Summary
LG's error codes are among the most consistent in the industry, which makes them a genuinely useful diagnostic tool. The same two-letter codes have been used across the front-loader range for well over a decade — from the basic Direct Drive models through the TurboWash, AI DD and the washer-dryer ranges — and the letter is a mnemonic for the fault family (I for inlet, O for outlet, U for unbalance, d for door, t for temperature, P for pressure). Suffix numbers (dE1, dE2, tE1, tE2) narrow the fault to a specific switch or sensor on newer models.
The practical trap with LG is the opposite one to brands with vague codes: the code is so specific that it tempts a repairer to order the named part. An IE code does not mean the inlet valve has failed; it means the board did not see the expected water level within its time limit, and a closed stop tap or a scaled inlet filter produces exactly the same code. An LE code does not always mean a dead motor; on the Direct Drive design it is as often a loose Hall (rotor position) sensor connector, a rotor that has worked loose on its shaft, or a wet connector on the motor loom. Work the cheap checks first.
LG's Direct Drive motor, which bolts straight to the back of the drum with no belt, carries a long manufacturer warranty on the motor itself on most models sold in the UK (ten years is commonly advertised at the time of writing). That warranty covers the motor assembly, not labour on most ranges and not the rest of the machine, so check the terms before quoting a motor repair as chargeable.
Key Facts
- IE — inlet error: water level not reached within the fill time limit; check the stop tap, inlet hose, inlet mesh filter and mains pressure before the inlet valve
- OE — outlet (drain) error: water not pumped out within the drain time limit; the drain pump filter is the most common cause, then the drain hose and standpipe
- UE — unbalanced load, final: the machine has tried to redistribute the load and given up; the cycle stops before the spin
- uE (lower case) — unbalanced load, in progress: the machine is still trying to rebalance; this clears itself and is not a fault code
- LE — motor error: the Direct Drive motor has not turned as commanded (locked motor, Hall sensor fault, loose rotor, open winding or a loom connector)
- CE — motor overcurrent: the motor drew too much current, typically an overloaded drum or a motor or PCB fault
- dE / dE1 / dE2 / dE4 — door error: door not closed (dE1), door lock switch not confirming (dE2), door sensor fault (dE4 on some models); plain dE is used on older machines for all three
- FE — overfill: water level above the overflow point; the inlet valve is passing or the pressure sensor is misreading
- PE — pressure sensor error: water level sensor output out of range; a blocked or split pressure hose, or a failed sensor
- tE / tE1 / tE2 / tE3 / tE4 — thermistor error: wash or dryer temperature sensor open or short circuit
- AE — leak detected on models with a base float switch (also used for certain board errors on some ranges, so verify against the model)
- EE — EEPROM error: control board memory fault; PCB replacement
- vS — vibration sensor: on models with a vibration sensor, excessive movement detected; check the feet, transit bolts and floor
- dHE — dryer heater error on washer-dryers: no heating during the dry phase
- FF — frozen: pipework or pump frozen; only seen in unheated outbuildings
- Not faults: CL (child lock), PF (power failure), tCL (tub-clean reminder), Cd (cool down), SUd (excess foam — detergent, not a component)
- Direct Drive motor: bolts to the tub with no belt; the rotor is a magnet ring held by one central bolt; the stator carries the Hall sensor
- RCD protection: 30 mA RCD required for socket-outlets up to 32 A in domestic installations under BS 7671:2018+A4:2026 Regulation 411.3.3
- Plug fuse: 13 A to BS 1362; a 2 kW heater plus the motor is well within the fuse rating under normal load
- Hard water: most of South East England, East Anglia and parts of the Midlands have hard water that scales heaters and inlet filters and is the main driver of tE and IE codes on older machines
- Consumer Rights Act 2015: durability claims against the retailer are possible within six years in England and Wales (five years from discovery in Scotland) if a fault can be shown to be inherent
Quick Reference Table
Diagnosed the problem? Create a repair quote in minutes with squote.
