Summary

"The key won't turn" is the lock call-out that is most often misdiagnosed, because three different components can produce the same symptom and the customer has usually already forced it. A euro cylinder on a uPVC or composite door sits in front of a multipoint gearbox and behind a handle; a mortice sashlock on a timber door has the cylinder (the levers) and the bolt in one case, but the bolt still has to clear a keep in a frame that moves with the seasons. A key that will not turn can mean a cylinder problem, a gearbox or lock-case problem, or simply a door that has dropped 3 mm so the hooks and deadbolt are pressing on the keeps and loading the mechanism so the key cannot move it. Fitting a new cylinder to a door that needs its hinges adjusting fixes nothing and costs the customer £80.

The order of diagnosis is always the same and it is the first thing in the decision tree below: open the door and try again. Everything else follows from that. The second rule is not to force it. A key is a thin piece of brass or nickel silver; the cylinder cam, the gearbox follower and the lock bolt are steel. Forcing the key snaps the key, and a snapped key in a cylinder turns a £20 adjustment into a cylinder replacement. Mole grips on a key are the mark of a locksmith who will be replacing the cylinder whether it needed it or not.

This guide covers euro cylinders in uPVC, composite and aluminium doors, mortice locks and rim cylinders (nightlatches) on timber doors, and the related alignment faults. It gives the diagnostic sequence, the fixes, the standards that replacement hardware must meet for insurance, and the sizing information needed to carry the right cylinder in the van. For the uPVC alignment and gearbox fault where the handle, not the key, is the problem see upvc door wont lock; for lock standards and insurance see security locks; for gearbox replacement see upvc door lock mechanism replacement.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Symptom Door open test result Most likely cause Fix
Key goes in fully, won't turn, door closed Turns fine open Door dropped or swollen; bolts loading keeps Adjust hinges/keeps; plane timber door
Key goes in fully, won't turn, door open or closed Won't turn open Cylinder pin stuck, dirt, worn key, wrong key Lubricate; try spare key; replace cylinder
Key goes in only partway — Foreign object, snapped key tip, damaged pin Extract object; replace cylinder if pin damaged
Key turns but nothing happens Same open Cam sheared or gearbox follower broken Replace cylinder (cam) or gearbox
Key turns 90° then stops, bolt partly out Same open Deadbolt or hook jammed; gearbox fault Check keep clearance; replace gearbox
Key turns only from one side Same open Cam clutch failed on one half (double cylinder) Replace cylinder
Key stiff but turns; getting worse Same open Worn pins, dirt, lack of lubrication Clean and dry-lubricate; replace if no better
Thumbturn turns but key won't — Key worn or wrong; or cylinder clutch Try spare key; replace cylinder
Key turns, handle then won't lift (uPVC) Handle fine open Alignment: hooks missing keeps Hinge and keep adjustment
Key turns, handle won't lift (door open) Same open Gearbox failed Replace gearbox
Mortice lock key won't turn, door open Same open Lever stuck, broken spring, dirt, wrong key Lubricate; strip and clean; replace lock
Nightlatch key won't turn Same open Rim cylinder worn or cam loose; tailbar misaligned Tighten cylinder screws; replace rim cylinder
Key works intermittently Varies Worn key or cylinder; deadbolt catching in cold/heat Spare key test; keep adjustment; replace

