Dust Control on Site: RPE, LEV, Wet Cutting & COSHH Requirements

Quick Answer: Construction dust is a COSHH (Control of Substances Hazardous to Health) hazard. Silica dust from cutting concrete, stone, and masonry causes silicosis — an incurable, fatal lung disease. The law requires you to eliminate dust at source (wet cutting, on-tool extraction) before using RPE (respiratory protective equipment). A simple dust mask (FFP1) is NOT adequate — silica and wood dust require FFP3 or powered air-purifying respirator (PAPR). The WEL (Workplace Exposure Limit) for silica is 0.1 mg/m³ (8-hour TWA).

Summary

Construction dust is one of the most underestimated occupational health hazards in the UK building industry. An estimated 13,000 construction workers die each year in the UK from occupational lung disease, and many thousands more are diagnosed with conditions including silicosis, asbestosis, COPD, and occupational asthma linked to workplace dust exposure. The damage is cumulative, often invisible for years, and irreversible.

Three types of construction dust cause the most serious harm: silica dust (from cutting, grinding, or drilling concrete, stone, brick, and mortar), wood dust (from hardwood and softwood cutting, sanding, and routing — hardwood dust is a known carcinogen), and asbestos dust (see asbestos). All three are subject to specific Workplace Exposure Limits (WELs) under COSHH Regulations.

The hierarchy of dust control follows the standard COSHH hierarchy: eliminate the dust (e.g. choose a non-cutting method); substitute with a less dusty process; enclose or extract at source (LEV — local exhaust ventilation, on-tool extraction); and only then use RPE as the final layer of protection. A dust mask alone is not dust control — it is the last resort, and only effective if it is the right specification and worn correctly.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Dust Type Source WEL (8hr TWA) Minimum RPE Best Control
Silica (respirable) Concrete, stone, brick cutting 0.1 mg/m³ FFP3 or P3 filter Wet cutting + on-tool extraction
Engineered stone Quartz worktop cutting/grinding 0.1 mg/m³ PAPR or FFP3 Wet cutting + on-tool extraction + LEV
Hardwood dust Hardwood cutting, sanding, routing 3 mg/m³ FFP3 or P3 filter On-tool extraction, LEV
Softwood dust Softwood cutting, sawing 5 mg/m³ FFP2 or P2 filter On-tool extraction
Plasterboard dust Cutting gypsum board 4 mg/m³ (resp.) FFP2 On-tool extraction
Cement dust Mixing, cutting, grinding 1 mg/m³ (hardened cement) FFP2–FFP3 Water mist, LEV
Asbestos See asbestos 0.1 f/cm³ See asbestos guidance Licensed contractor
Vacuum Class Filtration Level Use For
L-class 99% at 1 micron General household dust — not adequate for construction
M-class 99.9% at 1 micron Softwood, general construction dust, some ceramic
H-class 99.995% at 0.3 micron Hardwood, silica, asbestos (with correct filter)
RPE Type Filter Class Suitable For
FFP1 disposable <80% efficiency Do not use for hazardous construction dust
FFP2 disposable <94% efficiency Softwood, lower-risk dusts
FFP3 disposable <99% efficiency Silica, hardwood dust, higher-risk cutting
Half-face + P3 filter 99.95% efficiency Sustained silica/hardwood work
Full-face + P3 filter Maximum protection Asbestos non-licensed, high-dust environments
PAPR (powered) APF 20 (TH2) Sustained silica/hardwood; compatible with glasses/beard

Detailed Guidance

COSHH Assessment for Dust

Before starting any work that generates dust, a COSHH assessment is required. For common construction tasks, the HSE provides COSHH essentials guidance and a risk assessment tool online. The assessment must cover:

  1. What substance or dust is involved
  2. What harm can it cause (silicosis, asthma, cancer)
  3. What controls will be used (wet cutting, LEV, RPE)
  4. Emergency procedures (spill, injury)
  5. Monitoring and health surveillance requirements

Health surveillance: COSHH Regulation 11 requires health surveillance where workers are regularly exposed to significant quantities of dust that causes occupational disease. In practice, this means regular chest X-rays or lung function tests for workers regularly exposed to silica or hardwood dust — not just a paper exercise.

