Summary
Fire risk assessments are a growing line of work for tradespeople who already install fire doors, alarms and emergency lighting, and a frequent request to electricians and builders working in commercial premises and HMOs. The legal duty sits with the responsible person (the employer, landlord, building owner or managing agent), who must have a suitable and sufficient assessment of the premises and keep it under review. They can carry it out themselves, but most buy it in, and the market for that service is wide open in price and quality.
This guide is for pricing the assessment itself. It covers what an assessment legally has to contain, the four types of assessment used for blocks of flats, how property type and size drive the time on site and the report, what competence the assessor needs to show, and how to price the remedial works that come out of the action plan, which is where most of the income for a trade business sits. For what the assessment involves, see fire risk assessment; for HMO-specific duties see hmo fire safety.
The price mistake in this market is undercharging because the job looks like a walk round with a clipboard. A defensible assessment of a six-storey block takes a day on site, a day writing, and carries the assessor's professional liability for the findings. An assessment at £99 is not an assessment; the fire and rescue service has prosecuted responsible persons who relied on them.
Key Facts
- Legal basis — Regulatory Reform (Fire Safety) Order 2005 (England and Wales), Article 9: the responsible person must make a suitable and sufficient assessment of the risks. Scotland uses the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006; Northern Ireland the Fire and Rescue Services (Northern Ireland) Order 2006.
- Scope widened — the Fire Safety Act 2021 confirmed the Order covers the structure, external walls (including cladding and balconies) and flat entrance doors of multi-occupied residential buildings.
- Recording — Building Safety Act 2022 section 156 (in force 1 October 2023): the full assessment and the fire safety arrangements must be recorded regardless of the number of employees; the responsible person must record the assessor's name and organisation where one is appointed.
- Competence — the Order (as amended) requires the responsible person not to appoint an assessor unless they are competent. Evidence in practice: a place on a third-party register (IFE Fire Risk Assessors Register, IFSM register, BAFE SP205 certification for the company) or a Level 3 or Level 4 fire risk assessment qualification plus experience.
- Methodology — PAS 79-1:2020 (non-domestic premises) and PAS 79-2:2020 (housing) set the recognised format: hazards, people at risk, evaluation, significant findings, action plan with priorities and timescales.
- Regulations 2022 — the Fire Safety (England) Regulations 2022 add duties for buildings over 11 m (fire door checks every 12 months to flat doors and every 3 months to communal doors) and over 18 m (secure information boxes, wayfinding signage, external wall information to the fire service); an assessment of such a building must address them.
- Four types for blocks of flats (from the LGA and Home Office guidance): Type 1 non-destructive, common parts only; Type 2 destructive, common parts; Type 3 non-destructive, common parts plus a sample of flats; Type 4 destructive, common parts plus flats. Type 1 is the default; Types 2 and 4 need a builder to open up and make good and are priced as a project.
- Review frequency — no fixed period in the Order; industry practice is a review every 12 months and a full reassessment every 3–5 years or after any material change, fire, or change of use.
- Assessor day rate — £350–£600 per day in 2026 for a registered assessor; £250–£350 for an in-house assessor's time where the business does its own.
- Time on site — a small shop or office 1–2 hours; a 10-flat block 2–3 hours; a 50-flat block a full day; a care home or hotel 1–2 days including a night-time walk.
- Writing time — usually equal to or more than the site time for a report that records the findings in full with photographs and a prioritised action plan.
- Travel and expenses — priced in or charged at £0.45 per mile plus time for out-of-area jobs.
- Insurance — professional indemnity cover of £1 m or more is expected by managing agents; it is a direct cost of offering the service (£800–£2,500 per year).
- Remedial works — the action plan commonly generates fire door upgrades, compartmentation sealing, emergency lighting, alarm upgrades and signage; these are quoted separately and are the larger income stream.
- VAT — standard 20%; assessments for residential common parts are standard rated.
Quick Reference Table
Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.
Try squote free →| Property type | Typical size | Assessment type | Site time | Price (2026) |
|---|---|---|---|---|
| Small shop or office | Under 100 m², single floor | PAS 79-1 | 1–2 hours | £200–£400 |
| Shared-house HMO | 3–6 bedrooms, 2–3 storeys | PAS 79-2 | 1–2 hours | £200–£400 |
| Larger HMO or bedsit conversion | 7–15 units | PAS 79-2 | 2–3 hours | £350–£600 |
| Purpose-built flats, up to 10 flats | 2–4 storeys | Type 1 | 2–3 hours | £300–£700 |
| Purpose-built flats, 10–50 flats | Up to 18 m | Type 1 | Half to full day | £600–£1,500 |
| Block over 18 m or 50+ flats | High-rise | Type 1 plus Regulations 2022 items | 1–2 days | £1,200–£3,000 |
| Type 3 assessment (sample of flats) | Any block | Type 3 | Add 30–60 minutes per flat | Add £80–£150 per flat |
| Restaurant, pub, café | Under 300 m² | PAS 79-1 | 2–4 hours | £400–£800 |
| Small hotel or guest house | 10–30 rooms | PAS 79-1 | Half to full day | £500–£1,200 |
| Care home | 20–60 beds | PAS 79-1 | 1–2 days | £900–£2,500 |
| School | Primary | PAS 79-1 | 1 day | £800–£1,800 |
| Warehouse or workshop | 500–2,000 m² | PAS 79-1 | Half to full day | £500–£1,500 |
| Church, village hall, community centre | Single building | PAS 79-1 | 2–3 hours | £300–£600 |
| Annual review of an existing assessment | Any | Review | Half the original | 50–60% of the original fee |
Detailed Guidance
What the fee has to cover
A compliant fire risk assessment records five things: the fire hazards (ignition sources, fuel, oxygen); the people at risk, including anyone especially at risk such as sleeping occupants, disabled people or lone workers; an evaluation of the risk and the existing measures (detection, alarm, means of escape, compartmentation, emergency lighting, signage, extinguishers, management); the significant findings and an action plan with priorities and timescales; and the arrangements for review. PAS 79-1:2020 and PAS 79-2:2020 give a structured format that fire and rescue services recognise, and most insurers and managing agents ask for a report "to PAS 79".