Detailed Guidance

Diagnosis: the decision tree

KEY WON'T TURN — DIAGNOSIS
│
├─ 1. Open the door (from inside, or via another door/window if locked out).
│      Try the key with the door OPEN.
│
│   ├─ Key turns normally with door open?
│   │   └─ ALIGNMENT FAULT. Bolts/hooks are loaded against keeps.
│   │       ├─ uPVC/composite: adjust flag hinges (height, lateral, compression),
│   │       │   check keeps; see upvc-door-wont-lock.
│   │       └─ Timber: deadbolt binding in keep. Check for swelling, dropped
│   │           hinges, keep position. Adjust keep or ease door; do not file the bolt.
│   │
│   └─ Key still won't turn with door open?
│       └─ LOCK OR CYLINDER FAULT. Continue.
│
├─ 2. Does the key go in fully?
│   ├─ NO ──> Obstruction. Look in the keyway with a torch. Snapped key tip?
│   │          Extract with hook/extractor. Damaged pin? Replace cylinder.
│   └─ YES ──> Continue.
│
├─ 3. Try a different key (spare, original not a copy).
│   ├─ Spare works ──> Key fault. Cut a new key from the ORIGINAL or by code.
│   └─ Spare also fails ──> Cylinder or mechanism. Continue.
│
├─ 4. Dry-lubricate (graphite/PTFE), insert and withdraw key several times, try.
│   ├─ Now turns ──> Dirt/wear. Advise replacement if stiffness returns.
│   └─ Still won't turn ──> Continue.
│
├─ 5. Does the key turn but do NOTHING (bolt doesn't move)?
│   ├─ YES, euro cylinder ──> Cam sheared or gearbox follower broken.
│   │      Remove cylinder: cam intact? → gearbox. Cam broken/loose? → cylinder.
│   └─ YES, mortice/rim ──> Lock case/cylinder internals. Replace lock or rim cylinder.
│
├─ 6. Key turns partway then stops hard?
│   ├─ Euro ──> Deadbolt or hooks jammed in the case. Remove cylinder, operate
│   │    gearbox with a follower/screwdriver via the cam slot. Moves? Cylinder
│   │    fault. Jammed? Gearbox fault.
│   └─ Mortice ──> Bolt jammed in case or against keep edge. Remove lock, test out of door.
│
└─ 7. Thumbturn works, key side doesn't (euro)?
    └─ Key side half of cylinder failed or key worn. Replace cylinder (upgrade to 3-star).

Alignment faults on uPVC and composite doors

Most calls. A uPVC door hangs on two or three flag hinges, each with cap-covered Allen adjusters for height (lifting the door), lateral position (moving it toward or away from the hinge jamb) and compression (pulling the door onto the seals). Over years the door drops a few millimetres and the hooks, rollers and deadbolt of the multipoint arrive low against their keeps. With the door closed, the mechanism is pre-loaded, so the key (which drives the deadbolt and often the hooks) cannot move it. Open the door and everything works.

Diagnose by marking the keeps: close the door, lift the handle, open it, and look for witness marks where the hooks have been striking the keep edges. Lift the door at the hinges in 1 mm increments (the hinge adjustment screws typically give 3–5 mm range) and test. Some systems have adjustable keeps as well (a cam or an eccentric roller); move them rather than the hinges where only one point is catching. Then check compression: a door compressed too hard against a swollen weatherseal also loads the mechanism. Full method is in upvc door wont lock. Twenty to forty minutes, no parts, and the customer's lock is fine.

Seasonal variation (locks in winter, not in summer, or the reverse) is the same fault with thermal movement added; adjust for the mid-point and reduce compression slightly.

Cylinder faults

A euro cylinder is a plug of five or six pin stacks (or a dimple, disc or sidebar system on high-security types) with a cam at the centre that drives the gearbox follower. It fails in predictable ways:

Measure before you buy: with the cylinder out, measure from the centre of the fixing screw hole to each end. Fit a cylinder that finishes flush with or within 3 mm of the handle or escutcheon; a cylinder protruding more than 3 mm is a snapping target. Upgrade to a TS 007 3-star or a Sold Secure Diamond cylinder; the £20–£40 premium over a basic cylinder is what the customer's insurer and the police would expect.

Gearbox and lock-case faults

If the cylinder is good (key turns the cam freely with the cylinder out of the door, or a known-good cylinder behaves the same way in the door), the fault is in the multipoint gearbox. Symptoms: the key turns the cam but the deadbolt does not move or moves and jams; the handle will not lift with the door open; the key turns 90° and stops dead. With the cylinder removed, operate the follower with a flat screwdriver through the cam slot: a gearbox that will not throw the bolt from the follower is broken internally (a snapped spring, a stripped gear or a sheared bolt tail). Replace the gearbox or the complete strip; identify the make by the markings on the faceplate, the backset (centre of the cylinder to the faceplate edge, usually 35 mm or 45 mm), the PZ dimension (handle centre to cylinder centre, commonly 92 mm) and the faceplate width. Full method in upvc door lock mechanism replacement.

