Door Frame Installation: Lining Sets, Packing & Plumb/Level Checks

Quick Answer: A door lining set consists of two legs and a head, typically 32mm or 38mm thick and 95mm or 138mm wide to suit standard 100mm or 140mm partition wall thicknesses. The lining must be set plumb, level, and square — the door will only hang correctly and close reliably if the lining is accurate. Fix using 100mm screws into the rough frame or studs, packing behind the lining at each fixing point to achieve plumb.

Summary

Door frames and linings are among the most important second-fix carpentry items. A door that sticks, binds, swings open on its own, or won't latch properly almost always traces back to a lining that was not set accurately. Getting the lining right before the door is hung eliminates 90% of door problems — and rehinging a door on a bad lining is a frustrating, time-consuming exercise.

The terminology varies by trade. A lining (or lining set) is the timber surround inside a partition or studwork wall opening — it has no external rebate and accepts a separate stop bead. A frame (or door frame) has an integral rebate moulded in and is typically used for external doors or internal fire doors where a solid rebated frame is required for gasket or intumescent strip installation. Most internal domestic doors go into linings; external and fire doors go into frames.

The door width and height determine the opening size but the lining sets the finished aperture. Understanding the relationship between rough opening, lining size, and finished door size is fundamental. Getting the rough opening wrong means re-trimming the opening — far more work than getting it right first time.

Key Facts

Quick Reference Table

Spending too long on quotes? squote turns a 2-minute voice recording into a professional quote.

Try squote free →
Standard Door Size Nominal Width Nominal Height Typical Wall Lining Width
Narrow internal 610mm (2') 1981mm 95mm for 100mm wall
Standard internal 686mm (2'3") 1981mm 95mm for 100mm wall
Standard internal 762mm (2'6") 1981mm 95mm for 100mm wall
Standard internal 838mm (2'9") 1981mm 95mm for 100mm wall
Wider internal / accessible 826mm 2040mm 108mm for 125mm wall
External door (UK standard) 838mm 1981mm Frame (rebated), not lining
Wall Construction Wall Thickness Required Lining Width
75mm stud + 2 × 12.5mm board 100mm 95mm (trim or shim if exact)
100mm stud + 2 × 12.5mm board 125mm 120mm
100mm block + 12mm plaster 112mm 108mm
215mm brick (full) + 12mm plaster each side 239mm 235mm (or deep lining + extension)

Detailed Guidance

Sizing the Rough Opening

Before framing the rough opening in a stud wall, calculate the correct size.

Width calculation:

Height calculation:

Frame the opening using king studs and trimmer studs (see stud walls). Always fit a header over the opening — a doubled 47×100mm minimum for stud wall openings.

Fitting the Lining Set

Step 1 — Prepare the opening:

Step 2 — Assemble the lining:

Step 3 — Set and fix:

Step 4 — Finish:

Hanging the Door

With the lining set plumb and square:

  1. Plane the door to fit the opening with correct clearances (2mm each side, 3mm top, 5–10mm bottom)
  2. Mark hinge positions on the door — standard positions are 150mm from the top and 225mm from the bottom (to centre of hinge knuckle)
  3. Mark corresponding positions on the hinge leg of the lining — ensure the door marks and lining marks are at the same height
  4. Cut hinge recesses to the exact hinge leaf thickness — recesses must be exactly right. Too deep, and the door binds on the hinge side; too shallow, and the door binds on the latch side
  5. Fix hinges to door first, then offer up and fix to lining
  6. Check operation — door should swing freely and remain stationary when released at any angle (not swing open or close on its own, which indicates the lining is out of plumb)
  7. Mark and fit the lock/latch and strike plate last

Fire Door Linings and Frames

Fire doors (FD30, FD60) must be hung in a solid frame with intumescent seals. Requirements:

External Door Frames

External door frames differ from internal linings:

Frequently Asked Questions

What causes a door to swing open or closed on its own?

The lining is out of plumb. If the hinge leg of the lining leans backward (top away from the room), the door will swing open. If it leans forward (top into the room), the door will swing closed. Check the hinge leg with a long spirit level. Another cause is hinges that are recessed to different depths — unequal recesses tilt the door face relative to the lining.

My door keeps dropping and binding at the bottom — what has gone wrong?

The screws in the top hinge have pulled out. This is usually a fixings problem — screws into thin door stiles or into the lining timber at the wrong depth. Refit with longer screws (50mm into door stile, 50mm into lining). On a heavy door, fit a third hinge.

Should I fit the lining before or after plastering?

Either approach works, with different requirements. Fitting before plastering means the lining acts as a screed guide and the plaster is brought up to the lining face — neater result but the lining must be protected during plastering. Fitting after plastering allows the plaster to dry completely and gives a clean reference surface — the lining face is set flush with or just proud of the plaster. Both methods are used in practice.

What size lining do I need for a 100mm stud wall with 12.5mm plasterboard?

A 100mm stud wall with one layer of 12.5mm plasterboard each side gives a total wall thickness of 125mm. A standard 120mm lining is a near match but will sit 5mm proud of the plaster face on each side — these can be left as a shadow reveal or covered with a narrow scribing strip. A custom 125mm lining is the ideal fit. Check with your supplier for the nearest available width.

Can a fire door be fitted in a standard softwood lining?

No — fire doors must be fitted in frames that form part of an approved tested combination (door + frame + hardware). Most FD30 fire door manufacturers specify solid hardwood or engineered timber frames. Using a standard softwood lining with a fire door invalidates the fire rating and would fail a Building Control inspection.

Regulations & Standards