Try squote free →| Code | Family | What the board has detected | First checks on site | Likely repair if checks are clear |
|---|---|---|---|---|
| IE | Water inlet | Fill level not reached in time | Stop tap, hose kink, inlet mesh filter, flow at the tap | Inlet valve (coil open circuit) |
| OE | Drain | Not emptied in time | Pump filter, drain hose, standpipe, impeller free | Drain pump |
| UE | Unbalance (final) | Load could not be balanced | Load size and mix, machine level, transit bolts out | Shock absorbers, suspension springs |
| uE | Unbalance (in progress) | Rebalancing | None — wait | None |
| LE | Motor | Motor not responding | Drum turns by hand, motor loom connectors, Hall sensor plug | Hall sensor, rotor bolt, stator, PCB |
| CE | Motor overcurrent | Excessive motor current | Overload, drum rubbing, bearings | Motor, bearings, PCB |
| dE / dE1 | Door | Door not closed | Door shut firmly, seal clear, strike plate aligned | Door hinge or catch |
| dE2 | Door lock | Lock not confirming | Interlock continuity when latched | Door interlock |
| FE | Overfill | Water above overflow | Machine filling when off? Pressure hose | Inlet valve, pressure sensor |
| PE | Pressure sensor | Level sensor out of range | Pressure hose split/blocked, air chamber scaled | Pressure sensor |
| tE / tE1–tE4 | Temperature sensor | Thermistor open or short | NTC resistance at room temperature | Thermistor (often sold with the heater) |
| AE | Leak | Water in the base tray | Hoses, seal, pump housing | Repair the leak source |
| EE | EEPROM | Board memory fault | Power cycle once | Main PCB |
| PF | Power failure | Supply dropped mid-cycle | Socket, plug, RCD, extension leads | Supply fault, not the machine |
| CL | Child lock | Not a fault | Hold the two marked buttons for 3 seconds | None |
Detailed Guidance
Fault-finding decision tree
START: LG machine stops with a code on the display
│
├─ Is it CL, PF, tCL, Cd or uE? → not a fault
│ ├─ CL: hold the child-lock button pair for 3 s
│ ├─ PF: check the socket, plug fuse and RCD; restart the cycle
│ └─ uE: machine is rebalancing — wait
│
├─ IE (inlet)
│ ├─ Stop tap open? Hose kinked behind the machine?
│ ├─ Inlet mesh filter scaled or full of grit? → clean
│ ├─ Good flow at the tap (fill a bucket)? → no = supply/pressure
│ └─ Valve coil resistance open circuit? → replace valve
│
├─ OE (drain)
│ ├─ Pump filter (kick panel, bottom left on most LG) blocked? → clear
│ ├─ Hose kinked, too far into the standpipe, siphoning? → re-run
│ ├─ Impeller free and winding reads (typically 150–250 Ω)? → no = pump
│ └─ Pump runs, no flow → tub-to-pump hose obstruction
│
├─ UE (unbalance)
│ ├─ Single heavy item or tiny load? → advise the customer
│ ├─ Transit bolts removed? Feet locked and machine level?
│ ├─ Drum drops when pushed down (weak springs/dampers)? → suspension
│ └─ Repeats on every load → shock absorbers / bearings
│
├─ LE / CE (motor)
│ ├─ Drum turns freely by hand? → no = bearings or obstruction
│ ├─ Hall sensor connector on the stator seated and dry?
│ ├─ Rotor bolt tight, rotor not slipping on the shaft?
│ ├─ Stator windings balanced (three similar readings)? → no = stator
│ └─ All good → main PCB (motor drive)
│
├─ dE family
│ ├─ dE1: door physically not closing → hinge, catch, strike plate
│ ├─ dE2: interlock continuity when latched? → no = interlock
│ └─ dE4: door sensor (on models fitted) → sensor or wiring
│
├─ FE / PE (level)
│ ├─ Fills while switched off? → inlet valve passing (FE)
│ ├─ Pressure hose and air chamber clear? → clean
│ └─ Sensor out of range → replace pressure sensor
│
└─ tE family
├─ NTC resistance plausible at room temperature? → no = replace
└─ Good → wiring to the PCB, then PCB
IE: inlet faults
Start at the wall. A stop tap that has been turned off during kitchen work, a hose crushed when the machine was pushed back under the worktop, and a blocked inlet mesh filter account for most IE calls. The mesh filter sits in the valve inlet where the hose screws on; limescale and grit from mains work block it, and it pulls out with long-nosed pliers for cleaning.