Wet Cutting

Wet cutting is the most effective single control for silica dust. Water is applied at the blade to suppress dust at the point of generation. Most angle grinders, disc cutters, and floor saws can be fitted with a water supply adapter.

How to set up wet cutting:

On-Tool Extraction (LEV)

On-tool local exhaust ventilation captures dust at the source. For angle grinders, circular saws, routers, and belt sanders, purpose-designed shrouds and hoods connect the tool to an extraction vacuum.

Requirements:

Fixed LEV systems (for workshop environments):

RPE Selection and Use

Face fit testing: Any tight-fitting RPE (FFP2/FFP3 disposables, half-face masks, full-face masks) must be face-fit tested for the specific wearer using the specific make and model of RPE. A face fit test checks that the face seal is effective. Key points:

Wearing disposable respirators correctly:

Powered air-purifying respirators (PAPRs):

Wood Dust — Specific Considerations

Wood dust is covered by COSHH but often overlooked on site because sawing timber seems less hazardous than cutting concrete. Key facts:

Hardwood dust is a Group 1 carcinogen — it causes nasal and sinonasal cancer (cancer of the nose and sinuses). The cancer typically develops after years of exposure and appears 20–30 years after the exposure period. Exposure limits are set to minimise but not eliminate the risk.

Softwood dust (pine, spruce, larch) causes occupational asthma — again cumulative, after repeated exposure. Carpenters and joiners have higher rates of occupational asthma than the general population.

Controls for wood dust:

Composite wood products (MDF, OSB, chipboard): MDF generates large quantities of fine dust and also contains formaldehyde-based binders — additional COSHH hazard. Use on-tool extraction and FFP3 RPE when cutting MDF.

Site Dust Control Plan

For any project involving significant dust exposure, a simple Dust Control Plan is good practice and evidence of COSHH compliance:

  1. What materials generate dust: List all dusty operations (cutting concrete, sawing hardwood, sanding walls)
  2. Controls at source: Wet cutting, on-tool extraction, task scheduling (wet operations first)
  3. RPE: Type, class, face-fit test status of each operative
  4. Enclosure: Polythene sheeting to isolate dusty areas from clean areas and occupied spaces
  5. Cleaning: Vacuum (not sweep) dust from surfaces; use damp mopping
  6. Waste disposal: Collect and bag silica slurry and wood dust; dispose as hazardous waste if contaminated with asbestos or other chemicals
  7. Health surveillance: For regular workers

Frequently Asked Questions

Is a standard dust mask enough for cutting concrete?

No. A standard dust mask or paper face mask (typically FFP1 or unrated) does not provide adequate protection against respirable silica dust. The particles that cause silicosis are invisible to the naked eye — they pass straight through inadequate RPE and deposit in the lung tissue. FFP3 is the minimum for silica; powered air-purifying respirators (PAPRs) are better for extended cutting work.

I'm cutting engineered stone worktops (quartz) for a kitchen — what do I need?

Engineered quartz surfaces contain 90–95% crystalline silica — the highest silica content of any common construction material. Cutting quartz has caused acute silicosis (severe disease developing within weeks or months) in UK kitchen fitters. Requirements are: wet cutting at all times, on-tool extraction with H-class vacuum, FFP3 or PAPR, restrict access to the work area, clean up slurry correctly. Do not dry cut quartz under any circumstances.

Do I need to control dust when working in an occupied home?

Yes — your duty extends to non-employees including occupants. Dust should be contained using polythene sheeting or temporary enclosures. Inform the customer to vacate the area during dusty operations. Vacuum clean (not sweep) between work sessions. In homes with vulnerable people (children, elderly, people with respiratory conditions), extra precautions are warranted.

How often should I replace the filters in my on-tool extraction vacuum?

Follow the manufacturer's guidance — typically replace filters at a set number of hours of use or when performance (suction) drops. For M-class and H-class vacuums, do not try to clean or re-use paper filters — they are single-use. For H-class vacuums, fit a pre-filter (separator) upstream of the main filter to extend filter life.

Does wet cutting eliminate the need for RPE?

No — wet cutting reduces but does not eliminate airborne silica. Even with wet cutting, some dust becomes airborne at the cutting point. PPE (FFP3 minimum) should still be worn when using wet cutting for sustained operations. The combination of wet cutting plus on-tool extraction plus RPE provides defence in depth.

Regulations & Standards