Summary

Fire curtains are automatic fire and smoke barriers that deploy from a concealed head box, usually mounted above a ceiling line or within a bulkhead, and descend to compartmentalise a space when triggered by a fire alarm signal. They're specified where conventional fire doors aren't practical — commonly open-plan retail units, atria, reception areas, and increasingly large domestic open-plan kitchen-diner extensions where Building Regulations require fire compartmentation to protect an escape route (typically a stairwell) but the client wants to retain an open-plan layout without a physical door blocking the space day to day.

For tradespeople and contractors pricing this work, the key thing to understand upfront is that fire curtains sit in a different category from most fit-out and joinery-adjacent work: they're a life-safety system, subject to specific commissioning and ongoing servicing requirements, and in most cases should be supplied and installed by a manufacturer-approved or third-party-certified installer rather than fitted generically by a builder or shopfitter. This guide is written for contractors coordinating this work as part of a wider extension or fit-out project — pricing the specialist supply-and-install package, understanding what drives cost, and knowing what to hand off to a certified specialist rather than attempt in-house.

Getting the fire rating and drop height wrong, or having the curtain installed by someone without the relevant competency, isn't just a quality issue — it can mean the completed building fails to satisfy the fire strategy signed off with Building Control, with real consequences for occupancy certification and insurance validity.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Job type Width Fire rating Typical UK price (ex VAT)
Small domestic (single kitchen-diner opening) Up to 3m 30 or 60 minutes £1,800–£3,200
Standard domestic/small commercial 3–5m 60 minutes £2,800–£4,800
Wider domestic/retail opening 5–8m 60 minutes £4,500–£8,000
Commercial/atrium, higher rating 5m+ 120 minutes £7,000–£15,000+
Annual servicing (per curtain, ongoing) N/A N/A £150–£350

Figures assume a single curtain per opening, straightforward head box mounting (accessible ceiling void or exposed bulkhead), and reasonable access for installation. Multiple curtains, structural mullions for very wide openings, or difficult access increase cost significantly.

Detailed Guidance

Who should be pricing and doing this work

This is the point to be explicit about at the outset of any quote involving a fire curtain: this is specialist fire-safety installation work. A general builder should coordinate the opening, head box void, power supply, and fire alarm interface as part of a wider project, but the curtain supply, installation, and commissioning itself should be carried out by a manufacturer-approved or third-party-certified fire curtain installer. Quoting this work as a standard joinery or shopfitting item, or having an uncertified installer fit it to save cost, creates real risk: an incorrectly installed or commissioned fire curtain can fail to deploy correctly in a fire event, and the building's fire strategy sign-off (and insurance position) may not be valid if the installation wasn't carried out and certified by a competent party.

For a contractor managing a project with a fire curtain specified, the practical approach is to obtain a supply-and-install quote from a certified specialist, and price your own coordination role (opening preparation, structural support if needed, power first-fix, liaison with the fire alarm installer) as a separate line item alongside the specialist's quote.

Cost components to price

  1. Curtain and head box supply — the fabric curtain, head box housing, drive mechanism, and guide rails, sized to the opening width and specified fire rating
  2. Structural support/mullion — for openings wider than a single curtain's maximum span, an intermediate structural mullion may be required to support a two-part (or more) curtain arrangement
  3. Installation labour — specialist installer time to fit the head box, guide rails, and commission the mechanism
  4. Electrical interface — connection to the fire alarm system and provision of mains power with battery backup; often priced as a separate electrical first-fix item coordinated with the specialist installer
  5. Commissioning and certification — testing against the fire alarm system, issuing the commissioning certificate for the fire safety documentation pack
  6. Builder's work — preparation of the opening, ceiling void or bulkhead to house the head box, and any making good around the finished installation
  7. Ongoing annual servicing — not part of the initial installation cost, but should be flagged to the client as a required ongoing cost

Worked example — domestic open-plan kitchen-diner, single 4m opening, 60 minute rating

Typical job: a single-storey rear extension creating an open-plan kitchen-diner, where the fire strategy agreed with Building Control requires a 60-minute fire curtain across the 4m opening to the hallway/stairwell to maintain the escape route's fire compartmentation while keeping the space visually open day-to-day.

