Summary

"The hot tap just gurgles" is one of the oldest plumbing calls there is, and the honest answer is that most of them are not airlocks at all. On a gravity hot water system the water in the hot pipes is pushed only by the head of water in the cold-water storage cistern in the loft — about 0.1 bar for every metre of height between the cistern water level and the tap. That is not much. A pocket of air at a high point in a 22 mm or 15 mm hot draw-off can be enough to stop it, because the head cannot compress the air pocket out of the way. The same system is fed from a cistern that can run dry when the float valve sticks, and a dry cistern produces exactly the same symptom; the difference is that one is cured in five minutes with a hose and the other comes back the moment the cistern fills and empties again.

This guide gives the tests that separate a genuine airlock from the three mimics, the four ways to purge an airlock in order of preference (and why the old hose-between-the-taps trick is a Water Regulations problem if it is left connected), the places air gets in, and the permanent fixes that stop the call-back. It also covers the cases that are not airlocks but get the name anyway: air in the primary circuit (the boiler side) that stops the cylinder heating, and the spluttering combi that has a different cause entirely.

For how gravity, system and combi hot water differ, see combi vs system vs conventional; for cylinder types and the open-vented arrangement, see hot water cylinder types guide.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Symptom Cylinder hot? Cistern level Most likely cause Fix
Hot tap gurgles, spits, then stops Yes Normal Airlock in hot draw-off Purge (methods 1–3)
Hot tap gives nothing, cold fine Yes Empty or low Float valve stuck; supply isolated Free or replace float valve, refill, then purge if still airlocked
Hot tap dribbles at all outlets Yes Normal Blocked or scaled cold feed to cylinder; part-closed gate valve Check gate valve; replace cold feed
Hot tap dribbles at one outlet only Yes Normal Tap cartridge, flexible tail kinked, isolation valve part closed Local fix at the tap
Hot tap runs cold No Normal Cylinder not heating: boiler, zone valve, cylinder stat, immersion, primary airlock Heating fault, not a draw-off airlock
Hot water fine upstairs, poor downstairs after a bath Yes Drops then recovers Cistern too small or float valve too slow; air drawn at vent Larger cistern or faster float valve; check vent
Airlock returns every few weeks Yes Normal Rising loop in draw-off; cistern running low under heavy draw-off Re-route pipe or fit automatic air vent at the high point
Airlock after any plumbing work Yes Normal System refilled with taps closed Refill with highest hot tap open
Spluttering at a combi or unvented system n/a n/a Not an airlock: mains supply, scaled heat exchanger, flow sensor, PRV Mains-pressure diagnosis

Detailed Guidance

First five minutes: is it actually an airlock?

Before touching a hose, settle three questions.

  1. Is the cylinder hot? Hand on the top third of the cylinder. Cold cylinder means the fault is heating — boiler, motorised valve, cylinder thermostat, immersion, or air in the primary circuit — and no amount of purging the draw-off will help.
  2. Is there water in the cistern? Up the loft ladder. The level should be within 25 mm of the float valve's shut-off point and the valve should be closed and silent. Low or empty means a float valve fault or an isolated supply; an airlock is then a symptom, and the valve is the job.
  3. Does cold water run normally at the same outlet? If both hot and cold are poor at a basin, the fault is the tap, the flexible tails or a local isolation valve, not the hot system.

Only when the cylinder is hot, the cistern is full and the cold runs is it a draw-off airlock or a restricted cold feed. The two are told apart by where the symptom appears: an airlock gives spitting and gurgling and often clears at one tap and not another; a blocked cold feed gives a steady weak dribble at every hot tap, getting worse as the cylinder is drawn down, with no air noise.

