is up. Test it monthly with the button, and replace the battery on replaceable-battery models when it chirps or at least annually.

Can a CO alarm go off because of a gas hob or a candle?

A gas hob producing CO in a poorly ventilated kitchen can genuinely raise levels above the alarm threshold, and the fix is a hob service and ventilation, not moving the alarm; take an ambient reading while the hob runs. Candles, incense and a wood-burner door opened for refuelling produce brief low concentrations that should not trigger a compliant alarm unless it is sited very close. Vehicle exhaust from an attached garage, and a neighbour's appliance via a shared chimney, are real sources that are often not suspected.

Is a CO alarm required if the property has only electric heating?

Not in England under the 2015 regulations or Approved Document J, since there is no fixed combustion appliance; if there is a redundant open fireplace or flue, however, Scotland's Tolerable Standard still requires one, and it is good practice everywhere, because CO can enter from a neighbouring property through a shared flue or wall. A gas cooker alone does not trigger the English requirement, but fitting an alarm anyway costs £20–£40.

Where should the alarm go in a room with a boiler?

In the same room, 1–3 m horizontally from the boiler, either on the ceiling at least 300 mm from any wall or high on a wall above door and window height and within 150 mm of the ceiling, and not in a cupboard with the boiler, next to an extractor fan, a window or an air vent, or in a dead corner. If the boiler is in a cupboard, the alarm goes in the room outside the cupboard. Follow the manufacturer's instructions where they differ.

Regulations & Standards