The fee therefore covers: a pre-visit review of plans, previous assessments, alarm and emergency lighting certificates and fire door inspection records; the site inspection; the report with photographs; and a short meeting or telephone call to walk the responsible person through the action plan. Price in the writing time; it is routinely half or more of the job.
Pricing by time: the build-up
Start with the assessor day rate (£350–£600) and estimate the site hours and the writing hours by property type from the table. Add travel. Add a share of the fixed costs: professional indemnity insurance, register fees (IFE registration is a few hundred pounds a year), CPD and software for the report template. A worked example for a 24-flat purpose-built block of four storeys, Type 1: pre-visit review 1 hour, site inspection 4 hours, report 4 hours, client call 1 hour. Ten hours at £55 per hour (a £440 day rate) is £550; add £60 travel and £90 overhead recovery; £700 before margin. At a 20% margin the fee is £840, which sits in the £600–£1,500 band. A 50-flat block of eight storeys doubles the site and writing time.
For small premises the hourly build-up undercuts the market and should not be used; a £200 minimum fee covers the fixed costs of any visit and report, and the market for a small shop or a three-bedroom HMO is £200–£400 regardless of the two hours it actually takes.
Blocks of flats: types and what changes the price
Type 1 (non-destructive, common parts) is the default for a purpose-built block and what a managing agent means when they ask for "an FRA". It covers the common escape routes, the communal fire doors and the flat entrance doors from the common side, the compartmentation that can be seen, the alarm and emergency lighting in the common parts, and the external walls as far as can be seen. It does not go into flats.
Type 3 adds a sample of flats, non-destructively, to look at flat entrance doors from the inside, the alarms within the flats and the compartmentation between flats; it is used in converted buildings and where there is reason to doubt the construction. Price it by adding 30–60 minutes per flat and the cost of arranging access. Types 2 and 4 are destructive: ceilings opened, risers inspected, and the assessor needs a builder to open up and make good. These are priced as a project, with the builder's time and making good as separate lines, and are rare outside a block already known to have compartmentation problems.
For buildings over 11 m, the Fire Safety (England) Regulations 2022 add a duty to check flat entrance doors annually and communal doors quarterly, and over 18 m a duty to provide plans and external wall information to the fire service and to install a secure information box and wayfinding signage. An assessment of such a block has to check those duties are being met, and the time on site grows accordingly.
HMOs and houses
A shared-house HMO is assessed to PAS 79-2 and the LACORS housing fire safety guidance. It takes an hour or two, but the report has to address the detection grade to BS 5839-6, the protected escape route, fire doors, the kitchen and the cooking arrangements, and the management (tenant information, testing records). £200–£400 is the market. Bedsit HMOs and converted blocks with multiple self-contained units take longer and should be priced at £350–£600. Licensing authorities increasingly ask for the assessment with the licence application or renewal, which drives steady repeat work.
Non-domestic premises
Shops, offices and workshops under about 300 m² on one or two floors are the simplest and are priced at £200–£500. Food premises add the cooking risk, the extraction and the sleeping risk where there are staff flats above; £400–£800. Hotels, guest houses and care homes are sleeping-risk premises where the assessment should include a night-time visit or at least an assessment of night staffing, and the report is longer; £500–£2,500 by size. Schools, warehouses and industrial units are priced by floor area and the complexity of the processes: a single-shed warehouse with racking is half a day; a factory with hot works, flammable storage and shift working is two days.
Competence: what the client will ask for
Since October 2023 the responsible person must be satisfied the assessor is competent, and managing agents and insurers ask for evidence. The recognised routes are a listing on the IFE Fire Risk Assessors Register or the IFSM Tiered Fire Risk Assessors Register for the individual, or BAFE SP205 third-party certification for the company. A Level 3 Certificate in Fire Risk Assessment (or the Level 4 Diploma) plus documented experience is the usual route onto the registers. Without one of these, pricing fire risk assessments for anything beyond a small shop is likely to lose the work to a registered assessor, and leaves the responsible person exposed if the fire service audits the assessment.
