Summary

Gutter joints are the weak point of every rainwater system, and a dripping union is the most common guttering call-out after a blockage. The drip itself is a nuisance; the damage it does is not. Water falling from a joint for a few winters saturates the wall below, erodes pointing, soaks the fascia and soffit, and sets up penetrating damp inside. On a cavity wall it can bridge the cavity through debris on the wall ties; on a solid wall it is the start of a damp patch at skirting level.

Joints leak for a short list of reasons and it is worth separating them before quoting, because the fix ranges from a £3 seal to a new gutter run. A single joint dripping on a run that is otherwise sound is almost always a seal that has hardened or a union that has been pushed out of its seat by thermal movement. Several joints dripping, or joints that leak only in heavy rain, usually points to the gutter itself: brackets that have dropped so water stands in the joints, a fall that was never right, or a gutter run too long for the outlets so it overtops at the joints before it reaches the downpipe. Old plastic that has chalked and gone brittle will not hold a new seal for long, and old cast iron that has rusted through at the joint bolts needs sections replaced, not sealant.

This guide gives the diagnosis, the repair method for each gutter material, the fall and bracket spacing standards that stop the problem recurring, and the point at which replacement is the better answer. For overflow rather than joint leaks see gutters overflowing in heavy rain; for sizing see gutter downpipe sizing; for fall calculations see guttering fall gradient calculator.

Key Facts

Quick Reference Table

Diagnosed the problem? Create a repair quote in minutes with squote.

Try squote free →
Symptom Where it leaks Likely cause Fix
Steady drip from one union after rain stops Underside of union Hardened or displaced seal Replace seal or union; check insertion mark
Drip from union only in heavy rain Union, over the lip Water standing or backing up at joint Correct fall and brackets; check for downstream blockage
Several unions dripping along the run Multiple Gutter sagging between brackets; too few brackets Re-bracket at 1 m (800 mm exposed) and re-fall
Union has pulled apart, gap visible Joint open Gutter fixed hard home, no expansion allowance; or run slid downhill Refit to insertion marks; add bracket to hold position
Leak at stop end End of run Stop end unsealed, cracked or missing bracket Reseal/replace stop end; bracket within 150 mm
Leak at running outlet Around outlet body Seal failed; outlet undersized; fall away from outlet Replace outlet; check fall direction
Leak at corner angle Angle union Angle fixed without brackets each side; seal failed Brackets within 150 mm of angle each side; new angle
uPVC chalky, cracked at clips, leaks at several joints Everywhere UV degradation, end of life Replace run
Cast iron drip at bolted joint, rust stains Joint Bedding compound failed, bolt rusted Dismantle, clean, remake with mastic and new bolt
Cast iron weeping from body near joint Metal Rusted through, often at the back edge Replace section
Water behind gutter running down fascia Between gutter and fascia Gutter too far from roof edge; drip edge/felt missing or short Fit eaves protector/felt support tray; reposition gutter
Downpipe "joint" leaking Socket of downpipe Blockage below; shoe/offset off its spigot Clear blockage; refit joint

Detailed Guidance

Diagnosis: find where the water actually comes from

GUTTER JOINT LEAK — DIAGNOSIS
│
├─ Watch it in rain, or run a hose into the gutter upstream of the joint.
│
├─ Does it drip from UNDER the joint with water flowing normally past?
│    → Seal failure or joint displaced.
│       ├─ Is the gutter pushed past the insertion mark? → thermal lock, refit.
│       ├─ Seal hard/shrunk/missing? → new seal or union.
│       └─ Gutter and union from different systems? → mismatch; use correct part.
│
├─ Does water STAND in the gutter at the joint?
│    → Fall or bracket problem.
│       ├─ Sight along the gutter. Dips between brackets? → re-bracket.
│       ├─ Fall away from or level to the outlet? → re-fall whole run.
│       └─ Downstream blockage holding water back? → clear it first.
│
├─ Does it leak only in heavy rain, overtopping the joint?
│    → Capacity: run too long, outlet undersized, or roof area too big.
│       → See gutters-overflowing-in-heavy-rain. Add outlet/upsize.
│
├─ Is water running BEHIND the gutter down the fascia?
│    → Not a joint leak. Roof edge detail: felt/underlay stopping short,
│       no eaves protector, gutter set too low or too far out.
│
└─ Is the plastic chalky, brittle, cracked at brackets, 15+ years old?
     → Seal replacement will not last. Recommend replacement.

Run a hose and watch. Customers describe a leak as "at the joint" when the water is actually overtopping the back edge upstream, running behind the gutter and dropping off at the joint because that is where the fascia line breaks. Look at the fascia for a tide mark or green staining above the leak, which is the sign of water getting behind rather than through.

Repairing uPVC joints

  1. Identify the system. Look for the manufacturer's name moulded into a bracket or union, and the profile and size (112 mm half-round, 114 mm square, 115 mm deep-flow, 125 mm ogee are the common ones). Take a photo of the clip shape for the merchant. Mixed systems are the single biggest reason a "new seal" keeps leaking.
  2. Release the union. Unclip the retaining clips on both sides. If the gutter has been forced hard home, warm the union gently with a hot-air gun to free it, or cut the gutter back 10 mm either side with a fine-toothed saw and fit a new union with the correct insertion depth.
  3. Clean the gutter ends. Scrape off moss, grit and old sealant residue. A rough or scored gutter end will not seal. Check the end is cut square; a gutter cut on the skew seals on one side only.
  4. Fit the new seal or union. A new union is often as cheap as a seal and comes with new clips. Apply the manufacturer's silicone lubricant to the seal if their instructions say so. Push the gutter in only to the insertion mark, never to the stop.
  5. Bracket it. There should be a bracket within 150 mm of the union on each side. If there is not, add them; a union carrying the weight of two unsupported gutter ends will twist and leak.
  6. Check the fall. Sight along the run from the stop end. The gutter should fall steadily to the outlet with no dips. Dips are brackets that have dropped: re-screw with 40 mm stainless screws into the fascia, or move the bracket a few millimetres if the fixing has lost grip. Use a string line pulled taut from the high point to the outlet, set 3 mm per 1.8 m, and fix brackets to it.

