Summary
Getting the pack count right matters more than it seems. Run short by one pack and you lose half a day chasing a matching batch, and a different batch can have a visible colour shift. Over-order by three packs and you have eaten the margin on a small room. The calculation is easy; the judgement is in the wastage allowance, which depends on the room shape, the laying direction and the board length.
Customers often measure rooms themselves and give you a single figure. Always re-measure. Alcoves, bay windows, chimney breasts, hallways that dog-leg and under-stairs cupboards all change the area, and the customer's figure rarely includes them correctly.
This page gives the method, a quick lookup table, worked examples for a simple room, an L-shaped room and a hallway, and the quantities for underlay, DPM, beading and door bars so the whole job can be priced and ordered at once.
Key Facts
- Area — measure each rectangular section, multiply length by width, add them together; measure into door reveals to the centre of the closed door.
- Wastage: straight lay, simple room — 5–10%.
- Wastage: many cuts, alcoves, bays, hallways — 10–12%.
- Wastage: diagonal lay — around 15%.
- Wastage: herringbone or chevron — 15–20% unless the manufacturer advises otherwise.
- Pack coverage — printed on the box; typically between about 1.5 and 2.5 m² per pack depending on board size and thickness.
- Batch — buy all packs from the same batch number to avoid colour variation.
- Acclimatisation — commonly 48 hours in the room, packs flat and unopened or as the manufacturer states.
- Expansion gap — commonly 8–10 mm at walls, pipes and thresholds; follow the manufacturer's figure.
- Long runs — many manufacturers require an expansion profile in runs over about 8–10 m and at doorways between rooms.
- Subfloor moisture — screeds are commonly required to be at or below 75% RH before laying (BS 8201:2011 and manufacturer's instructions); some manufacturers specify lower.
- DPM on concrete — typically 0.2 mm polythene, laps of at least 200 mm taped, turned up the wall behind the skirting, unless the underlay has an integral DPM.
- Flatness — most click systems need the subfloor flat to around 2–3 mm over a 1–2 m straightedge; check the manufacturer's tolerance.
- Use class — check the board's use class to BS EN ISO 10874 (for example 23 for heavy domestic, 32 for general commercial).
- Underfloor heating — check the board and underlay are approved for UFH and the combined thermal resistance is within the system's limit.
Quick Reference Table
Got your quantities? squote builds the full quote with labour, materials and markup.
Try squote free →| Room area (m²) | +7% waste (m²) | Packs @ 1.48 m² | Packs @ 1.73 m² | Packs @ 2.13 m² | Packs @ 2.22 m² |
|---|---|---|---|---|---|
| 5 | 5.35 | 4 | 4 | 3 | 3 |
| 8 | 8.56 | 6 | 5 | 5 | 4 |
| 10 | 10.70 | 8 | 7 | 6 | 5 |
| 12 | 12.84 | 9 | 8 | 7 | 6 |
| 15 | 16.05 | 11 | 10 | 8 | 8 |
| 18 | 19.26 | 14 | 12 | 10 | 9 |
| 20 | 21.40 | 15 | 13 | 11 | 10 |
| 25 | 26.75 | 19 | 16 | 13 | 13 |
| 30 | 32.10 | 22 | 19 | 16 | 15 |
| 40 | 42.80 | 29 | 25 | 21 | 20 |
Packs are rounded up. Adjust the waste percentage for the room shape and layout.
Detailed Guidance
Step 1: Measure the area
- Measure wall to wall at floor level, not at skirting height.
- Split L-shaped and irregular rooms into rectangles and add them.
- Include alcoves, bay windows and the floor under any furniture staying in place only if you will lay under it.
- Measure into door openings to where the threshold or door bar will sit.
- Record measurements to the nearest centimetre and work in metres.
Step 2: Choose the wastage allowance
| Situation | Allowance |
|---|---|
| Rectangular room, boards running the length | 5–7% |
| Room with a chimney breast or bay | 8–10% |
| L-shaped room, hallways, many door openings | 10–12% |
| Diagonal lay | 15% |
| Herringbone or chevron | 15–20% |
| Long boards (1.8 m+) in short rooms | Add 2–3% extra |
The more cuts there are, and the longer the boards relative to the room, the more offcuts end up too short to use.
Step 3: Divide by the pack coverage and round up
Packs needed = (area × (1 + waste %)) ÷ m² per pack, rounded up to the next whole pack.