A mortice sashlock or deadlock on a timber door fails similarly: a broken lever spring leaves a lever in the wrong position so the key will not pass; a worn bolt stump jams; a lock that has had the wrong key forced has a bent lever. Remove the lock (forend screws, then draw it out of the mortice) and test on the bench. A BS 3621 lock is not worth repairing; replace like-for-like on case size (typically 64 mm or 76 mm case, 44 mm or 57 mm backset) and keep spacing.

Rim cylinders and nightlatches

A rim cylinder (the round brass cylinder of a nightlatch) is held by two screws through the backplate and drives the latch via a flat tailbar. If the key turns stiffly or not at all, check first that the cylinder has not rotated in the door (loose backplate screws let the whole cylinder turn with the key, so the tailbar does not move the latch). Tighten the screws; if the tailbar is bent or too long, trim it to the manufacturer's length marks. A worn rim cylinder is a direct replacement; match the make if the nightlatch body is to stay, or replace the whole nightlatch with a BS 3621 model if it is the sole lock on a final exit door.

Timber door alignment

A timber door that will not lock in wet weather has swollen and the deadbolt is riding on the edge of the keep, loading the lock. Open the door: the key turns. Look at the keep for witness marks. Options: adjust the keep (move it 1–2 mm by plugging and re-drilling, or file the keep aperture, never the bolt), or ease and seal the door edge (a swollen door is an unsealed door; plane 1–2 mm from the leading edge and prime and paint all edges including the top and bottom). Dropped hinges with worn pins or loose screws are the other common cause; replace screws with longer ones into sound timber, or replace the hinges.

Preventing the callback

After any lock repair: dry-lubricate the cylinder (never oil), check and adjust the keeps and hinges so nothing is loaded with the door closed, check the cylinder protrusion, and cut any new keys from the original. Tell the customer to lubricate the cylinder once a year with graphite or PTFE, not oil or WD-40, and to stop using a key that has become stiff rather than forcing it.

Frequently Asked Questions

Why does the key work with the door open but not closed?

Because the lock is not the problem. With the door closed, the hooks, rollers or deadbolt are pressing against the keeps because the door has dropped, swelled or is being compressed too hard against the seals. That load prevents the key from moving the mechanism. Adjust the hinges and keeps on a uPVC or composite door, or ease and reseal a swollen timber door. Replacing the cylinder changes nothing.

Can I use WD-40 in a lock?

No. WD-40 is a water-displacing solvent that cleans and then dries to a thin gum; in a cylinder it attracts dust and eventually makes the pins stick worse. Use a dry graphite powder or a PTFE-based lock lubricant, a small puff into the keyway, then work the key in and out. Oil and grease are worse than WD-40 for the same reason.

What cylinder should I fit as a replacement?

For a uPVC or composite door, a TS 007:2014 Kitemark 3-star cylinder (or a 1-star cylinder with a 2-star security handle), or a Sold Secure Diamond cylinder, sized so it sits flush or within 3 mm of the handle. These resist snapping, drilling and bumping, satisfy Secured by Design and are what insurers expect on an external door. For a timber final exit door, the lock itself should be BS 3621:2017 (or BS 8621 where keyless internal egress is needed), and the insurer will usually ask for it by name.

The key snapped in the lock. Can I get it out without replacing the cylinder?

Often. Pull the broken piece out with a broken-key extractor or a fine jigsaw blade with the teeth facing outward, hooking the bitting. Do not push it further in and do not use superglue on the key stub. If it is deep, remove the cylinder and push it out from the cam end. Then ask why it snapped: a key that needed forcing was already telling you the cylinder was worn or the door was misaligned. Check the alignment and consider a new cylinder.

How much does a locksmith charge to fix a key that won't turn?

Expect a call-out of £65–£120 regionally (£90–£180 London) that covers diagnosis and simple adjustment. Hinge and keep adjustment is usually within the call-out. A replacement 3-star cylinder adds £35–£80 supplied and fitted; a BS 3621 mortice lock £40–£90 plus 1–1.5 hours; a multipoint gearbox £60–£150 plus 1–2 hours. Out-of-hours and lockout calls carry a premium of 50–100%.

Regulations & Standards