LG machines also time the fill against the expected level, so a supply that is simply slow — a shared-supply flat at peak time, or a long run of 15 mm pipe with several fittings — can trigger IE without anything being wrong with the machine. Time a bucket fill at the tap: well under 10 litres a minute on a cold feed will cause intermittent IE on many models.
Only once the supply, hose and filter are proven should you test the inlet valve. A good coil reads a few kilohms; open circuit is dead. A valve that fills very slowly with good pressure usually has a scaled flow restrictor, and replacement is quicker than cleaning on a cheap part.
OE: drain faults
The drain pump filter on LG front-loaders sits behind a small hinged panel at the bottom of the front, usually to the left. It collects coins, hair grips, bra wires and socks, and clearing it is the single most common fix for OE. Drain the water into a tray with the small hose first, then unscrew the filter anticlockwise and check the impeller turns freely.
A clear filter with OE still showing points to the drain hose or the standpipe. The hose must not be kinked, must not be pushed so far into the standpipe that it siphons, and the standpipe needs an air gap; the pump is designed to lift to roughly 600–1,000 mm, so a hose draped over a worktop will not drain. If the pump hums but does not shift water the impeller is jammed or stripped; if it is silent and the winding reads open circuit it is dead. The pump is a separate unit from the filter housing and is a quick swap.
UE and uE: unbalance
Lower-case uE is the machine telling you it is redistributing the load; it clears itself and customers often misread it as a fault. Upper-case UE means it has given up, usually with the clothes still wet. One heavy item (a bath mat, a single pair of jeans) in an otherwise empty drum will trigger UE on any machine, as will a drum stuffed full.
If it repeats on normal loads, look at the installation first: transit bolts still fitted, lock nuts loose on the feet, a machine rocking on an uneven floor or sitting on a flexing timber floor. Then look at the suspension. Push the drum down hard and let go: it should return once and stop. If it bounces, the shock absorbers are worn; if it sits low, the springs have stretched. Dampers are a cheap part but a long job on a Direct Drive machine because the motor and the rear of the tub are in the way.
LE and CE: the Direct Drive motor
The Direct Drive motor is a three-phase outer-rotor motor bolted to the back of the outer tub. The rotor is a ring of magnets on a plastic hub held by a single central bolt; the stator carries the windings and the Hall sensor that tells the board where the rotor is. There is no belt and nothing to slip.
LE means the board commanded the motor to turn and the Hall sensor did not see it. On site the usual causes in order are: a Hall sensor connector that has worked loose or got damp, a rotor bolt that has backed off so the rotor spins on the shaft under load, a drum that will not turn freely (bearings, or something lodged between the drums), a Hall sensor that has failed, and finally a stator winding or the motor drive circuit on the main PCB. The stator windings should read roughly equal between each pair of the three terminals; an open or very unequal reading condemns the stator.
CE is the motor drawing too much current. An overloaded drum or seized bearings are the mechanical causes; a shorted winding or a failed motor drive on the PCB are the electrical ones. CE on an empty drum that turns freely by hand is a board or stator fault.
Check the motor warranty before quoting: LG advertises a long warranty on the Direct Drive motor on most UK models, usually parts only. A stator replacement on a machine still inside that warranty should go through LG's service route.
dE1, dE2 and dE4: door and lock
dE1 on newer models is the door itself: it has not closed far enough for the switch to see it. Sagging hinges on a heavy glass door, a worn catch and a bent strike plate are the causes. dE2 is the interlock: the door is closed but the lock has not confirmed. Isolate the machine, remove the interlock (two screws through the door frame) and check continuity across the lock terminals with the latch pushed in. No continuity means a failed interlock, a cheap and quick repair. dE4, on models fitted with a separate door-closed sensor, is that sensor or its wiring. Plain dE on older machines covers all three, so work the door first and the lock second.