For a trade business, the practical route is often to partner with a registered assessor for the assessment and to price the remedial works, or to put one person through the Level 3 or 4 qualification and onto a register.
The remedial works: where the margin is
Every assessment produces an action plan. Typical items for a block of flats: replace or upgrade flat entrance doors to FD30S (priced per door, see fire door installation pricing guide); install self-closers; seal service penetrations in compartment walls with tested fire-stopping; replace or add emergency lighting to BS 5266-1; upgrade or replace the common-parts alarm to BS 5839-1; add signage; clear the escape route. For an HMO: fit a BS 5839-6 Grade D1 LD2 system; fit FD30 doors to the kitchen and bedrooms; fit a heat detector in the kitchen. A trade business doing the assessment should quote these items separately, with the assessment fee stated independently so there is no suggestion the findings were written to generate the work. The works are commonly worth five to twenty times the assessment fee.
Frequently Asked Questions
Can a tradesperson carry out a fire risk assessment?
Legally, anyone the responsible person considers competent can. Practically, the Order as amended requires the responsible person not to appoint an assessor unless they are competent, and the recognised evidence is a register listing or a Level 3 or 4 qualification with experience. A fire door installer or alarm engineer has part of the knowledge; the assessment also covers means of escape, compartmentation, management and the external wall, and the assessor carries the liability for getting it wrong. For small premises a trade business with a qualified person can price and deliver; for blocks of flats, sleeping-risk premises and anything over 11 m, use or partner with a registered assessor.
How often does a fire risk assessment need to be done?
The Order says it must be reviewed regularly and whenever there is reason to think it is no longer valid or there has been a significant change. Industry practice is an annual review and a full reassessment every three to five years, after a fire, after a change of use or layout, or after a change in the occupants (for example, a residential block taking in tenants with mobility impairments). Price the annual review at 50–60% of the original fee; it is a check that the action plan has been done and that nothing material has changed, not a new assessment.
Does the assessor have to be certified?
There is no statutory certification scheme. The duty is on the responsible person to appoint someone competent, and the third-party registers (IFE, IFSM) and BAFE SP205 are how competence is demonstrated. A fire and rescue service auditing a premises will ask who did the assessment and what their qualifications are; an assessment by an unregistered, unqualified person is likely to be treated as not suitable and sufficient, and the responsible person, not the assessor, is the one prosecuted.
What is the difference between a Type 1 and a Type 3 assessment?
Both are non-destructive. Type 1 looks only at the common parts of a block of flats: escape routes, communal doors, the common side of flat entrance doors, communal alarms and lighting, and what can be seen of the compartmentation and the external walls. Type 3 adds a sample of flats, inspected from the inside, to check the flat entrance doors, the detection within the flats and the compartmentation between flats and the common parts. Type 3 is used where the building is a conversion, where the fire doors or compartmentation are in doubt, or where a previous fire has shown problems. It costs £80–£150 more per flat sampled.
Regulations & Standards
Regulatory Reform (Fire Safety) Order 2005 — the duty on the responsible person to carry out and review a suitable and sufficient fire risk assessment (England and Wales)
Fire Safety Act 2021 — clarifies that the Order covers structure, external walls and flat entrance doors in multi-occupied residential buildings
Building Safety Act 2022, section 156 — full recording of the assessment, assessor competence and information sharing, in force 1 October 2023
Fire Safety (England) Regulations 2022 — additional duties for residential buildings over 11 m and over 18 m
PAS 79-1:2020 — Fire risk assessment. Premises other than housing. Code of practice
PAS 79-2:2020 — Fire risk assessment. Housing. Code of practice
BS 9999:2017 — Fire safety in the design, management and use of buildings. Code of practice
BS 9991:2024 — Fire safety in the design, management and use of residential buildings. Code of practice
BS 5839-1:2017 — Fire detection and fire alarm systems for buildings. Non-domestic premises
BS 5839-6:2019+A1:2020 — Fire detection and fire alarm systems for buildings. Domestic premises
BS 5266-1:2016 — Emergency lighting. Code of practice
Housing Act 2004 — HMO licensing and the Housing Health and Safety Rating System (fire hazard)
Management of Houses in Multiple Occupation (England) Regulations 2006 — fire safety duties on HMO managers
Fire safety in the workplace — GOV.UK — responsible person duties and the assessment
Fire safety risk assessment guides — GOV.UK — sector guides for offices, shops, sleeping accommodation, care homes and more
Fire Safety (England) Regulations 2022 — guidance — duties for buildings over 11 m and 18 m
National Fire Chiefs Council — fire risk assessor competence — competency criteria and the choice of assessor
Institution of Fire Engineers — Fire Risk Assessors Register — register of competent assessors
BAFE SP205 — Life safety fire risk assessment scheme — third-party certification for assessment companies
fire risk assessment — what the assessment involves and how it is structured
fire risk assessment — the legal duties on tradespeople as responsible persons
hmo fire safety — detection grades, fire doors and escape routes in HMOs
fire safety order — the Regulatory Reform (Fire Safety) Order 2005 in detail
fire door installation pricing guide — pricing the most common remedial item
fire door inspection — door checks under the Fire Safety (England) Regulations 2022