Item Cost
Fire curtain and head box, supplied (4m width, 60 min rated) £1,850
Guide rails and side channel fixings £220
Specialist installer labour (fitting and commissioning), 1 day £480
Structural bulkhead/void preparation (builder's work) £280
Electrical first-fix (power supply, battery backup wiring) £180
Fire alarm interface and integration testing £150
Commissioning certificate and documentation £120
Making good (ceiling/bulkhead finish around head box) £150
Cost subtotal £3,430
Margin (28%) £960
Quoted price (ex VAT) £4,390
Quoted price (inc VAT) £5,268
First annual service (due 12 months post-install, quote separately) £150–£250

This sits within the standard range for a single domestic-scale fire curtain installation.

Worked example — small retail unit, 6m opening, 60 minute rating, structural mullion required

Typical job: a retail unit shopfront refurbishment where the fire strategy requires a fire curtain across a 6m opening between the sales floor and a rear stockroom/escape corridor, exceeding a single curtain's maximum span and requiring an intermediate structural mullion.

Item Cost
Fire curtain and head box, supplied (two-part, 6m total, 60 min rated) £3,600
Structural mullion, supplied and installed £850
Guide rails and fixings (both sections) £380
Specialist installer labour, 1.5 days £720
Electrical first-fix and battery backup £260
Fire alarm interface and integration testing £220
Commissioning certificate and documentation £150
Builder's work (bulkhead preparation, making good) £420
Cost subtotal £6,600
Margin (28%) £1,848
Quoted price (ex VAT) £8,448
Quoted price (inc VAT) £10,138
First annual service (quote separately) £180–£320

The structural mullion and two-part curtain arrangement push this well above a standard single-width domestic job.

What drives cost beyond width and rating

Servicing and the ongoing cost the client needs to know about

A fire curtain is not a fit-and-forget item. It requires at least annual inspection and servicing by a competent person to remain compliant with the Regulatory Reform (Fire Safety) Order 2005's requirement to maintain fire safety equipment in efficient working order, and this is typically also a condition of the manufacturer's warranty. Flag this clearly at quoting stage — a client who isn't told about the ongoing £150–£350 annual servicing cost per curtain will be an unhappy client when the invoice for it arrives, and an unserviced fire curtain is also a genuine safety and compliance liability for the building's responsible person.

Common pricing mistakes

Frequently Asked Questions

Can a general builder install a fire curtain to save cost?

Not advisable, and in most cases not appropriate. Fire curtains are life-safety fire compartmentation equipment, and installation, commissioning, and servicing should be carried out by a manufacturer-trained or third-party-certified installer. A builder can and should coordinate the surrounding works (opening preparation, structural support, electrical first-fix, making good), but the curtain itself needs specialist supply, installation, and commissioning to be valid against the building's fire strategy and, typically, to be covered by manufacturer warranty and building insurance.

What margin should I target on fire curtain work?

25–30% is typical where you're managing the project and passing through a specialist installer's supply-and-install quote plus your own builder's work. If you're the certified specialist installer pricing the full package directly, margins in the 30–40% range are common given the specialist competency and liability involved.

How do I know what fire rating is required for a given opening?

The required fire rating comes from the building's fire strategy — either a fire engineer's report for larger/commercial projects, or the fire compartmentation requirements agreed with Building Control as part of a domestic extension's Building Regulations approval (commonly relevant to protecting an escape route such as a stairwell in an open-plan layout). Never assume or default to a rating — always obtain it from the project's fire strategy documentation before ordering, since supplying the wrong rating is both a compliance failure and, typically, non-returnable once manufactured to spec.

Does a domestic open-plan kitchen-diner always need a fire curtain, or are there alternatives?

Not always — a fire curtain is one solution among several for maintaining compartmentation around an open-plan layout (others include a conventional self-closing fire door, or redesigning the layout to physically separate the escape route). Fire curtains are typically specified where the client wants to retain a genuinely open, undivided space with no visible door or screen in normal use. Whether it's required at all, and which solution is appropriate, should be determined by the project's fire strategy or Building Control discussion — not decided independently by the installing contractor.

Regulations & Standards