Decision tree

"No hot water at the tap" on a cistern-fed system
│
├── Is the cylinder hot at the top?
│   ├── No → heating fault (boiler / valve / stat / immersion / primary air)
│   │        → see no-hot-water-but-heating-works; check F&E cistern level
│   └── Yes → continue
│
├── Is the cold-water storage cistern full, float valve shut?
│   ├── No → float valve stuck / supply off / valve too slow
│   │        → free or replace float valve; refill; THEN test taps again
│   │          (the airlock may have cleared itself as the cistern filled)
│   └── Yes → continue
│
├── Does the cold run normally at the same outlet?
│   ├── No → tap, tails, local isolation valve → local repair
│   └── Yes → continue
│
├── Hot gurgles / spits / runs then stops?
│   ├── Yes → AIRLOCK in hot draw-off
│   │        → purge: method 1 (highest tap open, let head push)
│   │          → method 2 (mains back-feed via hose, then DISCONNECT)
│   │          → method 3 (mixer palm trick)
│   │          → method 4 (drain and refill, highest tap open)
│   │        → then find the cause (below)
│   └── No, steady weak dribble, no air → RESTRICTED COLD FEED
│            → gate valve on cold feed fully open?
│            → cold feed scaled / debris / collapsed flexible → replace
│
└── Airlock clears but returns?
      ├── Rising loop in draw-off → re-route or AAV at the high point
      ├── Cistern empties under heavy draw → larger cistern / faster valve
      ├── Vent pipe too short or draw-off teed above the vent → correct
      └── Cold feed too small (15 mm) → upgrade to 22 mm

Purging the air

Method 1 — let the head do it. Open the highest hot tap in the house fully (usually a bathroom basin or bath). If there is a gate valve on the hot draw-off near the cylinder, close it, wait ten seconds, then open it slowly: the surge of head behind the pocket often shifts it. Leave the tap running until it runs clean. Then open every other hot tap in turn from top to bottom. This works for the common case — air drawn in while a bath was running — and costs nothing.

Method 2 — back-feed from the mains. The trade standby. Take a short hose with a tap connector at each end, connect the kitchen cold tap (mains fed) to the airlocked hot tap, open the hot tap first, then the cold. Mains pressure pushes water backwards up the hot draw-off, through the cylinder and out of the open vent into the cistern, carrying the air with it. Thirty seconds is usually enough; you will hear the vent discharge in the loft if you listen. Close the cold, then the hot, then remove the hose and run the hot tap normally. Two warnings. Never leave the hose connected: a mains-to-stored-water connection is a backflow risk the Water Supply (Water Fittings) Regulations 1999 prohibit without a suitable backflow device, and a permanently connected hose is exactly what a Water Regulations inspector writes up. And on a cylinder that is scaled or old, check the vent is not blocked before you pressurise — a blocked vent and a closed cistern lid turn method 2 into a pressure test of a cylinder designed for 0.3 bar.

Method 3 — the mixer tap. On a kitchen or basin monobloc mixer where hot and cold mix in the body (most budget and mid-range mixers do; high-end "dual-flow" mixers with separate waterways do not), block the spout firmly with your palm or a rag and open both hot and cold. The mains cold back-feeds the hot. Release after twenty seconds and let the hot run. It is method 2 without the hose and works often enough to try first.

Method 4 — drain and refill. For the airlock that reforms every time, or where the pipe run holds air that the head cannot clear. Close the cistern supply (or tie the float valve up), open every hot tap, drain the draw-off from the lowest point — a drain-off cock if there is one, otherwise the lowest hot tap — and when it stops, close the drain and refill with the highest tap open. Air leaves ahead of the rising water. If the airlock returns after a correct refill, the pipework has a trap: find it.

Where the air comes from — and the permanent fix

The cistern ran dry. The float valve stuck (a worn washer or a scaled piston on a Portsmouth valve), the supply was turned off, or a bath and a washing machine together emptied a small cistern faster than a 15 mm valve could refill it. As the level drops below the cold feed outlet at the cistern base, air is drawn into the feed and into the cylinder. Fix the valve — fit a diaphragm type to BS 1212-2 or BS 1212-3 with a decent float — and check the cistern size: 100–115 litres actual capacity is the usual minimum for a house with one bathroom, 230 litres where there are two. Make sure the warning (overflow) pipe is clear and visible.

The system was drained and refilled. After a cylinder swap, an immersion change or a tap replacement, refilling with the hot taps closed leaves air at every high point. Refill with the highest tap open, always.

The pipework has a trap. A hot draw-off that rises from the vent connection, runs across a ceiling, drops to a bathroom, then rises again to a loft shower, holds air at the second high point that no head will clear. The fix is to re-route so the pipe falls continuously from the vent connection to each outlet, or to fit an automatic air vent (with an isolation valve for service) at the high point. On a long run, a 22 mm main with 15 mm branches falling to each tap is the arrangement BS EN 806-2 and BS 8558 intend.