Worked example 1: rectangular living room
- Room: 4.20 m × 3.60 m = 15.12 m²
- Waste 7%: 15.12 × 1.07 = 16.18 m²
- Pack: 2.13 m²
- Packs: 16.18 ÷ 2.13 = 7.6, so 8 packs (17.04 m² supplied)
Worked example 2: L-shaped kitchen-diner
- Section A: 5.10 m × 3.20 m = 16.32 m²
- Section B: 2.40 m × 2.10 m = 5.04 m²
- Total: 21.36 m²
- Waste 10% (L-shape, multiple doors): 23.50 m²
- Pack: 1.73 m²
- Packs: 23.50 ÷ 1.73 = 13.6, so 14 packs
Worked example 3: hallway
- Hall: 4.80 m × 1.05 m = 5.04 m²
- Plus area by front door: 1.20 m × 0.90 m = 1.08 m²
- Total: 6.12 m²
- Waste 12% (narrow, many door openings and cuts): 6.85 m²
- Pack: 2.22 m²
- Packs: 6.85 ÷ 2.22 = 3.1, so 4 packs
Narrow hallways often waste more than expected because boards are cut down along their length.
Underlay, DPM and trims
Underlay — room area plus about 5% for laps and trimming; underlay comes in rolls or packs, commonly 5–15 m². For worked example 1: 15.12 × 1.05 = 15.9 m², so two 10 m² rolls or one 15 m² roll plus a small top-up. On concrete, use underlay with an integrated DPM or lay a separate DPM. See acoustic underlay selection.
DPM — 0.2 mm polythene sheet to the room area plus laps (200 mm) and upstands at walls; allow about 15% extra.
Scotia or beading — perimeter minus doorways. For worked example 1: perimeter 2 × (4.20 + 3.60) = 15.6 m, minus one 0.8 m door = 14.8 m. In 2.4 m lengths: 14.8 ÷ 2.4 = 6.2, so 7 lengths. Better practice is to remove and refit skirting so it covers the expansion gap without scotia.
Door bars and thresholds — one per doorway where the floor changes, plus expansion profiles in long runs and between rooms as the manufacturer requires.
Adhesive and sundries — panel pins or adhesive for scotia, flexible sealant at bath and kitchen edges, and pipe roses for radiator pipes.
Subfloor checks before ordering
Packs are wasted if the floor is not ready. Before ordering:
- Check screed moisture with a hygrometer; commonly 75% RH or lower before laying. See moisture testing floors.
- Check flatness with a 2 m straightedge and plan levelling compound if needed. See subfloor preparation guide.
- Check for bouncy floorboards; screw them down or overboard.
- Check door clearances: laminate and underlay add 8–12 mm or more, so doors may need trimming.
Pricing the job
The pack count gives the material cost. For labour, most fitters price per m² with extras for doorways, stairs and furniture moving. See laminate flooring fitting pricing guide for current UK rates.
Frequently Asked Questions
How much extra laminate should I order?
For a straightforward rectangular room laid straight, 5–10%. For L-shapes, hallways and rooms with lots of cuts, 10–12%. For diagonal and herringbone layouts, 15–20%. Always round up to whole packs.
Can I return unopened packs?
Many merchants accept unopened packs, but check the policy before relying on it. It is better to keep one spare pack on site for future repairs, especially if the product line may be discontinued.
Do I need underlay for laminate?
Yes, unless the boards have an integral underlay. Underlay provides cushioning, levels minor imperfections and reduces impact noise. On concrete, the underlay or a separate layer must also act as a damp-proof membrane.
What expansion gap should I leave?
Follow the manufacturer's figure, commonly 8–10 mm at walls, pipes and other fixed objects. Laminate expands and contracts with humidity; without a gap it can lift and peak. See laminate floor lifting bouncing or gapping.
How do I calculate a room that is not rectangular?
Split it into rectangles and triangles, calculate each area and add them. For a triangle, area = base × height ÷ 2. Then add the higher end of the wastage range because irregular shapes create more cuts.
Regulations & Standards
BS 8201:2011 — code of practice for installation of flooring of wood and wood-based panels, including subfloor moisture and preparation.
BS EN 13329 — laminate floor coverings, specifications, requirements and test methods.
BS EN ISO 10874 — resilient, textile and laminate floor coverings, classification by use class.
BS 8204-1 — screeds, bases and in-situ floorings, relevant to subfloor preparation.
Manufacturer's installation instructions — expansion gaps, acclimatisation, underlay and UFH compatibility.
BSI — BS 8201:2011 installation of flooring of wood and wood-based panels — installation code of practice
Contract Flooring Association — flooring trade guidance
European Producers of Laminate Flooring (EPLF) — laminate installation and technical information
BSI — BS EN ISO 10874 — use classification of floor coverings
laminate flooring installation guide — how to lay laminate step by step
laminate flooring fitting pricing guide — what to charge for laminate fitting
moisture testing floors — testing screeds before laying
subfloor preparation guide — getting the subfloor flat and sound
lvt vs laminate comparison — when LVT is the better choice