Fire risk assessments are a growing line of work for tradespeople who already install fire doors, alarms and emergency lighting, and a frequent request to electricians and builders working in commercial premises and HMOs. The legal duty sits with the responsible person (the employer, landlord, building owner or managing agent), who must have a suitable and sufficient assessment of the premises and keep it under review. They can carry it out themselves, but most buy it in, and the market for that service is wide open in price and quality.

This guide is for pricing the assessment itself. It covers what an assessment legally has to contain, the four types of assessment used for blocks of flats, how property type and size drive the time on site and the report, what competence the assessor needs to show, and how to price the remedial works that come out of the action plan, which is where most of the income for a trade business sits. For what the assessment involves, see fire risk assessment; for HMO-specific duties see hmo fire safety.

The price mistake in this market is undercharging because the job looks like a walk round with a clipboard. A defensible assessment of a six-storey block takes a day on site, a day writing, and carries the assessor's professional liability for the findings. An assessment at £99 is not an assessment; the fire and rescue service has prosecuted responsible persons who relied on them.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Property type Typical size Assessment type Site time Price (2026)
Small shop or office Under 100 m², single floor PAS 79-1 1–2 hours £200–£400
Shared-house HMO 3–6 bedrooms, 2–3 storeys PAS 79-2 1–2 hours £200–£400
Larger HMO or bedsit conversion 7–15 units PAS 79-2 2–3 hours £350–£600
Purpose-built flats, up to 10 flats 2–4 storeys Type 1 2–3 hours £300–£700
Purpose-built flats, 10–50 flats Up to 18 m Type 1 Half to full day £600–£1,500
Block over 18 m or 50+ flats High-rise Type 1 plus Regulations 2022 items 1–2 days £1,200–£3,000
Type 3 assessment (sample of flats) Any block Type 3 Add 30–60 minutes per flat Add £80–£150 per flat
Restaurant, pub, café Under 300 m² PAS 79-1 2–4 hours £400–£800
Small hotel or guest house 10–30 rooms PAS 79-1 Half to full day £500–£1,200
Care home 20–60 beds PAS 79-1 1–2 days £900–£2,500
School Primary PAS 79-1 1 day £800–£1,800
Warehouse or workshop 500–2,000 m² PAS 79-1 Half to full day £500–£1,500
Church, village hall, community centre Single building PAS 79-1 2–3 hours £300–£600
Annual review of an existing assessment Any Review Half the original 50–60% of the original fee

Detailed Guidance

What the fee has to cover

A compliant fire risk assessment records five things: the fire hazards (ignition sources, fuel, oxygen); the people at risk, including anyone especially at risk such as sleeping occupants, disabled people or lone workers; an evaluation of the risk and the existing measures (detection, alarm, means of escape, compartmentation, emergency lighting, signage, extinguishers, management); the significant findings and an action plan with priorities and timescales; and the arrangements for review. PAS 79-1:2020 and PAS 79-2:2020 give a structured format that fire and rescue services recognise, and most insurers and managing agents ask for a report "to PAS 79".

The fee therefore covers: a pre-visit review of plans, previous assessments, alarm and emergency lighting certificates and fire door inspection records; the site inspection; the report with photographs; and a short meeting or telephone call to walk the responsible person through the action plan. Price in the writing time; it is routinely half or more of the job.

Pricing by time: the build-up

Start with the assessor day rate (£350–£600) and estimate the site hours and the writing hours by property type from the table. Add travel. Add a share of the fixed costs: professional indemnity insurance, register fees (IFE registration is a few hundred pounds a year), CPD and software for the report template. A worked example for a 24-flat purpose-built block of four storeys, Type 1: pre-visit review 1 hour, site inspection 4 hours, report 4 hours, client call 1 hour. Ten hours at £55 per hour (a £440 day rate) is £550; add £60 travel and £90 overhead recovery; £700 before margin. At a 20% margin the fee is £840, which sits in the £600–£1,500 band. A 50-flat block of eight storeys doubles the site and writing time.

For small premises the hourly build-up undercuts the market and should not be used; a £200 minimum fee covers the fixed costs of any visit and report, and the market for a small shop or a three-bedroom HMO is £200–£400 regardless of the two hours it actually takes.

Blocks of flats: types and what changes the price

Type 1 (non-destructive, common parts) is the default for a purpose-built block and what a managing agent means when they ask for "an FRA". It covers the common escape routes, the communal fire doors and the flat entrance doors from the common side, the compartmentation that can be seen, the alarm and emergency lighting in the common parts, and the external walls as far as can be seen. It does not go into flats.

Type 3 adds a sample of flats, non-destructively, to look at flat entrance doors from the inside, the alarms within the flats and the compartmentation between flats; it is used in converted buildings and where there is reason to doubt the construction. Price it by adding 30–60 minutes per flat and the cost of arranging access. Types 2 and 4 are destructive: ceilings opened, risers inspected, and the assessor needs a builder to open up and make good. These are priced as a project, with the builder's time and making good as separate lines, and are rare outside a block already known to have compartmentation problems.