Do not seal a uPVC union with silicone or mastic. It fails within a season because the joint moves, and it makes the next proper repair harder. If a seal cannot be sourced and the union is discontinued, replace the union with a universal adaptor or replace the run.

Repairing cast iron joints

Cast iron gutters joint with an overlap of about 50 mm, a bedding compound between the surfaces, and a single gutter bolt through the overlap with the head inside and the nut below. The compound fails first, then water sits in the joint and rusts the bolt and the gutter metal around it.

  1. Support the gutter either side and remove the bolt; it will usually need cutting with a hacksaw or a small grinder and drilling out.
  2. Separate the joint and clean both surfaces back to bare metal with a wire brush and scraper. Check for rust perforation around the bolt hole and along the back edge, which is where cast iron fails; if the metal is holed, the section is replaced, not sealed.
  3. Prime bare metal with a zinc-rich or red-oxide primer and let it dry.
  4. Apply a bead of non-setting gutter mastic or lay a butyl mastic strip around the bolt hole and across the full width of the lap, and reassemble with a new M6 × 25 mm stainless or galvanised gutter bolt, head inside, with a sealing washer. Tighten until the compound squeezes out, then clean off the excess.
  5. Repaint the inside of the gutter with a bitumen gutter paint or a suitable metal paint once the joint has set.

Cast iron sections in ogee, half-round and moulded profiles are still manufactured to traditional patterns, and cast aluminium replicas are available for runs where the weight is a problem. On a listed building cast iron is usually required to be replaced like for like.

Aluminium, steel and GRP

Proprietary aluminium systems joint with a factory union and gasket much like uPVC and are repaired the same way, using the manufacturer's parts; most are not compatible with each other. Seamless aluminium is roll-formed on site in one length and has joints only at corners, outlets and stop ends, which are riveted and sealed with a high-grade neutral-cure silicone or a polyurethane sealant. A leaking seamless corner is cleaned, the old sealant removed completely, dried, and resealed; a corner that leaks repeatedly usually has a rivet that has worked loose and needs replacing. Steel and GRP systems use clips with gaskets or sealants specified by the manufacturer, and the data sheet should be followed because some sealants attack the coating.

When to stop repairing and replace

A gutter run is a candidate for replacement rather than repair when:

On a typical semi-detached house a complete uPVC replacement front and rear, with new brackets at 1 m centres, correct fall and new downpipes, is a day's work for two and removes the problem for 20–25 years. Re-sealing six joints one at a time over three visits can cost the customer more and leave them with the same old gutter.

Getting the fall right

A 1:600 fall is 3 mm in 1.8 m, 10 mm in 6 m, or about 17 mm in 10 m. Set the outlet bracket first at the lowest point that still clears the roof-edge drip, then the stop-end bracket at the high point, pull a string line between them, and fix the intermediate brackets at 1 m centres to the line. On a long run with a single end outlet, check the high end still catches the roof water: a tiled roof with a 100 mm overhang throws water further than a slate roof with a tight edge. If the fall needed would lift the high end above the drip line, split the run with a centre outlet or two end outlets and fall to both. Keep the gutter front edge about 25 mm below the line of the roof slope extended, so wind-driven water does not skip over the front lip.

Frequently Asked Questions

Can I seal a leaking uPVC gutter joint with silicone?

It is a temporary measure at best. The joint is designed to move with thermal expansion, and a rigid bead of sealant cracks within a season; the sealant also sticks to the seal seat and makes a proper repair harder. If the customer needs a stop-gap before a replacement, a self-adhesive gutter repair tape over the joint will usually hold for a winter. The proper repair is a new seal or union fitted to the insertion mark with a bracket each side.

Why does the joint keep pulling apart even after I refit it?

Either the gutter was pushed fully home against the stop so it has no room to expand, so on a hot day it pushes the union along and on a cold night it pulls out, or the run is sliding downhill because there is no bracket holding the gutter near the joint and the brackets are only clipping the gutter rather than gripping it. Fit the gutter to the insertion mark (it is usually a moulded line or arrow inside the union), and fit a bracket within 150 mm each side. Some systems have a notch or a fixing bracket designed to hold one point of the run in place; use it.

The gutter is new and already leaking at the joints. What went wrong?

Nearly always one of three installer errors: gutter pushed fully home with no expansion allowance; brackets too far apart so the gutter sags and water stands at the joints; or mixed components from two systems that do not seal to each other. Occasionally the gutter ends were cut with a coarse blade and left ragged, or the ends were cut on the skew. Fix the installation fault; the seals themselves are rarely defective from new.

How many brackets does a gutter need?

One every metre on standard uPVC half-round and square profiles, every 800 mm on exposed sites and for deep-flow, ogee and heavier profiles, and one within 150 mm of every union, outlet, angle and stop end. Cast iron and aluminium follow the manufacturer's spacing, commonly 900 mm–1 m. A 6 m uPVC length with a union at each end therefore has at least seven brackets, not the three or four that are commonly found.

Does a leaking gutter joint cause damp inside?

Yes, and it is one of the commonest causes of penetrating damp at high level and of a damp patch at skirting level on the same wall. Water running down the wall from a leaking joint saturates the brickwork, washes out pointing and tracks through cracks and ties. Fix the gutter first, then allow the wall several months to dry before any internal redecoration. See penetrating damp.

Regulations & Standards