FE and PE: water level
FE is overfill. If the drum fills while the machine is switched off, the inlet valve is passing and must be replaced; this is also a flood risk and the stop tap should be closed until the valve is changed. If it only overfills during a cycle, the pressure sensor is misreading because its hose is split, kinked or blocked, or the air chamber at the bottom of the tub is scaled. PE is the same sensor reading out of range, with the same checks. LG uses an analogue pressure sensor rather than a mechanical switch on most current models, and it is tested by substitution rather than with a meter.
tE codes and the heater
The temperature sensor is usually bonded into the heater assembly or sits next to it in the tub. A thermistor reads a few kilohms at room temperature and falls steadily as it warms; open circuit or short circuit raises tE. On washer-dryers tE2, tE3 and tE4 refer to the dryer duct and condenser sensors and the dHE code accompanies a dead dryer heater.
A separate point: a heater with failing insulation does not usually show a code. It trips the 30 mA RCD at the point in the cycle the heater switches on. Test insulation resistance from each heater terminal to earth; anything below about 2 MΩ will trip an RCD under load and the heater must be replaced.
Pricing an LG repair in 2026
| Repair | Typical price fitted (including diagnostic visit) |
|---|---|
| Clear pump or inlet filter, reset, advise | £60–£110 |
| Door interlock | £85–£140 |
| Drain pump | £110–£170 |
| Inlet valve | £100–£160 |
| Heater with thermistor | £120–£190 |
| Hall sensor | £90–£150 |
| Stator (Direct Drive motor) | £160–£260 (check motor warranty first) |
| Shock absorbers (pair) | £130–£200 |
| Main PCB | £200–£320 |
| Drum bearings (where serviceable) | £200–£320 |
On machines over seven or eight years old with a bearing or PCB failure, replacement is usually the better advice; say so and note it on the job sheet.
Frequently Asked Questions
What is the difference between UE and uE on an LG washing machine?
Lower-case uE means the machine has detected an unbalanced load and is trying to redistribute it; it clears by itself and no action is needed. Upper-case UE means it has tried and failed, and the cycle has stopped before the spin. UE on every load is a suspension or installation problem; UE on single heavy items is just physics.
My LG machine shows CL and will not respond — is it broken?
No. CL is the child lock. It is turned off on most models by holding the two buttons marked with the padlock symbol for about three seconds. PF, shown after a power cut, is also informational; restart the cycle.
Does an LE code mean I need a new motor?
Not usually. On the Direct Drive motor LE is more often a loose or damp Hall sensor connector, a loose rotor bolt or a drum that cannot turn freely. Test the Hall sensor and connectors and check the drum turns by hand before pricing a stator, and check LG's motor warranty for the model before quoting it as chargeable.
Is replacing a washing machine heater or motor notifiable electrical work?
No. Repairing a plug-in appliance is not work on the fixed installation and is outside the scope of Approved Document P. Installing a new socket or a dedicated circuit for the machine is fixed-wiring work that must comply with BS 7671:2018+A4:2026 and is notifiable where it involves a new circuit.
Which LG codes mean the machine should be isolated immediately?
FE (overfill) and AE (leak) both indicate water where it should not be; turn the stop tap off and isolate the machine until the cause is repaired. Any machine that trips the RCD should be unplugged and tested rather than reset repeatedly.
Regulations & Standards
BS 7671:2018+A4:2026 — Requirements for Electrical Installations (IET Wiring Regulations): Regulation 411.3.3 (additional protection by 30 mA RCD for socket-outlets)
Building Regulations 2010, Approved Document P (Electrical safety — dwellings) — appliance repair is outside scope; new circuits are notifiable
BS 1362:1973 — Specification for general purpose fuse links (plug fuses)
BS 1363-1:2023 — 13 A plugs, socket-outlets, adaptors and connection units: Part 1
Electrical Equipment (Safety) Regulations 2016 — product safety for appliances on the UK market
Waste Electrical and Electronic Equipment Regulations 2013 — end-of-life take-back
Consumer Rights Act 2015 — satisfactory quality and durability
Water Supply (Water Fittings) Regulations 1999 — approved inlet hoses and backflow protection at the machine connection
washing machine error codes samsung — Samsung's alphanumeric fault families
washing machine error codes bosch — Bosch E-codes
washing machine error codes beko — Beko E-codes and why the published lists disagree
washing machine not spinning — unbalance, suspension and motor faults in depth
washing machine walking vibrating diagnosis — feet, transit bolts and floors
washing machine leaking — finding the source once AE or a wet floor appears