For buildings over 11 m, the Fire Safety (England) Regulations 2022 add a duty to check flat entrance doors annually and communal doors quarterly, and over 18 m a duty to provide plans and external wall information to the fire service and to install a secure information box and wayfinding signage. An assessment of such a block has to check those duties are being met, and the time on site grows accordingly.

HMOs and houses

A shared-house HMO is assessed to PAS 79-2 and the LACORS housing fire safety guidance. It takes an hour or two, but the report has to address the detection grade to BS 5839-6, the protected escape route, fire doors, the kitchen and the cooking arrangements, and the management (tenant information, testing records). £200–£400 is the market. Bedsit HMOs and converted blocks with multiple self-contained units take longer and should be priced at £350–£600. Licensing authorities increasingly ask for the assessment with the licence application or renewal, which drives steady repeat work.

Non-domestic premises

Shops, offices and workshops under about 300 m² on one or two floors are the simplest and are priced at £200–£500. Food premises add the cooking risk, the extraction and the sleeping risk where there are staff flats above; £400–£800. Hotels, guest houses and care homes are sleeping-risk premises where the assessment should include a night-time visit or at least an assessment of night staffing, and the report is longer; £500–£2,500 by size. Schools, warehouses and industrial units are priced by floor area and the complexity of the processes: a single-shed warehouse with racking is half a day; a factory with hot works, flammable storage and shift working is two days.

Competence: what the client will ask for

Since October 2023 the responsible person must be satisfied the assessor is competent, and managing agents and insurers ask for evidence. The recognised routes are a listing on the IFE Fire Risk Assessors Register or the IFSM Tiered Fire Risk Assessors Register for the individual, or BAFE SP205 third-party certification for the company. A Level 3 Certificate in Fire Risk Assessment (or the Level 4 Diploma) plus documented experience is the usual route onto the registers. Without one of these, pricing fire risk assessments for anything beyond a small shop is likely to lose the work to a registered assessor, and leaves the responsible person exposed if the fire service audits the assessment.

For a trade business, the practical route is often to partner with a registered assessor for the assessment and to price the remedial works, or to put one person through the Level 3 or 4 qualification and onto a register.

The remedial works: where the margin is

Every assessment produces an action plan. Typical items for a block of flats: replace or upgrade flat entrance doors to FD30S (priced per door, see fire door installation pricing guide); install self-closers; seal service penetrations in compartment walls with tested fire-stopping; replace or add emergency lighting to BS 5266-1; upgrade or replace the common-parts alarm to BS 5839-1; add signage; clear the escape route. For an HMO: fit a BS 5839-6 Grade D1 LD2 system; fit FD30 doors to the kitchen and bedrooms; fit a heat detector in the kitchen. A trade business doing the assessment should quote these items separately, with the assessment fee stated independently so there is no suggestion the findings were written to generate the work. The works are commonly worth five to twenty times the assessment fee.

Frequently Asked Questions

Can a tradesperson carry out a fire risk assessment?

Legally, anyone the responsible person considers competent can. Practically, the Order as amended requires the responsible person not to appoint an assessor unless they are competent, and the recognised evidence is a register listing or a Level 3 or 4 qualification with experience. A fire door installer or alarm engineer has part of the knowledge; the assessment also covers means of escape, compartmentation, management and the external wall, and the assessor carries the liability for getting it wrong. For small premises a trade business with a qualified person can price and deliver; for blocks of flats, sleeping-risk premises and anything over 11 m, use or partner with a registered assessor.

How often does a fire risk assessment need to be done?

The Order says it must be reviewed regularly and whenever there is reason to think it is no longer valid or there has been a significant change. Industry practice is an annual review and a full reassessment every three to five years, after a fire, after a change of use or layout, or after a change in the occupants (for example, a residential block taking in tenants with mobility impairments). Price the annual review at 50–60% of the original fee; it is a check that the action plan has been done and that nothing material has changed, not a new assessment.

Does the assessor have to be certified?

There is no statutory certification scheme. The duty is on the responsible person to appoint someone competent, and the third-party registers (IFE, IFSM) and BAFE SP205 are how competence is demonstrated. A fire and rescue service auditing a premises will ask who did the assessment and what their qualifications are; an assessment by an unregistered, unqualified person is likely to be treated as not suitable and sufficient, and the responsible person, not the assessor, is the one prosecuted.

What is the difference between a Type 1 and a Type 3 assessment?

Both are non-destructive. Type 1 looks only at the common parts of a block of flats: escape routes, communal doors, the common side of flat entrance doors, communal alarms and lighting, and what can be seen of the compartmentation and the external walls. Type 3 adds a sample of flats, inspected from the inside, to check the flat entrance doors, the detection within the flats and the compartmentation between flats and the common parts. Type 3 is used where the building is a conversion, where the fire doors or compartmentation are in doubt, or where a previous fire has shown problems. It costs £80–£150 more per flat sampled.