Demolition Vibration Monitoring: PPV Limits Under BS 7385, Plant Selection and Neighbour Notification
BS 7385-2:1993 PPV limits (3 mm/s residential, 6 mm/s robust, 12.5 mm/s industrial); BS 5228-2:2009 framework; continuous vs triggered geophone monitoring; Trigger Action Levels; plant selection by vibration output; pre-demolition Schedule of Condition survey