The draw-off is teed above the vent. The hot draw-off should come off the vent pipe no higher than 450 mm above the cylinder top (the manufacturer's connection point), so that the vent carries expansion and any air and the draw-off takes water. A draw-off teed higher up, near the loop over the cistern, pulls air every time a tap opens. Re-make the tee.

Low head and a shower. A gravity shower on a system with less than a metre of head between cistern base and shower head will draw air at the vent when the bath is run. A shower pump needs a dedicated cold feed from the cistern and a hot draw-off from a surrey or essex flange or a dedicated connection, so it never competes with the vent — see shower pump installation.

What this is not: air on the boiler side

The other "airlock" is in the primary circuit — the sealed or open-vented circuit from the boiler through the cylinder coil. Symptoms: cylinder cold or lukewarm, boiler cycling or kettling, pump running but noisy, heating may still work. On an open-vented primary, check the feed-and-expansion cistern in the loft has water in it and its float valve works; a dry F&E cistern is the commonest cause of a cold cylinder on an old system. Bleed the pump (bleed screw on the pump body), any air vent on the primary flow, and the top of the coil if there is a bleed point. On a sealed system, check the pressure gauge (1–1.5 bar cold) and top up before bleeding. See no hot water but heating works and boiler kettling.

The customer who wants it to stop happening

An airlock that keeps returning is a design fault, and the honest advice is one of three things: fix the cistern (valve, size, feed), fix the pipe geometry, or get rid of the cistern. An unvented cylinder (G3-registered installer, mains pressure, no loft cistern) or a combi removes the cause completely, and on a house with a decent mains supply it is often the better value over ten years than three more purge visits. The quote for that is a different article: cylinder replacement and unvented cylinders.

Charging the job

Job Time Parts Typical charge
Diagnose and purge airlock 30–60 min — £60–£120
Replace float valve, refill, purge 45–75 min £15–£40 £90–£160
Replace scaled 22 mm cold feed, cistern to cylinder 2–3 h £30–£80 £180–£320
Re-route looped draw-off or fit AAV at high point 1.5–3 h £20–£60 £150–£350
New cold-water storage cistern, 230 l, with valves and insulation Half a day £120–£250 £350–£550

Agree the diagnostic charge first: a third of these calls end with a float valve and a lecture about the overflow pipe, and the customer who was told "£80 to find it, deducted from the repair" does not argue.

Frequently Asked Questions

How do I get an airlock out of a hot water system?

Open the highest hot tap and, if the system has a gate valve on the hot draw-off, close and reopen it to surge the pipe. If that fails, back-feed mains pressure into the hot tap with a hose from the mains cold tap (or by blocking the spout of a mixer tap with both sides open) for twenty to thirty seconds, then disconnect the hose. If the air returns, drain the hot draw-off and refill with the highest tap open, and look for a rising loop in the pipework.

Why do I keep getting an airlock in my hot water?

Because something keeps letting air in: a cold-water storage cistern that runs low when the bath is run (float valve slow or stuck, cistern too small), a hot draw-off that rises and falls so it holds air at a high point, or a draw-off teed too high on the vent pipe. Purging clears the symptom; the cause is in the loft or the pipe route.

Can a combi boiler get an airlock?

Not in the hot water draw-off: a combi delivers hot water at mains pressure, which pushes any air through to the tap. Spluttering from a combi tap usually means a problem with the incoming mains, a scaled plate heat exchanger or a flow-sensor fault. The combi's heating circuit can hold air, which is a different fault — radiators cold at the top, pump noise, pressure dropping.

Is connecting a hose between the hot and cold taps legal?

As a brief purge, with the hose removed afterwards, it is accepted practice. Leaving it connected is a cross-connection between the mains and stored water, which the Water Supply (Water Fittings) Regulations 1999 prohibit without an appropriate backflow prevention device; it also back-pressurises a vented cylinder that is not designed for mains pressure. Disconnect it as soon as the tap runs clean.

No hot water but the cistern is full and the cylinder is hot — what else is it?

A restricted cold feed between the cistern and the base of the cylinder: a gate valve left part closed, a scaled or sludged 22 mm pipe, or a flexible connector that has collapsed internally. The symptom is a weak, steady dribble at every hot tap rather than spitting and gurgling. Check the gate valve first; replace the feed if it is scaled.

Regulations & Standards